Page 2 - WARNING
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to pre...
Page 3 - This Manual is Designed to Make it as Easy as Possible for You to; Tools Needed for Assembly; Installed Wire Length; Unpacking Instructions
3 THE FAN MODELS CF244BS, CF244CRM, CF252BS & CF252CRM ARE SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. THE FAN MODELS CF244WW, CF244ORB, CF252WW & CF252ORB ARE SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, ...
Page 5 - General; Figure 1; Figure 2
5 Your new ceiling fan will require agrounded electrical supply line of 120 voltsAC, 60 Hz, 15 amp circuit. The outlet box must be securely anchoredand capable of withstanding a load of atleast 50 pounds. General Your Emerson ceiling fan comes suppliedwith a Fan/Light Remote Control whichconsists of...
Page 6 - Figure 5; Figure 4
6 UL Model No.: CF244 & CF252 11. Carefully turn the partially assembledceiling fan right side up and place thefan securely into the packingstyrofoam in preparation for finalassembly. 12. Remove the hanger ball by looseningthe setscrew in the hanger ball untilthe ball falls freely down the downr...
Page 7 - Figure 6
7 UL Model No.: CF244 & CF252 SETSCREW CLEVIS PIN MOTORCOUPLING DOWNROD HAIRPINCLIP DOWNROD HAIRPINCLIP MOTORCOUPLING SETSCREW (2) CLEVIS PIN Figure 6 HAIRPIN CLIP CLEVIS PIN MOTORCOUPLING COUPLERCOVER SETSCREW (2) Figure 7 14. While pulling up on the downrod,securely tighten the two setscrews i...
Page 8 - Figure 9
Turning off wall switch is not sufficient.To avoid possible electrical shock, besure electricity is turned off at the mainfuse box before wiring. All wiring must bein accordance with National and Localcodes and the ceiling fan must beproperly grounded as a precautionagainst possible electrical shock...
Page 11 - Your cover plate is now installed
1. Screw in two 50-watt (maximum)halogen mini candelabra base bulbs inthe light kit plate sockets (Figure 15). 50-WATT (maximum) HALOGEN MINI CANDELABRA BASE BULBS (2) LIGHT KIT PLATE SOCKETS (2) Figure 15 2. Place the glass shade into the openingin the fan motor housing assembly,aligning the three ...
Page 12 - TO INSTALL BRACKET TO WALL:
12 UL Model No.: CF244 & CF252 General Your Emerson Ceiling Fan/Light RemoteControl consists of hand-held transmitterand a receiver which is mounted under thefan ceiling cover. The remote control isdesigned to separately control your ceilingfan speed and light intensity. The remote control trans...
Page 14 - Fan/Light Fails to Operate; • Check that the speed switch on the; Short Range; • If the remote control operates the fan; Remote Control; IMPORTANT CARE INSTRUCTIONS
UL Model No.: CF244 & CF252 14 Fan/Light Fails to Operate • Check that the speed switch on the fan is set to HIGH (....) speed. • Check that the light switch is on.• Check that the battery is good (red indicator light should light whenany button is pressed). • Check that the receiver is wired pr...
Page 15 - Ceiling Fan Trouble Shooting; TROUBLE; Make sure; FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX
UL Model No.: CF244 & CF252 15 Ceiling Fan Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line 2. Check line ...
Page 16 - Repair Par ts Listing
16 UL Model No.: CF244 & CF252 Damp Part Numbers Wet Part Numbers Key Model No. Model No. Model No. Model No. Model No. Model No. Model No. Model No. No. Description CF244BS00 CF252BS00 CF244CRM00 CF252CRM00 CF244WW00 CF252WW00 CF244ORB00 CF252ORB00 * Hanger Pack Consisting of: 761655-17 761655-...
Page 17 - Repair Par ts; HOW TO ORDER REPAIR PARTS
17 UL Model No.: CF244 & CF252 Repair Par ts 7 16 12 15 23 22 21 14 13 10 - 52" 11- 44" 1 20 9 18 19 5 8 6 17 3 2 4 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: T...
Page 18 - INSTRUCTION TO THE USER (if device contains a digital device); Reorient or relocate the receiving antenna.
18 UL Model No.: CF244 & CF252 INSTRUCTION TO THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digitaldevice, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against har...
Page 19 - LIMITED WARRANTY; authorized service center.
19 UL Model No.: CF244 & CF252 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan againstall defects in workmanship and materials. You must be the original purchaser or user of the product to becovered. W...
Page 20 - Air Comfort Products; DIVISION OF EMERSON ELECTRIC CO.
UL Model No.: CF244 & CF252 Part No. F40BP74080000 Printed in China 01/10 Form No. BP7408 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 BP7408 44" & 52" Curva 1/12/10 8:52 AM Page 20