Page 2 - DANGER; ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!; About This Document; Date
CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not becompatible with process composition andoperating conditions. Applicationcompatibility is entirely the responsibilityof the user. DANGER HAZARDOUS AREA INSTALLATION This sensor is not Intrinsically Safe. or Explosi...
Page 3 - COMBINATION pH/ORP SENSOR; TABLE OF CONTENTS; Section Title
i MODEL 396P and 396PVP TABLE OF CONTENTS MODEL 396P and 396PVP COMBINATION pH/ORP SENSOR TABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICATIONS ................................................................. 1 1.1 Features and Applications............................................
Page 4 - LIST OF FIGURES; Number Title
MODEL 396P and 396PVP TABLE OF CONTENTS LIST OF FIGURES Number Title Page 1-1 Cross Section Diagram of the TUpH Patented Reference Technology ............................................................................... 2 2-1 Dimensional Drawing .......................................................
Page 5 - pH glass formulations exceed; DESCRIPTION AND SPECIFICATIONS; FEATURES AND APPLICATIONS
Model 396PVP is offered with a watertight sensor-to-cable connector which eliminates re-wiring and cabletwisting when replacing sensors. The Variopol VPmultiple pin connector is an integral part of each sen-sor model and uses a mating VP cable. Once thecable is installed and wired to the analyzer, s...
Page 6 - GPLR hemi or flat glass; pH range
2 MODEL 396P and 396PVP SECTION 1.0 DESCRIPTIONS AND SPECIFICATIONS Measurements and Ranges *pH: 0-14ORP: -1500 to 1500 mv Available pH A CCU G LASS Types GPLR hemi or flat glass Wetted Materials Titanium, Polypropylene, EPDM, glass; platinum (ORP only) Process Connection 1 in. MNPT front and rear f...
Page 7 - ORDERING INFORMATION; The Model 396P Sensor; is housed in a molded reinforced polypropylene; TABLE 1-1. RECOMMENDED ACCESSORIES FOR FIRST TIME INSTALLATIONS
3 MODEL 396P and 396PVP SECTION 1.0 DESCRIPTIONS AND SPECIFICATIONS 1.3 ORDERING INFORMATION The Model 396P Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suitable for insertion, submersion or flowthrough installation. The sensor includes a general purpose pH elec...
Page 8 - Examples of all sensing tip offerings; OTHER ACCESSORIES FOR MODELS 396P AND 396PVP
4 MODEL 396P and 396PVP SECTION 1.0 DESCRIPTIONS AND SPECIFICATIONS Optional Slotted Tip is available on all hemi bulb sensors, ordered as option -41 Flat Tip is avail- able with flat glass bulb sen- sors Examples of all sensing tip offerings Shrouded Tip is standard on all hemi bulb sensors Variopo...
Page 9 - INSTALLATION; Do not install the sensor upside down.; NOTE
5 MODEL 396P and 396PVP SECTION 2.0 INSTALLATION SECTION 2.0 INSTALLATION 2. Do not install the sensor on the horizontal. Thesensor must be 10° off the horizontal to ensureaccuracy. 3. Do not install the sensor upside down. 4. Air bubbles may become trapped in the sensor endbetween the glass bulb an...
Page 11 - Not for use with Model 396PVP.; Reducing
MODEL 396P and 396PVP SECTION 2.0 INSTALLATION FIGURE 2-4. Model 396P with Insertion Mounting Adapter (PN 23242-02). Not for use with Model 396PVP. Mounting adapter allows for sensor removal without twisting or disconnecting interconnecting cable for ease of maintenance. WHEN INCH AND METRIC DIMS AR...
Page 22 - FIGURE 4-8. Wiring Details for Models 396PVP
18 MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-8. Wiring Details for Models 396PVP or 396P-02-50 with Mating Variopol Cable (PN 23645-06) for use with Remote Junction Box (PN 23309-03) to Model 1181 FIGURE 4-7. Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol ...
Page 23 - FIGURE 4-14. Wiring Details for Models 396PVP or
MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-12. Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Remote Junction Box (PN 23555-00) to Models 3081, 4081, & 5081 FIGURE 4-11. Wiring Details for Models 396PVP or 396P- 02-54 wi...
Page 25 - FIGURE 4-18. Wiring Details for Models 396PVP; with Variopol
MODEL 396P and 396PVP SECTION 4.0 WIRING - MODEL 396PVP FIGURE 4-18. Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-06) for use with Models 1054A/B & 2054 FIGURE 4-19. Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-06) for...
Page 28 - SENSOR PREPARATION; START UP AND CALIBRATION
1. While obtaining a process solution sample (it is recommended that the sample is taken close to the sensor), record the pH value thatis shown on the analyzer/transmitter display. 2. Measure and record the pH of the process solution sample with another temperature compensated, calibrated pH instrum...
Page 29 - MAINTENANCE
25 MODEL 396P and 396PVP SECTION 6.0 MAINTENANCE The Model 396P and 396PVP Sensors require mini-mum maintenance. The sensor should be kept cleanand free of debris and sediment at all times. The fre-quency of cleaning by wiping or brushing with a softcloth or brush is determined by the nature of the ...
Page 30 - One type of commonly used ORP standard; CAUTION; A second ORP standard solution is the Ferric-
26 MODEL 396P and 396PVP SECTION 6.0 MAINTENANCE 6.3 MODEL 396P and 396PVP ORP 4.3.1 Platinum Electrode Check. The platinum elec- trode may be checked as follows: There are two typesof standard solutions which may be used to check theORP electrode/transmitter system. Type 1: One type of commonly use...
Page 31 - DIAGNOSTICS AND TROUBLESHOOTING; DESCRIPTION OF PROBLEM
27 MODEL 396P and 396PVP SECTION 7.0 DIAGNOSTICS AND TROUBLESHOOTING SECTION 7.0 DIAGNOSTICS AND TROUBLESHOOTING 7.1 MODEL 54e/81/3081/4081/5081/Xmt DIAGNOSTICS AND TROUBLESHOOTING The Model 54 Analyzer and Models 81 and 3081 Transmitters automatically search for fault conditions that wouldcause an ...
Page 32 - TROUBLESHOOTING WITHOUT ADVANCED DIAGNOSTICS.; Problem
28 7.2 TROUBLESHOOTING WITHOUT ADVANCED DIAGNOSTICS. Table 7-2, below, lists common problems, causes and remedies typically encountered in process measurement. Problem Probable Cause Remedy Meter reads off scale. (Display Defective preamplifier Replace preamplifier (for code 02 reads overrange). sen...
Page 34 - RETURN OF MATERIAL; Call Rosemount Analytical for authorization.
30 MODEL 396P and 396PVP SECTION 8.0 RETURN OF MATERIAL SECTION 8.0 RETURN OF MATERIAL 8.1 GENERAL. To expedite the repair and return of instruments, prop-er communication between the customer and the fac-tory is important. Before returning a product forrepair, call 1-949-757-8500 for a Return Mater...
Page 35 - The shipping container should be marked:
WARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller, and that the Goods manufacturedor Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expira-tion of the applicable warranty peri...
Page 36 - Specifications subject to change without notice.
Credit Cards for U.S. Purchases Only. The right people,the right answers,right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. Emerson Process Management Liquid Division 2400 Barranca ParkwayIrvine, CA 92606 USATel: (949) 75...