Summary

Page 2 - SPECIFICATION; Seconds; INSTALLATION; REMOVING THE OLD CONTROL; NOTE

2 SPECIFICATION ELECTRICAL RATINGS: Input and Frequency: 120 VAC, 60 Hz Output Ratings: Ignitor Load: 2 Amps maximum Inducer Draft Motor: 3 Amps Full Load, 4 Amps Locked Rotor Current: 0.2 Amps @ 120 VAC Range of Regulation (Btu/Hr) Minimum: 30,000 Maximum: 150,000 1.0” Pressure Drop Capacity a 100,...

Page 3 - OPERATING INSTRUCTIONS; Figure 1. Typical gas connection; TEMPERATURE REGULATION; Figure 2. Temperature Indicators and Adjustment

3 GROUND JOINT UNION INTELLI-VENT™ CONTROL GAS SUPPLY PIPE TEE DRIP LEG (SEDIMET TRAP) 3" MINIMUM (MANDATORY) PIPE CAP SHUT-OFF VALVE 8. Open the gas shutoff valve.9. BEFORE TURNING ON THE APPLIANCE, CHECK THE GAS LINES FOR LEAKS. a. Use a soapy water solution. DO NOT test for gas leaks using a ...

Page 4 - WARNING; SHUTTING OFF THE APPLIANCE; Vacation Shutdown

4 Table 1. Temperature Settings Display A B C Approximate Temperature ( +10 o F) Approximate Time to Cause Injury 70 (Vacation) N/A 110115120 5 minutes 125130 30 seconds 135140 5 seconds 145150 1.5 seconds 160 under 1 second Flashing WARNING ! Never allow small children to use a hot water tap, or to...