Page 2 - Gas Valve Cross Reference; Index; Product Features and Specifications; WRMobileTM provides instant access to product; Emerson Climate Technologies Mobile Toolbox; For complete online; Online Cross Reference
2 Gas Valve Cross Reference Index Gas Valve Selection Guide ................................................. 3 Range of Operation ............................................................ 5Nomenclature ..................................................................... 6 36C .....................
Page 3 - Gas Valve Selection Guide; What questions need to be asked when matching up; Standing Pilot; Pipe Size Both Inlet and Outlet; SINGLE; Direct Spark
Gas Valve Cross Reference 3 ► Gas Valve Selection Guide What questions need to be asked when matching up gas valves?1. Type of Valve 1.1 Standing Pilot 1.2 Intermittent Ignition (Proven/Intermittent Pilot) 1.3 Direct Burner Ignition (Spark or Hot Surface) 1.4 Single Stage 1.5 Two-Stage 2. Pipe Size ...
Page 5 - Range of Operation; 6H 36J
Gas Valve Cross Reference 5 ► Range of Operation 36C 36H 36J Applications Natural Gas Range of Regulation Opening Characteristic Fast Open Slow Open Step Open Fast Open Slow Open 2-Stage Fast Open 2-Stage Slow Open Fast Open Slow Open 2-Stage Fast Open 2-Stage Slow Open 1/2" x 3/8" 1/2" ...
Page 6 - XX; VOLTAGE LETTER CODING; TYPE NUMBER; Nomenclature
6 Gas Valve Cross Reference 36C XX X - XXX Basic Model Number Series Specification of options/features (numbered versions) VOLTAGE LETTER CODING LETTER VOLTAGE FREQUENCY CURRENT NONE AB CGHU 1XX2XX3XX4XX 1 ⁄ 2 ” x 3 ⁄ 8 ” 1 ⁄ 2 ” x 1 ⁄ 2 ” 1 ⁄ 2 ” x 3 ⁄ 4 ” 3 ⁄ 4 ” x 3 ⁄ 4 ” 24 120 115 24 240240 .75...
Page 7 - XXX
Gas Valve Cross Reference 7 Model Number 36H2236H2336H3236H3336H5436H5536H6436H65 Fast Ope n Slow Ope n Direct Ignition Proven Pilot Single Stage Two Stage FEATURES X X X X X X X X XX XX XX XX XXXX XXXX 36H XX X - XXX TYPE NUMBER CODING Number Pipe Size (inlet x outlet) 4XX3XX2XX 3/4" NPT x 3/4&...
Page 8 - System Applications; Typical Wiring for Hot Surface Ignition System
8 Gas Valve Cross Reference Hot Surface Ignition (HSI) The thermostat calls for heat and energizes the HSI control. If system is equipped with prepurge, the purge fan is energized and power will be delayed thirty seconds before application to the Hot Surface Ignitor. If prepurge is not selected, the...
Page 9 - Gas flow to the pilot burner is controlled by a safety valve which; Proven Pilot; Flame is sensed by the flame detection circuit which energizes; Typical Wiring for Proven/Intermittent Pilot System
Gas Valve Cross Reference 9 Standing Pilot Gas flow to the pilot burner is controlled by a safety valve which is manually operated and held in by current generated from a thermocouple placed in the pilot flame. When the thermostat calls for heat the main valve is energized. Proven Pilot The thermost...
Page 10 - Cycle Pilot System; solenoid and pilot relight control. Pilot valve opens and relight; CYCLE PILOT HARNESSES
10 Gas Valve Cross Reference Cycle Pilot System The thermostat calls for heat and simultaneously energizes pilot solenoid and pilot relight control. Pilot valve opens and relight begins sparking. Gas flow activates the pressure switch. Sparks ignite pilot gas. Once the flame is detected, the sparks ...
Page 11 - Features
Gas Valve Cross Reference 11 36C Series Combination Gas Valve. The versatile 36C03 Series combination gas valves cover a wide range of applications. Designed for use with common ignition systems and standing pilots, it replaces hundreds of existing models in the field. Features • Standing Pilot • Ad...
Page 12 - • Inlet/outlet screens; Specifications
12 Gas Valve Cross Reference 36H Series Universal Replacement Electronic Ignition Gas Valve. The versatile 36H Series combination gas valves cover a wide range of applications. Designed for use with common ignition systems (HSI/DSI/Proven Pilot), it replaces hundreds of existing models in the field....
Page 14 - /4” brass compression fitting for pilot line conver; ACCESSORIES; Product Accessories
14 Gas Valve Cross Reference 36C Series 36H Series 36J Series ACCESSORIES Model Number Regulator Conversion Kits F92-0659 Natural Gas to LP Single Stage F92-1008 Natural Gas to LP Two-Stage F92-0656 LP to Natural Gas Single Stage F92-1011 LP to Natural Gas Two-Stage ACCESSORIES Model Number Regulato...
Page 15 - Cross Reference
Cross Reference OEM NO. WR NO. Gas Valve Cross Reference 15 OEM NO. WR NO. OEM NO. WR NO. ► Cross Reference 00 880208 36C03A-410 00 880209 36C03A-410 00001005570 36H32-304 00001008753 36J24-214 00001160253 36C03-433 00001162470 36C94-303 00001585980 36H32-304 0002-42-013 36C03U-333 0002-42-015 36C01...