Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Rosemount 3095FC MultiVariable Mass Flow Transmitter The products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualified products in applications that require ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Table of Contents SECTION 1Introduction 3095FC Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Section 1 Introduction 3095FC Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-13095FC Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-4Consideratio...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 1-4 Low Power Mode Sleep mode is used to place the CPU in a low power mode. The battery voltage is monitored by low voltage detection circuitry and the low voltage limit value is set at 5.4 volts. During Sleep mode, sub-modules a...
1-5 Rosemount 3095FC Reference Manual 00809-0100-4832, Rev AAOctober 2004 Instantaneous Rate Calculations The instantaneous value of the IV is used with the previous calculation period of the Integral Multiplier Value (IMV) to compute the instantaneous flow rate. The IMV is defined as the value resu...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Section 2 Installation Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page ...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 2-2 INSTALLATION Rosemount 3095FC Piping from the static and DP meter runs connect to female ¼-18 NPT connections. The 3095FC is an upstream device, meaning that the SP line normally connects to the high pressure side (labeled “H...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-3 Rosemount 3095FC 9. Calibrate the 3095FC (see “Calibrate” on page 4-1). 10. Connect the 3095FC unit to any other external communication devices or networks. 11. Place the meter run in service and monitor with Rosemount User Interface Software ...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 2-4 supplies significantly more than 1 Amp to the 3095FC. The maximum input is 28 volts. Do not allow the batteries to fully discharge. If the batteries are fully discharged, the battery charger board may enter thermal limiting. ...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 2-6 Communications Wiring The communication ports located on the 3095FC provide a data link to the Rosemount User Interface Software, other 3095FC units, and host systems. NOTE All communication ports for the 3095FC are located o...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-7 Rosemount 3095FC Table 2-3. Local Operator Interface Port Wiring Table 2-4. PC Comm Port Wiring EIA-485 (RS-485) Serial Communications - Comm 1 Use Comm 1 to monitor or alter the 3095FC from a remote site using a host or Rosemount User Interfa...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 2-8 Table 2-6. Communications Card Signals Table 2-7. EIA-232 (RS-232) Communications Card Wiring Ground the Transmitter Grounding reduces the effects of electrical noise on the unit's operation and protects against lightening. T...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-9 Rosemount 3095FC Pipelines Without Cathodic Protection The pipeline may provide an adequate earth ground and the 3095FC could mount directly on the meter run using an orifice plate. Use a ground system tester to make sure the pipeline to earth...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-11 Rosemount 3095FC INSTALL THE ROSEMOUNT USER INTERFACE SOFTWARE If a previous version of the Rosemount User Interface Software is installed, refer to “Uninstalling the Rosemount User Interface Software” on page 2-12. Software Overview The Rose...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-12 Rosemount 3095FC Install Without Autorun 1. Insert the Rosemount User Interface Software installation CD-ROM. 2. Click the Windows Start button. 3. Select Run. 4. Click the Browse button 5. Navigate to and select the Select.exe located on the...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-13 Rosemount 3095FC ESTABLISHING COMMUNICATION Connection Methods When the user is logged into the Rosemount User Interface Software, the PC must connect to the 3095FC unit so communication can be accomplished. Use one of the following connectio...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-14 Rosemount 3095FC Connect When off-line, the 3095FC menu displays Connect. To use Connect: 1. Physically connect the 3095FC (see “Installation” on page 2-2). 2. Launch and log into Rosemount User Interface Software (see “Getting Started with t...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-15 Rosemount 3095FC NOTE Double-click the desired communications link (3095FC name) to connect to that 3095FC. Double-clicking an icon is the same as selecting the menu bar or toolbar button Direct Connect or Connect commands. Configuration of t...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 2-16 Rosemount 3095FC Adding a 3095FC transmitter 1. Right-mouse click on the Device Root directory icon. 2. Select Add a Device . 3. Right-mouse click on the New Device and select Rename. Type in the new device name. 4. Press <Enter>. 5. Co...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Section 3 Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1Basic Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1Con...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-2 Duplicating a Configuration Duplicate the configuration of a 3095FC using these instruction. 1. File > Save Configuration to save the configuration to a specified file. 2. Establish Communications with the second unit (see...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-3 Rosemount 3095FC Download File Use this function to download a previously saved configuration to a 3095FC. Configuration files are created using the Save Configuration function. To download a previously saved configuration: 1. Select File >...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-4 CONFIGURATION Setting the Clock Immediately after connecting to a 3095FC for the first time, set the Rosemount User Interface Software Clock to ensure proper logging of history. The internal real-time clock provides time-stam...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-5 Rosemount 3095FC Configuring the System Flags Use System Flags to perform actions that affect the overall operation of the 3095FC. From the Flags screen, a configuration can be saved to Flash memory and the 3095FC can be re-initialized. NOTE C...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-6 The Clear Flash Memory procedure clears all saved restart configuration data contained in Flash memory. Only factory defaults are retained. To return the 3095FC to the original factory default settings: 1. Select Device > ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-7 Rosemount 3095FC Advanced Tab Use the following instructions to configure the Advanced System Flags tab. See Figure 3-3. 1. Select Device > Flags > Advanced Tab. 2. Enable CRC Check to perform CRC (Cyclical Redundancy Check) check on 309...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-8 3095FC Communications Ports Configuration The communication ports of the 3095FC provide a link to a PC, such as one running Rosemount User Interface Software or a host PC. The 3095FC can have up to three communication ports. ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-9 Rosemount 3095FC RBX Tab To configure the RBX, a modem must be present and appropriately configured. Use the following steps to configure the RBX tab. See Figure 3-5 on page 3-10. 1. Configure the Device > Comm Ports > General Tab (see “...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-10 Figure 3-5. Device Comm Port RBX Tab Screen 3095FC Device Configuration / Information This step establishes the Station Name, Address, Group, and other global variables that differentiate a 3095FC. Other system variables set...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-11 Rosemount 3095FC Figure 3-6. 3095FC Differentiation / Information General Screen Points Tab The Points screen allows the user to change the number of certain points that will be active. 1. Select Device > Information > Points Tab Figure...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-12 Other Information Tab This tab displays information about the firmware (Version Name, Part Number, ID, and Time Created), the boot firmware (Version Name, Part Number, and Time Created), the processor (loading), amount of RA...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-13 Rosemount 3095FC Security Configuration The 3095FC has two types of security. • Rosemount User Interface Security - Enables access to the Rosemount User Interface Software and what menu items the user can access. • 3095FC Security - Enables c...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-14 Figure 3-10. Security Access Level Screen 3095FC Security See Figure 3-11. The 3095FC Security controls access to the device Comm Ports. When enabled, login is required to use the communication ports. Each communication port...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-16 Analog Input (AI) Configuration Analog Inputs are analog signals generated by measurement devices, such as pressure and temperature transmitters, including RTD probes. The following tabs are available as part of the AI confi...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-17 Rosemount 3095FC Figure 3-12. AI General Tab Screen AI Advanced Tab The AI Advanced tab enables the user to configure features, such as filtering, A/D conversions, and clipping for the selected Analog Input. Use the following steps to configu...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-18 6. When Temp Compensation is Enabled, a temperature compensation curve is applied to the Analog Input using the board temperature of the 3095FC as a reference. Use this feature to improve the A/D conversion accuracy at tempe...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-19 Rosemount 3095FC AI Alarms Tab See Figure 3-14 on page 3-20. The AI Alarms tab sets the alarm parameters for the AI point. 1. Select Device > I/O > AI Points > Alarms 2. Set the values for the different alarms. There are six differen...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-20 Figure 3-14. AI Alarms Tab Screen Soft Points Configuration Softpoints are data storage areas that can be used by any 3095FC application. Softpoints consist of a Tag identifier, one integer value, and twenty floating values....
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-21 Rosemount 3095FC Figure 3-15. Soft Point Screen Opcode Opcode (operation code) is an instruction from a host system that informs a slave device what actions to take. Table 3-1 contains a summary and brief description of each Opcode. In some c...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-22 Certain Opcodes only send data and do not receive data from the device. For example, Opcode 8 requests the device to set the time and date. The device resets the time and date and sends back an acknowledgement in which the O...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-24 3. Enter the The Radio Power Status, which indicates the current status of the Power Control function of ON, OFF, or RBX. The Active Zone indicates which zone is currently activated for determining the Start Time, On Time, a...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-25 Rosemount 3095FC NOTE If a Report By Exception (RBX) message needs to be sent to the host PC, the radio power on DO will come on and allow the message to be sent. The hold time should be long enough to allow the 3095FC to receive a response b...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-26 General Tab The General tab sets the basic parameters for the meter. See Figure 3-19 on page 3-26 1. Select Meter > Setup. 2. Select the Point number to be configured. Enter the meter tag. Enter a unique Meter Description...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-27 Rosemount 3095FC AGA Meter Inputs Tab See Figure 3-20 on page 3-27. The Inputs tab screen defines the field inputs, including DP and SP to be used in the flow calculation. To setup the meter inputs used in the flow calculation: 1. Select Mete...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-28 Gas Quality Tab See Figure 3-21 on page 3-28 Gas Quality defines the mole percentage of twenty gas components, the Heating Value Basis, the Heating Value, and the Specific Gravity. NOTE Entering Hexane+ (C 6 +) and the mole ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-29 Rosemount 3095FC Advanced Meter Setup Tab See Figure 3-22 on page 3-30 The Meter Setup advanced tab contains a number of additional parameters that affect the flow calculation. 1. Select Meter > Setup > Advanced tab. 2. Select the FPV M...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-30 NOTE Normal recalculation periods are established in Meter Set-up screen using Integral Multiplier period or the Base Multiplier Period. Upon forcing a recalculation, the accumulations are zeroed and the flow value is logged...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-31 Rosemount 3095FC Meter Setup Alarms Tab See Figure 3-24 on page 3-32. Meter Setup Alarms allows setting the alarm limits, configure RBX Alarming, and view active alarms for the selected meter run. Alarms can be configured for the individual m...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-32 Figure 3-24. Meter Setup Alarms Tab Screen History Points Configuration The History option allows data stored in the current value database to be copied and stored for up to a month in the historical database. The historical...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-33 Rosemount 3095FC History Point 2, History Point 3, History Point 4, and History Point 6 are all setup as an Average Archive Type that employs one of the following techniques: • Flow dependent time-weighted linear averaging (default)• Flow dep...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-34 • Alarm Log: The Alarm Log contains the change in the state of any alarm signal that has been enabled for alarms. The system Alarm Log has the capacity to maintain and store up to 240 alarms in a “circular” log. The Alarm Lo...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-35 Rosemount 3095FC General History The Configure > History option allows data to be stored in the historical database. Hourly and daily values are stored for up to 35 days. The historical database can be configured to log only the values tha...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-36 • Totalize - The difference between the current value and last hour's current value is used for point values polled or received as accumulated values. The Totalization technique assumes that the value being archived is zeroe...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-38 Collect Data Select 3095FC > Collect Data to save various 3095FC data to disk files. Select the values to be saved for later generating into a report(s). This screen may only be accessed when the user is on-line with the ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-39 Rosemount 3095FC Selecting View > EFM Reports opens the initial screen. The utility program is used in conjunction with the AGA flow calculation capabilities of the 3095FC to display or print previously collected flow data. EFM Reports gen...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-40 Modbus Configuration The 3095FC has the ability to communicate using Modbus protocol. This makes it possible to integrate with Modbus devices into the same Host/Slave system. The 3095FC can act as a Slave device. The LOI, Co...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-42 Figure 3-25. Configure Modbus General Tab Screen Scale Values Tab The Scale Value tab allows the user to enter low and high floating point and integer values for converting between integer and floating point numbers. See Fig...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-43 Rosemount 3095FC 4. Enter the Float Scale # in the Low Value Float Scale and High Value Float Scale fields used when the Host is not able to process floating point numbers. In Host systems that do not accept floating point numbers, eight sets...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-44 Modbus - History Collection The Modbus protocol sends the Hourly (periodic) and Daily History. Refer to “History Access Registers Tab” on page 3-44. Each record contains a time and date stamp and all of the history archives ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-45 Rosemount 3095FC NOTE The Starting History Point and Ending History Point values must be different with the Starting History Point value being the smaller of the two. The group of history points is specified by the Modbus register value set i...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-46 Table 3-5. History, Event, and Alarm Functionality The 3095FC supports the Modbus with EFM extensions method for retrieving alarms, events, and history. When a Function code 3 request referencing defined Events/Alarms Regist...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-47 Rosemount 3095FC Table 3-6. Modbus Events and Alarms Log Content Modbus - Detailed Point / Parameter Information The Modbus Special Function Table (point type 39) returns the Event Log, Alarm Log, and the Historical Archives. The Event/Alarm ...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-48 Register numbers should be unique for a given communication port. Registers may be duplicated as long as they are assigned to separate port or located in a separate Modbus configuration table. If a register number is duplica...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-50 For example: When using Point Indexing the configuration of: Specifies four Registers (100, 101, 102, and 104) that are mapped to a group of Analog Input (AIN) values in engineering units (EU) starting at the Analog Input in...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 3-51 Rosemount 3095FC Figure 3-28. Modbus Registers Configuration Screen Modbus Conversion Conversion codes convert the data into a format that is compatible to a Modbus device. Select the Conversion field, on the Modbus Registers or Modbus Histor...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-54 CUSTOM DISPLAYS This section describes the Custom Display option. The Custom Display option allows the creation of customized “live” displays, loading a display from a disk file, and monitoring flow and I/O points. Display o...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 3-55 9. Press the Test button to display the screen as it will appear in use. Use the Update, Autoscan, Stop Scan, Edit, Save, and Close buttons at the bottom of the screen to perform the following functions: • Update - Use this ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Section 4 Calibration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1Calibrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 4-3 Rosemount 3095FC 22. When the Live Reading is stable, click Set Mid 3 to calibrate the reading. The display returns to the Meter Calibration window. 23. When the calibration for a selected point is complete, another input can be calibrated or ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 4-4 Rosemount 3095FC • Press Effect is the Zero Shift adjustment value; it is used as an offset to the calibrated EU Values to compensate for the working SP effect on a DP transmitter that was calibrated at atmospheric pressure. • Set EU Value is ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 4-5 Rosemount 3095FC Calibration Report The Calibration Report details which parameters were set during calibration. 1. Select View > Calibration Report. 2. Select the Calibration Report to be viewed. The file has the extension *.800 and is loc...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Section 5 Troubleshooting and Maintenance Backup Configuration Information . . . . . . . . . . . . . . . . . . page 5-1Communication Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-2Resettin...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC 5-2 COMMUNICATION ERRORS Several events can cause a connection failure: • If the Direct Connect communication link fails, use the Connect feature to establish a connection to the 3095FC. The Configuration Tree option allows the u...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 5-4 Rosemount 3095FC AFTER INSTALLING COMPONENTS After removing power to the 3095FC and installing components as needed, perform the following steps to start the 3095FC and reconfigure the data. NOTE Ensure all input devices, output devices, and p...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 5-5 Rosemount 3095FC REPLACING THE BATTERIES The battery pack contains three D-size lead-acid batteries providing 2.5 Amp-hours of current at 6.2 volts nominal. NOTE When installing equipment in a hazardous area, ensure that all components are app...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Appendix A Specifications and Reference Data Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC A-2 Power • Transmitter: operates on terminal voltage of 8 - 28 Vdc• Input current: 5mA nominal, 9.5 mA at 100% duty cycle (battery charging not included) • Internal battery: rechargeable, Nominal 6.2 Vdc (2.5 Amp/hr)• Maximum po...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 A-3 Rosemount 3095FC Turn-on Time Process variables will be within specifications less than 4 seconds after power is applied to transmitter. Real Time Clock • Year /month / day / hour / minute / second• Battery Packed Serial Card – EIA-232D Card S...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC A-4 Range 4 (absolute)/ Range D (gage) • 0–36.26 to 0–3,626 psi (0–2,5 to 0–250,0 bar) (100:1 rangeability is allowed) Accuracy (including Linearity, Hysteresis, Repeatability) • ±0.075% of span for spans from 1:1 to 6:1 of URL• ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 A-5 Rosemount 3095FC Process Wetted Parts Isolating Diaphragms • 316L SST or Hastelloy C -276 ® Drain/Vent Valves • 316 SST or Hastelloy C ® Flanges • Plated carbon steel, 316 SST, or Hastelloy C Wetted O-rings • Glass-Filled TFE Non-Wetted Parts ...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC A-6 Memory Specifications Programmable Memory 2 MB x 8 flash EPROM Data Memory 512 kB 5 RAM Boot Memory 128 kB flash EPROM Data Logging Archival • 60 days of 10 minutes data• 35 days of hourly data• 35 days of daily data• minimum...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 A-7 Rosemount 3095FC DIMENSIONAL DRAWINGS 3095FC Side View Front View Dimensions are in inches (millimeters) 3095FC with Solar Panel Assembly Side View Front View Dimensions are in inches (millimeters) 7.50 (191) 10.71 (272) Terminal Block 3 / 4 -...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 A-11 Rosemount 3095FC OPTIONSStandard Configuration Unless otherwise specified, the transmitter is shipped as follows: Custom Configuration (Option Code C1) If Option Code C1 is ordered, the user-specified information for the 3095F Modbus Transmit...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Appendix B Product Certifications Approved Manufacturing Locations . . . . . . . . . . . . . . . . . page B-1European Directive Information . . . . . . . . . . . . . . . . . . . . page B-1Hazardous Locations Cert...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 Rosemount 3095FC www.rosemount.com Appendix C Rosemount User Interface Software Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-1Point Type Parameter Definitions . . . . . . . . . . . . . . . . . . . pag...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-2 Point Type 0 Information Table 3 5 lists the parameters for the Configurable Opcode Point Type found in the 3095FC. The parameters for this Point Type consist of a sequence number and 44 device parameter identifications (Point ...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-4 Table C-4. Point Type – AGA Flow Parameters 16 R/O BIN 1 Alarm Code: Bit 7 – Manual ModeBit 6 – Point FailBit 5 – Not UsedBit 4 – Rate AlarmBit 3 – High High AlarmBit 2 – High AlarmBit 1 – Low Low AlarmBit 0 – Low Alarm ALARM 1...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-6 Table C-5. Point Type 8 – History Parameters 32 R/W FLP 4 C 4 H 10 – i-Butane IBUTAN 33 R/W FLP 4 C 5 H 12 – n-Pentane NPENTA 34 R/W FLP 4 C 5 H 12 – i-Pentane IPENTA 35 R/W FLP 4 C 6 H 14 – n-Hexane NHEXAN 36 R/W FLP 4 C 7 H 1...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 C-7 Rosemount 3095FC Table C-6. Point Type 10 – AGA Flow Calculation Values 22 R/O UINT 8 1 Archive Type ARCH6 23 R/O UINT 8 1 Averaging or Rate Type AVG#6 24 R/O TLP 3 Point Tag Identification TLP TAG#7 25 R/O TLP 3 History Log Point Number 7 HIST#...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-10 Table C-9. Point Type 14 – Communication Ports Parameter Number Read- Write Data Type Length Description Abbr. 0 R/W AC 10 Tag Identification TAG 1 R/W UINT 16 2 Baud Rate BAUD 2 R/W UINT 8 1 Stop Bits SBITS 3 R/W UINT 8 1 Dat...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-12 Table C-11. Point Type 17 – Soft Point Parameters 21 R/O BIN 1 ROM Installed – Memory Assignments: Bit 7 – E0000-FFFFFBit 6 – C0000-DFFFFBit 5 – A0000-BFFFFBit 4 – 80000-9FFFFBit 3 – 60000-7FFFFBit 2 – 40000-5FFFFBit 1 – 20000...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 C-13 Rosemount 3095FC Table C-12. Point Type 19 – Database Parameters NOTE Point Type 19 is used by Opcode 165 to configure history points and create events. Table C-13. Point Type 41 – Run Parameters Parameter Number Read- Write Data Type Length De...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 C-15 Rosemount 3095FC Table C-14. Point Type 42 – Extra Run Parameters Table C-15. Point Type 43 – User List Parameters Parameter Number Read- Write Data Type Length Description Abbr. 0 R/W AC 10 Point Tag Identification TAG 1 R/W FLP 4 Flow Today –...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-16 Table C-16. Point Type 44 – Power Control Parameters 16 R/W TLP 3 Data 1 17 R/W TLP 3 Data 2 18 R/W TLP 3 Data 3 19 R/W TLP 3 Data 4 20 R/W TLP 3 Data 5 21 R/W TLP 3 Data 6 22 R/W TLP 3 Data 7 23 R/W TLP 3 Data 8 24 R/W TLP 3 ...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 C-17 Rosemount 3095FC Table C-17. Point Type 45 – Meter Calibration and Sampler Table C-18. Point Type 46 – Meter Configuration Parameters Parameter Number Read- Write Data Type Length Description Abbr. 0 R/W BIN 1 Calibration Options: Bit 5 through...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 C-21 Rosemount 3095FC Table C-19. Point Type 47 – Meter Flow Values Parameter Number Read- Write Data Type Length Description Abbr. 0 R/O FLP 4 Flow rate per day (MCF or km 3 ) FLOWDY 1 R/O FLP 4 Energy rate per day (MMBTU or GJoules) ENGDAY 2 R/O F...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-22 Table C-20. Point Type 53 – Modbus Configuration Parameters 50 R/O FLP 4 Energy Accumulated (MMBTU or GJoules) ENGACC 51 R/O FLP 4 Uncorrected Today (MCF or km 3 ) UCCTDY 52 R/O FLP 4 Uncorrected Yesterday (MCF or km 3 ) UCCYD...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 C-23 Rosemount 3095FC Table C-21. Point Type 54 – Modbus Function Table Parameter Number Read- Write Data Type Length Description Abbr. 0 R/W AC 20 Point Tag Identification TAG 1 R/W UINT 16 2 Start Register #1 START1 2 R/W UINT 16 2 End Register #1...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-24 Table C-22. Point Type 55 – Modbus Special Function Table 51 R/W TLP 3 Parameter(s) PARA13 52 R/W UINT 8 1 Conversion Code CONV13 53 R/W UINT 16 2 Start Register #14 START14 54 R/W UINT 16 2 End Register #14 END14 55 R/W TLP 3...
Reference Manual 00809-0100-4832, Rev AAMarch 2004 C-25 Rosemount 3095FC Table C-23. Point Type 56 – Analog Input Calibration Parameters 37 R/W UINT 8 1 End History Point END7 38 R/W UINT 8 1 Type of History Archive TYPE7 39 R/W UINT 8 1 Conversion Code CONV7 40 R/W UINT 16 2 History Archive Registe...
Reference Manual 00809-0100-4832, Rev AA March 2004 Rosemount 3095FC C-26 Table C-24. Point Type 58 – Revision Information Table C-25. Point Type 86 – Extended History Parameters Parameter Number Read- Write Data Type Length Description Abbr. 0 R/O AC 20 Device Firmware Description DESC 1 R/O AC 10 ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Glossary A A/D - Analog to Digital AGA - American Gas Association. AI - Analog Input. AO - Analog Output. Analog - Analog data is represented by a continuous variable, such as an electrical current signal. AP - A...
Reference Manual 00809-0100-4832, Rev AA October 2004 Rosemount 3095FC Glossary-2 Discrete - Input or output that is non-continuous, typically representing two levels such as on/off. DP - Differential Pressure. DSR - Data Set Ready modem communications signal. DTR - Data Terminal Ready modem communi...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Glossary-3 Rosemount 3095FC I, J IC - Industry Canada, more recently know an Measurement Canada, which grants custody transfer approvals on certain 3095FC units. IC can also mean integrated circuit. ID - Identification IEC - Industrial Electrical ...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Glossary-5 Rosemount 3095FC ROM - Read-only memory. Typically used to store firmware. RTC - Real-time clock. RTD - Resistance Temperature Detector. RTS - Ready to Send modem communications signal. RTU - Remote Terminal Unit. RXD - Received Data co...
Reference Manual 00809-0100-4832, Rev AAOctober 2004 Rosemount 3095FC www.rosemount.com Index A Accessories . . . . . . . . . . . 1-3 , A-11 After Installing Components . . . . 5-4 Apply Power . . . . . . . . . . . . . 2-10 Approved Manufacturing Locations . B-1 Automatic Tests . . . . . . . . . . ....
Emerson Manuals
-
Emerson LD195EM8
User Manual
-
Emerson EWR20V4
User Manual
-
Emerson EWR20V4
Manual
-
Emerson SLC195EM8
User Manual
-
Emerson SLC195EM8
Manual
-
Emerson CR202EM9
User Manual
-
Emerson HD14070
User Manual
-
Emerson RLC320EM9
User Manual
-
Emerson LC320EM9
User Manual
-
Emerson LC320EM9
Manual
-
Emerson PD6922
User Manual
-
Emerson PD6922
Manual
-
Emerson EPT427D
User Manual
-
Emerson EPT427D
Manual
-
Emerson 400 VMC
User Manual
-
Emerson 400 VMC
Manual
-
Emerson CF960CK
User Manual
-
Emerson MICRO MOTION 2700
Installation Manual
-
Emerson CF787AP00
User Manual
-
Emerson CF787AP00
Manual