Page 2 - Contents; Declaration of Conformity; Functional description; Configuration mode; Application examples
2 6609-2221 Contents 1. Safety .................................................................................................................................................................................. 3 2. Approvals ..............................................................................
Page 4 - Declaration of conformity; Industrial Ethernet adapter
4 6609-2221 2.1 Declaration of Conformity Westermo Teleindustri AB Declaration of conformity Org.nr/ Säte/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016 - 42 80 00 016 – 42 80 01 52 72 79-4 5671-5550 556361-2604 Eskilstuna ...
Page 9 - Power; Contact; Direction relative ED-20
9 6609-2221 6.2 Connections ED-20 PPP ROUTER Serial Interface Power Cannel 1:RS-232 connection Cannel 2:RS-232 connection Ethernet 10Base-T connection 8 7 6 5 4 3 2 1 Ethernet 10Base-T Connection (RJ-45 connector),straight function MDI (no crossover) Contact Signal Name Direction** Description 1 TD+...
Page 12 - DIP Switch Settings; DIP-switches are accessible under the lid on top of the unit.; NOTE; The change of DIP switch settings are valid only after a power on.; Factory settings; The DIP Swiches is not used in this product, leave as it is.
12 6609-2221 6.4 DIP Switch Settings DIP-switches are accessible under the lid on top of the unit. Warning! Prevent damage to internal electronics from electrostatic discharges(ESD) by discharging your body to a grounding point (e.g. use of wriststrap), before the lid on top of the modem is removed....
Page 13 - 000 or XP‚ Or compatible OS.
13 6609-2221 6.4.1 MAC address The MAC address of the unit can be found on the product label “00 30 56 F” + last 5digits on IC2 see figure in section 6.4 Switch settings on page 12. Example: Label on IC2“SC12 RTOS 0092C2” this will give the unit MAC address “00 30 56 F0 92 C2” The MAC address can al...
Page 14 - Authentication is provided with the protocols PAP and CHAP.; * The IP address must be compliant to the attached network.
14 6609-2221 7. Functional description The ED-20 can be in either configuration mode or in application mode. Normally theED-20 is in application mode, where the serial-to-network data transfer is enabled and allconfiguration settings are readable. Change of configuration parameters are done in ED-20...
Page 15 - The connection will be open until one of following is true:; • ‘Close’ command on CH2: or via TELNET
15 6609-2221 7.1.2.2 PPP connection The PPP connection can be established over PSTN, Leased Line or private lines.ED-20 can act as a PPP Server, PPP Client or both. These functions is set on the ‘Modemsettings’ tab in ED-Tool for ED-20. See application example on page 30. Connections can be establis...
Page 16 - or
16 6609-2221 8. Configuration Before read, write or reboot can be made, Select type of connection: • Network• Serial com port must be selected from menu ‘Tools – Serial COM Port’ 8.1 Configuration by ED-Tool for ED-20 This section describes the configuration of the ED-20 with the software ED-Tool fo...
Page 18 - General
18 6609-2221 +++ DIAL IN/OUT PSTN NO NO 2 AT&F&DOSO OK 3 1 ATH OK 3 ATDS=0 CONNECT 60 0 1 RING ATA 1 600 123456 7 8.1.1.3 Modem Settings General 1 Modem Select Type of connection, PSTN or LL. Connection • Use PSTN for dial-up connections, e.g. Phone modem, GSM modem or ISDN adapter. • Use LL...
Page 20 - Login
20 6609-2221 ed20 NONE 169.254.200.100 169.254.200.101 255.255.255. 0 169.254.100.100 **** 255.255.255. 0 1 2 3 4 5 678 8.1.1.4 Network Settings Login 1 Authentication Select if authentication shall be used or not. 2 Username Set the login username.This is also used for Telnet sessions (Network conf...
Page 22 - IP Address
22 6609-2221 . . . 1 2 3 4 5 8.1.1.6 Firewall Settings Firewall Mode 1 Off / Pass / Block Disables or enables the Firewall mode and selects if the firewall shall work in Block or Pass mode. See 8.2.5 Firewall Settings 2 IP Address Set the source and destination IP addresses that shall be allowedto p...
Page 23 - Configurable parameters; Communication
23 6609-2221 8.2 Configurable parameters 8.2.1 Serial interface Communication Data Rate The data rate can be set from 1 200 bit/s to 115.2 kbit/s. Allowed values: 1 200, 2 400, 4 800, 7 200, 9 600, 14 400, 16 000, 19 200, 38 400, 56 000, 57 600 and 115 200 bit/s. Default: 57 600 bit/s. Flow Control ...
Page 27 - Answer; Command that will answer the incoming call.; Timeout; Username; Password
27 6609-2221 Answer Command that will answer the incoming call. Default: ATA Timeout Define the time in seconds, For how long time the ED-20 will accept incoming calls frompower-up. Normally not used, leave as is. Allowed values: 0-9999Default: 0 8.2.3 Network Settings Login The login username and p...
Page 30 - Example of application with IP address settings.
30 6609-2221 9. Application examples Example of application with IP address settings. Remote connection – LAN (Dial In) LAN – LAN (Leased Line) LAN – LAN (PSTN, GSM) 169.254.200.100 169.254.200.101 255.255.255. 0 169.254.100.100 255.255.255. 0 +++ DIAL IN PSTN NO NO PSTN LAN PLC PLC ED-20 TD-33 Remo...
Page 31 - LAN; PSTN
31 6609-2221 LAN – LAN (PSTN, Brouter, Firewall) 169.254.100.101 ATDnnnnnn 169.254.200.100 169.254.200.101 255.255.255. 0 169.254.100.100 255.255.255. 0 PLC TD-34 169.254.200.100 169.254.200.101 255.255.255. 0 179.254.100.100 255.255.255. 0 LAN PLC PLC ED-20 TD-34 ED-20 PPP ROUTER Serial Inter face ...