Page 2 - SAFETY INFORMATION; WARNINGS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; Natural and propane/LP gases are; WARNING: Any change to this heater or its; Do not install 10,000 Btu units in a bathroom.; TABLE OF CONTENTS
110720-01A 2 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully andcompletely before trying to assemble, operate, or ...
Page 3 - UNPACKING; Continued; PRODUCT IDENTIFICATION; SAFETY DEVICE; LOCAL CODES; Blue Flame Heater; Infrared Heater
110720-01A 3 3 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m SAFETY INFORMATION UNPACKING PRODUCT IDENTIFICATION PRODUCT FEATURES LOCAL CODES 4. If you smell gas• Shut off gas supply• Do...
Page 4 - PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
110720-01A 4 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m AIR FOR COMBUSTION ANDVENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight constructi...
Page 5 - VENTILATION AIR; Ventilation Air From Inside Building; Figure 2 - Ventilation Air from Inside Building; Ventilation Air From Outdoors; Do not provide openings for inlet or outlet air into
110720-01A 5 5 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m WARNING: If the area in which the heater may be operated is smaller than that defined as an uncon-fined space or if the build...
Page 6 - INSTALLATION; CHECK GAS TYPE
110720-01A 6 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 36" 3" CEILING Minimum Minimum To TOf Carpeting, 6" Blueflame 8" Plaque MinimumFromSides OfHeater RightSide Lef...
Page 7 - Marking Screw Locations; WARNING: Maintain minimum clearances shown; Installing Two Mounting Screws; Wall anchors and mounting screws are in hardware package.; Placing Heater On Mounting Screws
110720-01A 7 7 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m INSTALLATION Installing Heater To Wall INSTALLATION Continued Figure 5 - Mounting Screw Locations INSTALLING HEATER TO WALL M...
Page 8 - Installing Bottom Mounting Screw; Mark screw location on wall.; Figure 11 - Installing Bottom Mounting Screw; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; For natural gas, check gas line pressure before; Install an equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant
110720-01A 8 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m INSTALLATION Continued Installing Bottom Mounting Screw 1. Locate bottom mounting hole. This hole is near bottom on backpanel o...
Page 9 - CHECKING GAS CONNECTIONS; WARNING: Test all gas piping and connections; Figure 14 - Equipment Shutoff Valve; Figure 13 - Gas Connection; Hold pressure regulator with wrench when con-; Connecting; Pressure Testing Gas Supply Piping System; Correct all leaks at once.
110720-01A 9 9 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m ON POSITIO OF POSI CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servic...
Page 10 - Figure 16 - Checking Gas Joints for Propane/LP Gas; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; OPERATING HEATER; FOR YOUR SAFETY READ; WARNING: If you do not follow these instructions; LIGHTING INSTRUCTIONS; MANUAL CONTROL BLUE FLAME
110720-01A 10 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m INSTALLATION Continued Propane/LPSupply Tank ControlValve Location Figure 16 - Checking Gas Joints for Propane/LP Gas Figure 1...
Page 11 - Shutting Off Heater; Shutting Off Burner Only (pilot stays lit); MANUAL CONTROL INFRARED MODELS; CAUTION: Do not try to adjust heating levels by; Figure 17 - Control Knob In The OFF Position; OPERATING HEATER (Manual Control Blue Flame Models); OPERATING HEATER (Manual Control Infrared Models)
110720-01A 11 11 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m OFF HIGH PILOT LOW IGNITOR OPERATING HEATER Continued TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figure 10, pa...
Page 12 - WARNING: When running heater, set control; TO TURN OFF GAS
110720-01A 12 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m OFF PILOT IGNITOR LOW HIGH 1. STOP! Read the safety information page 11, column 2. 2. Make sure equipment shutoff valve is ful...
Page 14 - to the OFF position.; Turn control knob clockwise; to the PILOT position.; TO TURN OFF GAS TO APPLIANCE; The thermostat sensing bulb measures the temperature of; INSPECTING BURNER; PILOT FLAME PATTERN; WARNING: If yellow tipping occurs, your heater; Figure 26 - Correct Burner Flame Pattern
110720-01A 14 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m GRH/OV 007 GOOD PILOT/LP GRH/OV 008 BAD PILOT/LP 1/2 GLASS HEIGHT 1/2 GLASS HEIGHT Shutting Off Heater 1. Turn control knob cl...
Page 15 - ODS/PILOT AND BURNER ORIFICE; Air Passageways; CLEANING AND MAINTENANCE
110720-01A 15 15 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m CLEANING ANDMAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner...
Page 16 - TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
110720-01A 16 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m TROUBLESHOOTING TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Onlya qualified service person shoulds...
Page 17 - OBSERVED PROBLEM; nance, page 15) or replace burner orifice
110720-01A 17 17 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustio...
Page 18 - IMPORTANT; REMEDY
110720-01A 18 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch a...
Page 19 - SPECIFICATIONS
110720-01A 19 19 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m VP600BA VP5D VP10A VP1000BTA Btu (Variable) 4,400/6,000 5,500 5,500/10,000 5,000/10,000 Type Gas Propane/LP Only Propane/LP...
Page 20 - ILLUSTRATED PARTS BREAKDOWN; PILOT
110720-01A 20 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m VN600BAVP600BA ILLUSTRATED PARTSBREAKDOWN ILLUSTRATED PARTS BREAKDOWN VN600BA, VP600BA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 ...
Page 21 - PARTS LIST
110720-01A 21 21 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m PARTS LIST This list contains replaceable parts used in your heater. Whenordering parts, follow the instructions listed und...
Page 23 - KEY
110720-01A 23 23 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m PARTS LIST This list contains replaceable parts used in your heater. Whenordering parts, follow the instructions listed und...
Page 28 - TECHNICAL SERVICE; PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low
110720-01A 28 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m EQUIPMENT SHUTOFFVALVE - GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. TECHNICAL SERVICE You may have ...
Page 29 - OWNER'S REGISTRATION FORM
110720-01A 29 29 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 1. Where will the product be used? ❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ ...
Page 30 - Postage; T APE
110720-01A 30 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 TM Postage Required T APE TAPE
Page 31 - PARTS CENTRALS
110720-01A 31 31 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m Baltimore Electric 1348 Dixwell AvenueHamden, CT 06514-03221-800-397-7553203-248-7553Parts Department Portable Heater Parts...
Page 32 - LIMITED WARRANTY; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
110720-01A 32 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m LIMITED WARRANTY DESA INTERNATIONAL VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from...