Page 2 - PROPANE/LP GAS HEATER; Carbon Monoxide Poisoning:; WARNINGS; WARNING: Any change to this
2 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® SAFETYINFORMATION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble theflu, with headaches, dizziness, and/or nau-sea. If you have these signs, the heater maynot be working properly. Get fresh air atonce! Have heater s...
Page 3 - OWNER’S MANUAL; SAFETY PILOT; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; Remove heater from carton.
3 104266 OWNER’S MANUAL PRODUCTIDENTIFICATION PRODUCTFEATURES SAFETY PILOT This heater has a pilot with an OxygenDepletion Sensing (ODS) safety shutoff sys-tem. The ODS/pilot is a required feature forvent-free room heaters. The ODS/pilot shutsoff the heater if there is not enough fresh air. PIEZO IG...
Page 4 - Unusually Tight Construction
4 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® AIR FORCOMBUSTION ANDVENTILATION PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code. NFPA 54/ANS Z223.1, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowing v...
Page 5 - DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space; Continued
5 104266 OWNER’S MANUAL WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one ofthe methods described in the National Fuel Gas Code, AN...
Page 6 - Figure 2 - Ventilation Air from Inside Building; Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for
6 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 WARNING: Rework work- sheet, adding th...
Page 7 - Figure 5 - Mounting Screw Locations; Marking Screw Locations; WARNING: Maintain minimum; INSTALLATION; CHECK GAS TYPE; WARNING: Never install the
7 104266 OWNER’S MANUAL Figure 5 - Mounting Screw Locations Mounting Screw Locations 8 7 / 8 " Minimum To Maintain 6" ClearanceFrom Wall 7 3 / 4 " 20 1 / 4 " Minimum To Maintain 3" Clearance From Floor FLOOR JOINING WALL INSTALLING HEATER TOWALL Marking Screw Locations 1. Determi...
Page 8 - Installing Two Mounting Screws; Wall anchors and mounting screws; Attaching To Wall Stud Method; IMPORTANT; Figure 8 - Tightening Anchors; Removing Front Panel Of Heater
8 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack-age is provided with heater. Attaching To Wall Stud Method For attaching mounting screw to wall stud 1. Drill hole at marked locatio...
Page 9 - Figure 13 - Gas Connection; CAUTION: Never connect; Hold pressure regulator
9 104266 OWNER’S MANUAL Figure 13 - Gas Connection * An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is anacceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory, page 18. Tee Jo...
Page 10 - WARNING: Never use an open; Correct all leaks at once.; Figure 14 - Equipment Shutoff Valve; Figure 15 - Checking Gas Joints; FOR YOUR SAFETY
10 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® CHECKING GASCONNECTIONS Pressure Testing Gas SupplyPiping System Test Pressures In Excess Of 1/2 PSIG(3.5 kPa) 1. Disconnect appliance with its appliancemain gas valve (control valve) and equip-ment shutoff valve from gas supply pip-ing system....
Page 11 - CAUTION: Do not try to adjust; Shutting Off Heater
11 104266 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figure 10,page 8). 2. Follow steps 1 through 5 under Light-ing Instructions. 3. With control knob pressed in, strikematch. Hold match to pilot until pi-lot lights. 4. Keep control knob pressed in for 30seconds after lig...
Page 12 - PILOT FLAME PATTERN; Figure 18 - Correct Pilot Flame Pattern; BURNER FLAME PATTERN; WARNING: If yellow tipping; Figure 20 - Correct Burner Flame Pattern; CABINET; Air Passageways; Figure 22 - Pilot Inlet Air Hole
12 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® GRH/OV 008 BAD PILOT/LP INSPECTINGBURNER Check pilot flame pattern and burner flamepattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat-tern. Figure 19 shows an incorrect pilotflame pattern. The incorrect pilot flame isn...
Page 13 - TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
13 104266 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing.Only a qualified service per-son should service and repairheater. CAUTION: Never use a wire, needle, or similar object to cleanODS/pilot. This can damage ODS/pilot unit. POSSIBLE CAUSE 1. Ignitor electrod...
Page 14 - REMEDY; nance, page 12) or replace burner orifice
14 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® TROUBLESHOOTING Continued REMEDY 1. Clean burner orifice (see Cleaning and Maintenance, page 12) or replace burnerorifice 2. Replace burner orifice3. Contact local propane/LP gas company 1. Contact local propane/LP gas company2. Clean burner or...
Page 15 - OBSERVED PROBLEM
15 104266 OWNER’S MANUAL WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you can...
Page 17 - PARTS LIST; KEY
17 104266 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructionslisted under Replacement Parts on page 18 of this manual. PARTS LIST KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-03 Front Panel Assembl...
Page 18 - SPECIFICATIONS; When Gas Pressure Is Too Low; SERVICE HINTS; PARTS UNDER WARRANTY; ACCESSORY
18 104266 PROPANE/LP GAS HEATER BLUE FLAME 10,000 BTU ® SPECIFICATIONS VP1000BTA Btu(Variable) 5,000/10,000 Type Gas Propane/LP Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water) 14" Max. / 11" Min. Heater Dimensions (Includes knobs and grill) 21....
Page 19 - NOTES
19 104266 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________________________________________...
Page 20 - KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; INTERNATIONAL; LIMITED WARRANTY; NOT A UPC
KEEP THIS WARRANTY WARRANTY INFORMATION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.We make no other warranty, expressed or im...