Page 2 - BLUE FLAME 10,000 BTU NATURAL GAS HEATER; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
2 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble theflu, with headaches, dizziness, and/or nau-sea. If you have these signs, the heater maynot be working properly. Get fresh air atonce! Have heater serviced. Some peoplea...
Page 3 - OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; Remove heater from carton.; UNPACKING; SAFETY PILOT
3 104265 OWNER’S MANUAL PRODUCTIDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223.1 also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Br...
Page 4 - Unusually Tight Construction
4 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code. NFPA 54/ANS Z223.1, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowing ventilation classifications: 1. Unusu...
Page 5 - DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space; Continued
5 104265 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless p...
Page 6 - Figure 2 - Ventilation Air from Inside Building; Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for
6 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 AIR FORCOMBUSTION ANDVENTILATION Continue...
Page 7 - Figure 5 - Mounting Screw Locations; Marking Screw Locations; WARNING: Maintain minimum; INSTALLATION; CHECK GAS TYPE; CAUTION: If you install the
7 104265 OWNER’S MANUAL Figure 5 - Mounting Screw Locations Mounting Screw Locations 8 7 / 8 " Minimum To Maintain 6" ClearanceFrom Wall 7 3 / 4 " 20 1 / 4 " Minimum To Maintain 3" Clearance From Floor FLOOR JOINING WALL INSTALLING HEATER TOWALL Marking Screw Locations 1. Determi...
Page 8 - Installing Two Mounting Screws; Attaching To Wall Stud Method; Removing Front Panel Of Heater; Do not replace front panel at this
8 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack-age is provided with heater. Attaching To Wall Stud Method For attaching mounting screw to wall stud 1. Drill hole at marked location u...
Page 9 - Figure 12 - Gas Connection; Check gas line pressure be-; WARNING: Never connect
9 104265 OWNER’S MANUAL * A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptablealternative to test gauge connection. Purchase the optional CSA/AGA design-certifiedequipment shutoff valve from your dealer. See Accessory, page 18. Tee Joint ReducerBushing to1/8"...
Page 10 - WARNING: Never use an open; Correct all leaks at once.; Figure 13 - Equipment Shutoff Valve; FOR YOUR SAFETY
10 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® CHECKING GASCONNECTIONS WARNING: Test all gas pip- ing and connections for leaksafter installing or servicing. Cor-rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply amixture of liquid soap and waterto all joints. ...
Page 11 - CAUTION: Do not try to adjust; Shutting Off Heater
11 104265 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figure 10,page 8). 2. Follow steps 1 through 5 under Light-ing Instructions. 3. With control knob pressed in, strikematch. Hold match to pilot until pi-lot lights. 4. Keep control knob pressed in for 30seconds after lig...
Page 12 - PILOT FLAME PATTERN; Figure 17 - Correct Pilot Flame Pattern; BURNER FLAME PATTERN; WARNING: If yellow tipping; Figure 19 - Correct Burner Flame Pattern; CABINET; Air Passageways; Figure 21 - Pilot Inlet Air Hole
12 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® INSPECTINGBURNER Check pilot flame pattern and burner flamepattern often. PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pat-tern. Figure 18 shows an incorrect pilotflame pattern. The incorrect pilot flame isnot touching the thermocoupl...
Page 13 - TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
13 104265 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Onlya qualified service person shouldservice and repair heater. POSSIBLE CAUSE 1. Ignitor electrode positioned wrong2. Ignitor electrode broken3. Ignitor electrode not connected to igni- tor cable 4. Ign...
Page 14 - OBSERVED PROBLEM; nance, page 12) or replace burner orifice
14 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Heater produ...
Page 15 - IMPORTANT
15 104265 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s ...
Page 17 - PARTS LIST; KEY
17 104265 OWNER’S MANUAL PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructionslisted under Replacement Parts on page 18 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-03 Front Panel Assembl...
Page 18 - SPECIFICATIONS; When Gas Pressure Is Too Low; SERVICE HINTS; PARTS UNDER WARRANTY; ACCESSORY
18 104265 BLUE FLAME 10,000 BTU NATURAL GAS HEATER ® You may have further questions about in-stallation, operation, or troubleshooting. Ifso, contact DESA International’s TechnicalService Department at 1-800-323-5190. You can also visit DESA International’st e c h n i c a l s e r v i c e w e b s i t...
Page 19 - NOTES
19 104265 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________________________________________...
Page 20 - KEEP THIS WARRANTY; Model; WARRANTY INFORMATION; INTERNATIONAL; LIMITED WARRANTY; NOT A UPC
KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard writtenwarranty. We make no other warranty, expr...