2 104131 NATURAL GAS CONSTRUCTION HEATER TC100RNG THEORY OFOPERATION The Fuel System: The gas supply at- taches to the heater by a minimum 3/4 inchi.d. hose or flexible connector. User mustsupply hose or flexible connector. The lengthshould be no more than 10 feet long. Thenatural gas moves through ...
3 104131 OWNER’S MANUAL PRODUCTIDENTIFICATION NATURAL GASSUPPLY The user must furnish the natural gas supplyand the connections to the heater. Regulate the natural gas supply down froma minimum 6 inches water column to amaximum of 1/2 psi. The natural gas supplycapacity should be able to supply a mi...
4 104131 NATURAL GAS CONSTRUCTION HEATER TC100RNG TO STOP HEATER 1. Close valve on gas supply. 2. Turn control valve knob 1/4 turn toright to PILOT position. Slightly pushin knob and turn 1/4 turn to right to OFFposition (see Figure 6). STORAGE 1. Place plastic cover cap over brass fit-ting on inlet...