Page 2 - PORTABLE FORCED AIR HEATER; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
2 106068 PORTABLE FORCED AIR HEATER 200,000 BTU/HR • Use only kerosene or No. 1 fuel oil toavoid risk of fire or explosion. Never usegasoline, naphtha, paint thinners, alco-hol, or other highly flammable fuels. • Fuelinga) Personnel involved with fueling shall be qualified and thoroughly familiarwit...
Page 3 - OWNER’S MANUAL; UNPACKING
3 106068 OWNER’S MANUAL 1. Remove all packing items applied toheater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. Ifheater is damaged, promptly informdealer where you bought heater. PRODUCTIDENTIFICATION UNPACKING Figure 1 - 200,000 Btu/Hr Model LowerShell Hot A...
Page 4 - Use a KEROSENE ONLY; TOOLS NEEDED; When installing wheels,; ASSEMBLY; FUELS
4 106068 PORTABLE FORCED AIR HEATER 200,000 BTU/HR WARNING: Use only kero- sene or No. 1 fuel oil to avoidrisk of fire or explosion. Neveruse gasoline, naphtha, paintthinners, alcohol, or other highlyflammable fuels. Do not use heavy fuels such as No. 2 fuel oilor No. 2 Diesel. Using heavy fuels wil...
Page 5 - The air pump forces; OPERATION; TO STOP HEATER
5 106068 OWNER’S MANUAL THEORY OFOPERATION The Fuel System: The air pump forces air through the air line. The air is thenpushed through the burner head nozzle. Thisair causes fuel to lift from the tank. A finemist of fuel is sprayed into the combustionchamber. The Air System: The motor turns the fan...
Page 6 - Item; WARNING: Never service heater
6 106068 PORTABLE FORCED AIR HEATER 200,000 BTU/HR Item How Often How To Fuel tank Flush every 150-200 hours See Storing, Transporting, or of operation or as needed Shipping Air output and Replace every 500 hours of See Air Output, Air Intake, lint filters operation or once a year and Lint Filters, ...
Page 7 - WARNING: Never service heater while it is plugged in, operat-; TROUBLESHOOTING; OBSERVED FAULT
7 106068 OWNER’S MANUAL WARNING: Never service heater while it is plugged in, operat- ing, or hot. Severe burns and electrical shock can occur. TROUBLESHOOTING OBSERVED FAULT Heater ignites, but flame-out control shutsoff heater after a short period of time Heater will not ignite, but motor runs for...
Page 8 - UPPER SHELL REMOVAL; WARNING: Never service
8 106068 PORTABLE FORCED AIR HEATER 200,000 BTU/HR SERVICEPROCEDURES UPPER SHELL REMOVAL 1. Remove screws along each side ofheater using 5/16" nut-driver. Thesescrews attach upper and lower shellstogether. 2. Lift upper shell off. 3. Remove fan guard. FAN IMPORTANT: Remove fan from motor shaft b...
Page 9 - FUEL FILTER; FUEL VALVE; WARNING: High Voltage
9 106068 OWNER’S MANUAL PUMP PRESSUREADJUSTMENT 1. Remove pressure gauge plug from filterend cover. 2. Install accessory pressure gauge (partnumber HA1180). 3. Start heater (see Operation, page 5).Allow motor to reach full speed. 4. Adjust pressure to 6.0 PSI. Turn reliefvalve to right to increase p...
Page 10 - NOZZLE
10 106068 PORTABLE FORCED AIR HEATER 200,000 BTU/HR 9. Blow compressed air through face ofnozzle. This will free any dirt in nozzle area. 10. Inspect nozzle seal for damage. 11. Replace nozzle into burner head and tighten firmly (80-110 inch-pounds). 12. Attach burner head to combustion chamber. 13....
Page 11 - PUMP ROTOR
11 106068 OWNER’S MANUAL PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using5/16" nut-driver. 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16"nut-driver. 5. Remove pump plate. 6. Remove roto...
Page 12 - Motor and Pump Assembly
12 106068 PORTABLE FORCED AIR HEATER 200,000 BTU/HR ILLUSTRATEDPARTSBREAKDOWN REM200T Motor and Pump Assembly 7-1 7-8 Burner Head Assembly 7-7 7-3 7-4 7-5 7-6 10-16 10-17 10-15 10-18 10-14 10-13 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 ...
Page 13 - PARTS LIST
13 106068 OWNER’S MANUAL PARTS LIST REM200T 200,000 Btu/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide thecorrect model and serial numbers (from the model plate), then the part number and description of thedesired part. KEY PART NO. NUMBER DESCRI...
Page 14 - WHEELS AND HANDLE PARTS LIST; PARTS AVAILABLE - NOT SHOWN; SPECIFICATIONS
14 106068 PORTABLE FORCED AIR HEATER 200,000 BTU/HR 1 2 3 4 WHEELS AND HANDLE PARTS LIST KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 HA2204 Handles 2 2 M12345-33 Screw, #10-24 x 1 3 / 4 " 8 3 M12831-3 Wheel Support Frame 1 4 NTC-3C Hex Nut, #10-24 8 5 097896-04 Wheel 2 6 M28526 Cap Nut 2 7 M1680...
Page 15 - WIRING DIAGRAM; PARTS UNDER WARRANTY; ACCESSORIES
15 106068 OWNER’S MANUAL White Black Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow Thermostat WIRING DIAGRAM Note: Use only or...
Page 16 - WARRANTY AND REPAIR SERVICE; WARRANTY SERVICE; LIMITED WARRANTY; KEEP THIS WARRANTY; INTERNATIONAL; NOT A UPC
WARRANTY AND REPAIR SERVICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater.The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International...