Page 2 - SAFETY INFORMATION
www.desatech.com 115423-01A 2 SAFETY INFORMATION IMPORTANT: Read this manual carefully and completely before trying to assemble, operate or service this product. When using electrical products, the following basic safety precautions should always be followed to reduce the risk of fire, electric shock...
Page 3 - Continued; Troubleshooting; This product contains and/or; INSTRUCTIONS; GROUND FAULT INTERRUPTER; Figure 2 - Plug Adapter; Figure 1 - GFCI Options
www.desatech.com 115423-01A 3 SAFETY INFORMATION Continued 29. Use only in accordance with the local ordi- nances and codes. 30. This product is not to be used as the sole support for an umbrella. Umbrella must be supported by a table. 31. Do not use or install umbrella into product at temperatures ...
Page 4 - ARRANGEMENT OF MANUAL; TECHNICAL SERVICE DEPARTMENT; INSTRUMENT; Air Intakes
www.desatech.com 115423-01A 4 PRODUCT IDENTIFICATION GENERAL INFORMATION ARRANGEMENT OF MANUAL This manual contains information and service procedures to assist the service technician in understanding and correcting problems on DESA Heating Products Umbrella Stand and Electric Foot Warmer. The first ...
Page 5 - stand the warnings in the; Safety; They are needed to safely oper-; CLEANING; DURING SEASON CARE; WIRING DIAGRAM; SAFETY REQUIREMENTS
www.desatech.com 115423-01A 5 INSTALLATION 1. Locate product under outdoor patio table on hard, level, dry surface. Post of tip over switch must be on solid surface for product to work. Listen for the “click”. See Figure 3 for switch location. 2. Slowly lower umbrella pole into product. Do not drop ...
Page 6 - Figure 5 - Resetting Thermal Limit Switch; Push Rod; INSPECTION; Figure 4 - System Operation; TROUBLESHOOTING; CAUTION: Risk of electric; If your product fails to operate:; Thermal Limit Switch; THERMAL LIMIT SWITCH; Resetting Thermal Limit Switch; Air Intake Openings
www.desatech.com 115423-01A 6 CAUTIONS 1. Before servicing, disconnect the heater from the electrical power source by removing the electrical plug from the wall receptacle. Note: When certain tests require electrical power to be applied, connect electrical power only for the time necessary to comple...
Page 7 - Figure 6 - Testing Motor; OBSERVED FAULT; Open Tubular Heating Element; Figure 7 - Testing Heating Element
www.desatech.com 115423-01A 7 TROUBLESHOOTING Continued 7. Replace removed plug in hole. Perform a trial operation. 8. If repeated resetting of the thermal limit switch is required, have the product serviced by an authorized service center. OBSERVED FAULT Tubular heating element heats up but no rush...
Page 8 - REASSEMBLY POINTS
www.desatech.com 115423-01A 8 REASSEMBLY POINTS Because this is an outdoor product where the control of water is important, the following steps for assembly must be followed.1. The closed cell foam gasket must seal the hex shaped pan to the inside of the plastic housing (see Figure 8). The seal is t...
Page 9 - Figure 14 - Heating Element and Bracket
www.desatech.com 115423-01A 9 7. Tubular heating element must be flush against bracket (see Figure 14). This centers the ele- ment to the center hole in metal pan. 8. Fan must be located with set screw at back of and on flat of shaft (see Figure 15). 9. Heater is equipped with heat reflective tape. If ...
Page 10 - ILLUSTRATED PARTS BREAKDOWN
www.desatech.com 115423-01A 10 ILLUSTRATED PARTS BREAKDOWN 19 1 7 28 14 16 9 8 2 17 18 27 26 15 Requires Loctite Thread Locker Blue 6 3 22 23 20 13 11 10 21 2 12 24 25 SteelNut BrassWasher Rubber Seal Bottom View 5 4
Page 11 - PARTS LIST; NUMBER
www.desatech.com 115423-01A 11 PARTS LIST This list contains replaceable parts used in your product. When ordering parts, be sure to provide the correct model and serial numbers (from the identification decal), then the part number and description of the desired part. KEY PARTNO. NUMBER DESCRIPTION Q...
Page 12 - NOT A UPC
115423 01 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004www.desatech.com 115423-01Rev. A10/04 NOT A UPC