Page 2 - SAFETY INFORMATION; WARNINGS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; Natural and propane/LP gases are; WARNING: Any change to this heater or its; Do not install 10,000 Btu units in a bathroom.; TABLE OF CONTENTS
107902-01D 2 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully andcompletely before trying to assemble, operate, or ...
Page 3 - UNPACKING; Continued; PRODUCT IDENTIFICATION; SAFETY DEVICE; LOCAL CODES; Blue Flame Heater; Infrared Heater
107902-01D 3 3 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m SAFETY INFORMATION UNPACKING PRODUCT IDENTIFICATION PRODUCT FEATURES LOCAL CODES 4. If you smell gas• Shut off gas supply• Do...
Page 4 - PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; ings gasketed or sealed; Confined and Unconfined Space; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
107902-01D 4 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m AIR FOR COMBUSTION ANDVENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight constructi...
Page 5 - VENTILATION AIR; Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 2 - Ventilation Air from Inside Building
107902-01D 5 5 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m WARNING: If the area in which the heater may be operated is smaller than that defined as an uncon-fined space or if the build...
Page 6 - INSTALLATION; CHECK GAS TYPE; Figure 4 - Mounting Clearances As Viewed From Front of Heater
107902-01D 6 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 36" 3" CEILING Minimum Minimum To TOf Carpeting, 6" Blueflame 8" Plaque MinimumFromSides OfHeater RightSide Lef...
Page 7 - INSTALLING HEATER TO WALL; Marking Screw Locations; Determine where you will locate heater.; WARNING: Maintain minimum clearances shown; Installing Two Mounting Screws; Wall anchors and mounting screws are in hardware package.; Placing Heater On Mounting Screws; Locate two keyhole slots on back panel of heater (see Figure 9).
107902-01D 7 7 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m INSTALLATION Installation Items Locating Heater Installing Heater To Wall INSTALLATION Continued Figure 5 - Mounting Screw Lo...
Page 8 - Figure 11 - Installing Bottom Mounting Screw; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; Removing Front Panel Of Heater; Figure 10 - Removing Front Panel Of Heater; Installing Bottom Mounting Screw; Do not replace front panel at this time. Replace front
107902-01D 8 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m Figure 11 - Installing Bottom Mounting Screw CONNECTING TO GAS SUPPLY WARNING: This appliance requires a 3/8" NPT (National...
Page 9 - Figure 13 - Gas Connection; Hold pressure regulator with wrench when con-; CHECKING GAS CONNECTIONS; WARNING: Test all gas piping and connections; Pressure Testing Gas Supply Piping System; Correct all leaks at once.; WARNING: Use pipe joint sealant that is resistant
107902-01D 9 9 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m INSTALLATION Continued INSTALLATION Connecting To Gas Supply (Cont.) Checking Gas Connections Figure 13 - Gas Connection * A ...
Page 10 - Figure 14 - Equipment Shutoff Valve; Figure 16 - Checking Gas Joints for Propane/LP Gas; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.
107902-01D 10 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m ON POSITIO OF POSI Figure 14 - Equipment Shutoff Valve EquipmentShutoff Valve Open Closed Propane/LPSupply Tank ControlValve L...
Page 11 - OPERATING HEATER; FOR YOUR SAFETY READ; WARNING: If you do not follow these instructions; LIGHTING; MANUAL CONTROL BLUE FLAME; OPERATING HEATER (Manual Control Blue Flame Models); CAUTION: Do not try to adjust heating levels by; Figure 17 - Control Knob In The OFF Position
107902-01D 11 11 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or e...
Page 12 - Shutting Off Heater; Shutting Off Burner Only (pilot stays lit); MANUAL CONTROL INFRARED MODELS
107902-01D 12 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m OFF PILOT IGNITOR LOW HIGH OPERATING HEATER Continued TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figure 10, page ...
Page 13 - Control; OPERATING HEATER (Manual Control Infrared Models); THERMOSTAT CONTROL BLUE FLAME
107902-01D 13 13 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m LOW OFF PILOT HIGH OFF PILOT OFF WARNING: When running heater, set control knob at LOW or HIGH locked positions. Never set ...
Page 15 - INSPECTING BURNER; PILOT FLAME PATTERN; WARNING: If yellow tipping occurs, your heater; Figure 26 - Correct Burner Flame Pattern
107902-01D 15 15 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m GRH/OV 007 GOOD PILOT/LP GRH/OV 008 BAD PILOT/LP 1/2 GLASS HEIGHT 1/2 GLASS HEIGHT INSPECTING BURNER Check pilot flame patt...
Page 16 - ODS/PILOT AND BURNER ORIFICE; • Use a vacuum cleaner, pressurized air, or small, soft bristled; CLEANING BURNER PILOT AIR INLET HOLE; Blow air through the ports/slots and holes in the burner.; CABINET; Air Passageways; • Use a vacuum cleaner or pressurized air to clean.; Exterior; • Use a soft cloth dampened with a mild soap and water mixture.; Figure 30 - Pilot Inlet Air Hole; CLEANING AND MAINTENANCE
107902-01D 16 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m CLEANING ANDMAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, a...
Page 17 - WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in; TROUBLESHOOTING
107902-01D 17 17 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Onlya qualified service person shouldservice and re...
Page 18 - OBSERVED PROBLEM; nance, page 16) or replace burner orifice
107902-01D 18 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion B...
Page 19 - IMPORTANT; REMEDY
107902-01D 19 19 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touc...
Page 20 - ILLUSTRATED PARTS BREAKDOWN; PILOT
107902-01D 20 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m GWP6GWN6GWP10GWN10 ILLUSTRATED PARTSBREAKDOWN 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16 ILLUS...
Page 21 - PARTS LIST; KEY
107902-01D 21 21 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m PARTS LIST This list contains replaceable parts used in your heater. Whenordering parts, follow the instructions listed und...
Page 26 - SPECIFICATIONS
107902-01D 26 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m GWP6 GWP10 GWRP10 GWP10T Btu (Variable) 4,400/6,000 5,000/10,000 5,500/10,000 5,000/10,000 Type Gas Propane/LP Only Propane/LP...
Page 27 - EQUIPMENT SHUTOFF VALVE - GA5010; TECHNICAL SERVICE; PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low; REPLACEMENTS PARTS
107902-01D 27 27 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m EQUIPMENT SHUTOFF VALVE - GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. TECHNICAL SERVICE You may h...
Page 28 - PARTS CENTRALS
107902-01D 28 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m Baltimore Electric 1348 Dixwell AvenueHamden, CT 06514-03221-800-397-7553203-248-7553Parts Department Portable Heater Parts 34...
Page 29 - OWNER'S REGISTRATION FORM
107902-01D 29 29 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 1. Where will the product be used? ❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ ...
Page 30 - Postage; T APE
107902-01D 30 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 Postage Required TM T APE TAPE
Page 31 - NOTES
107902-01D 31 31 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m NOTES _______________________________________________________________________________________________ _____________________...
Page 32 - LIMITED WARRANTY; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
107902-01D 32 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m LIMITED WARRANTY DESA INTERNATIONAL VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from...