Page 2 - SAFETY INFORMATION; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its; TABLE OF CONTENTS
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoni...
Page 3 - Continued; PRODUCT IDENTIFICATION
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 1. This appliance is only for use with the type of gas indicated onthe rating plate. This appliance is not convertible for use wi...
Page 4 - LOCAL CODES; Where listed vented decorative logs are required, thermostat; PRODUCT FEATURES; OPERATION; UNPACKING; CAUTION: Do not remove the data plates from the; PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; WARNING: This heater shall not be installed in a
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODESUNPACKINGPRODUCT FEATURESAIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation LOCAL CODES Install and use h...
Page 5 - AIR FOR COMBUSTION AND VENTILATION; Confined Space and Unconfined Space; per kw) of the aggregate input rating
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 5 5 AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation (Cont.) Determining Fresh-Air Flow For Heater Location Unusuall...
Page 6 - Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors; INSTALLATION; WARNING: A qualified service person must in-
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 6 AIR FOR COMBUSTION AND VENTILATION Ventilation Air INSTALLATION AIR FOR COMBUSTION ANDVENTILATION Continued VENTILATION AIR Ventila...
Page 7 - Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; LOG SIZING REQUIREMENTS; MINIMUM FIREPLACE; A. Clearances from the side of the fireplace opening to any com-; Figure 4 - Minimum Clearance for Combustible to Wall
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 7 7 INSTALLATION Check Gas Type Installation and Clearances WARNING: Never install the heater • in a bedroom or bathroom unless insta...
Page 8 - Minimum Noncombustible Material Clearances; If Not Using Mantel; If using a mantel, proceed to If Using Mantel. If not using a; If Using Mantel; If you cannot meet these minimum clearances, you; Installing Damper; Noncombustible material okay.
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 8 INSTALLATION Installation and Clearances (Cont.) INSTALLATION Continued Minimum Noncombustible Material Clearances If Not Using Man...
Page 9 - Determining Minimum Mantel Clearance; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain; Figure 6 - Minimum Mantel Clearances Without Using Hood; Figure 7 - Minimum Mantel Clearances When Using Hood
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 9 9 INSTALLATION Mantel Clearances Floor Clearances INSTALLATION Continued MANTEL CLEARANCES In addition to meeting noncombustible ma...
Page 10 - Area of Various Standard; Figure 10 - Attaching Damper Clamp; INSTALLING HEATER BASE ASSEMBLY; Installation Items Needed
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 10 INSTALLATION Installing Damper Clamp Accessory For Vented OperationInstalling Heater Base Assembly INSTALLATION Continued Area of ...
Page 11 - Remove heater base from fireplace.; Figure 12 - Attaching Base Assembly to Fireplace Floor; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; Figure 13 - External Regulator With Vent Pointing Down; WARNING: For natural gas units, never connect
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 11 11 INSTALLATION Installing Heater Base Assembly (Cont.) Connecting To Gas Supply INSTALLATION Continued 7. Mark screw locations th...
Page 12 - Install equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant; Figure 14 - Gas Connection; * Purchase the optional CSA design-certified equipment shutoff; Pressure Testing Gas Supply Piping System; Correct all leaks at once.; WARNING: Never use an open flame to check for; CHECKING GAS CONNECTIONS
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 12 INSTALLATION Connecting To Gas Supply (Cont.)Checking Gas Connections INSTALLATION Continued Installation must include a equipment...
Page 13 - Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Figure 15 - Equipment Shutoff Valve; WARNING: Failure to position the parts in accor-; Figure 18 - Installing Back Log
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 13 13 INSTALLATION Checking Gas Connections (Cont.) Installing Logs, Models CGS2718P, CGS2718N, CGS3124P and CGS3124N INSTALLATION Co...
Page 14 - Figure 19 - Installing Front Log
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 14 INSTALLATION Installing Logs, Models CGS2718P, CGS2718N, CGS3124P and CGS3124N (Cont.)Installing Logs, Models CLD3018PA, CLD3018NA...
Page 15 - OPERATING HEATER; WARNING: If you do not follow these instructions; FOR YOUR SAFETY READ
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 15 15 INSTALLATION Installing Logs, Models CLD3018PA, CLD3018NA, CLD3924PTA and CLD3924NTA (Cont.) OPERATING HEATER Manually-Controll...
Page 16 - OPERATING HEATER Manually-Controlled Models; LIGHTING INSTRUCTIONS; Figure 25 - Control Knob and Ignitor Button Location; VARIABLE CONTROL OPERATION; Natural Gas
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 16 OPERATING HEATER Manually-Controlled Models Lighting InstructionsVariable Control Operation OPERATING HEATER Continued WARNING: Do...
Page 17 - OPERATING HEATER Thermostatically-Controlled Models; Shutting Off Heater; THERMOSTATICALLY-CONTROLLED; WARNING
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 17 17 OPERATING HEATER Manually-Controlled Models To Turn Off Gas To Appliance Manual Lighting Procedure OPERATING HEATER Thermostati...
Page 18 - CAUTION: Do not try to adjust heating levels by; Figure 27 - Control Knob and Ignitor Button Location; TO TURN OFF GAS TO APPLIANCE; Shutting Off Burners Only (pilot stays lit); THERMOSTAT CONTROL OPERATION; Selecting the HI setting with the control knob will cause the; MANUAL LIGHTING PROCEDURE
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 18 OPERATING HEATER Thermostatically-Controlled Models Lighting Instructions (Cont.)To Turn Off Gas To ApplianceThermostat Control Op...
Page 19 - CLEANING AND MAINTENANCE; BURNER PRIMARY AIR HOLES; INSPECTING BURNERS; PILOT FLAME PATTERN; Figure 29 - Correct Pilot Flame Pattern; WARNING: Turn off heater and let cool before; Figure 31 - Injector Holder On Outlet Burner Tube
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 19 19 INSPECTING BURNERS Pilot Flame Pattern Burner Primary Air Holes Main Burner CLEANING AND MAINTENANCE ODS/Pilot And Burner Clean...
Page 20 - Figure 32 - Pilot Inlet Air Hole; TECHNICAL SERVICE; When Gas Pressure Is Too Low; REPLACEMENT PARTS
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 20 4. Check the injector holder located at the end of the burner tubeagain. Remove any large particles of dust, dirt, lint, or pet ha...
Page 21 - TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 21 21 TROUBLESHOOTING TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool beforeservicing. Only a qualified ser-vice p...
Page 22 - OBSERVED PROBLEM; nance, page 19) or replace burner orifice
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 22 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does light after ODS/pilot is lit Delayed ignition of burner Burner backfiring d...
Page 23 - IMPORTANT
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 23 23 TROUBLESHOOTING TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.•...
Page 24 - Do not remove the screw. Make sure you tighten the; OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 24 OPTIONAL POSITIONING OFTHERMOSTAT SENSING BULB For Masonry and Factory-built Metal Fireplace If your log set cycles to pilot, but ...
Page 25 - SPECIFICATIONS
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 25 25 SPECIFICATIONS SPECIFICATIONS 18" Model 18" Model 24" Model 24" model (CGS2718P) (CLD3018PA) (CGS3124P) (CLD392...
Page 26 - ILLUSTRATED PARTS BREAKDOWN
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 26 ILLUSTRATED PARTSBREAKDOWN Variable Manually-ControlledWinchester Oak Models CGS2718N, CGS2718PCGS3124N, CGS3124P 4 2 1 3 12 21 10...
Page 27 - PARTS LIST; KEY
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 27 27 PARTS LIST Models CGS2718N, CGS2718P, CGS3124N and CGS3124P PARTS LIST Variable Manually-Controlled WinchesterOak Models This l...
Page 32 - ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010; PARTS CENTRAL; FIREPLACE HOOD
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 32 ACCESSORIES Purchase these fireplace accessories from your local dealer. Ifthey can not supply these accessories, either contact y...
Page 33 - OWNER'S REGISTRATION FORM
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 33 33 1. Where will the product be used? ❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bath...
Page 34 - Postage
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 34 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 Postage Required TM
Page 35 - NOTES
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 35 35 NOTES _______________________________________________________________________________________________ _________________________...
Page 36 - KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; NOT A UPC
107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 36 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 www.desatech.com TM KEEP THIS WARRANTY WARRANTY INFORMATION Always...