Page 2 - PROPANE/LP GAS HEATER; WARNINGS; Carbon Monoxide Poisoning:; LOCAL CODES; Safety Device
2 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR SAFETYINFORMATION WARNINGS IMPORTANT: Read this owner’smanual carefully and completelybefore trying to assemble, oper-ate, or service this heater. Im-proper use of this heater cancause serious injury or death fromburns, fire, explosion, and car-...
Page 3 - OWNER’S MANUAL; Unusually Tight Construction; Confined and Unconfined Space; per
3 103547 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Vent-Free Propane/LP Gas Heater (Model CGP10L Shown) Control Knob HeaterCabinet GrillGuard GlassPanel FrontPanel Ignitor Button FRESH AIR FORCOMBUSTION ANDVENTILATION WARNING: This heater shall not be installed in a confinedspace unless provis...
Page 4 - WARNING: If the area in which; VENTILATION AIR; Includes the room in which you
4 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR WARNING: If the area in which the heater may be operated issmaller than that defined as anunconfined space, provide ad-equate combustion and ventila-tion air by one of the methodsdescribed in the National Fuel Gas Code, ANSI Z223.1, 1992,Section...
Page 5 - Figure 2 - Ventilation Air from Inside Building; Ventilation Air From Outdoors; Do not provide openings
5 103547 OWNER’S MANUAL FRESH AIR FORCOMBUSTION ANDVENTILATION Continued Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 Figure 2 - Ventilation Air from Inside Building Figure 3 - Ventilati...
Page 6 - Marking Screw Locations; Figure 5 - Mounting Screw Locations; WARNING: Maintain minimum; CHECK GAS TYPE; WARNING: Never install the
6 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR For convenience and efficiency, install heater • where there is easy access for operation, inspection, and service • in coldest part of room Figure 4 - Mounting Clearances As ViewedFrom Front of Heater INSTALLING HEATER TOWALL Marking Screw Loca...
Page 7 - Installing Two Mounting Screws; Wall anchors and mounting screws; Attaching to wall stud method; For attaching mounting screw to wall stud; Figure 6 - Folding Anchor; Figure 8 - Tightening Anchors; Removing Front Panel Of Heater; Mark screw location on wall.
7 103547 OWNER’S MANUAL Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack-age is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64"drill bit. 2. ...
Page 8 - Hold pressure regulator; Figure 13 - Gas Connection; CAUTION: Never connect
8 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR IMPORTANT: Hold pressure regulator with wrench when connecting it to gas pip-ing and/or fittings. Figure 13 - Gas Connection Tee Joint ReducerBushing to1/8" NPT 1/8" NPTPlug Tap TestGaugeConnection * TeeJoint PipeNipple Cap PressureRegul...
Page 9 - WARNING: Never use an open; Correct all leaks at once.; Figure 14 - Manual Shutoff Valve; Figure 15 - Checking Gas Joints; FOR YOUR SAFETY
9 103547 OWNER’S MANUAL CHECKING GASCONNECTIONS WARNING: Test all gas pip- ing and connections for leaksafter installation or servicing.Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply amixture of liquid soap and waterto all joints. Bubbles formingshow a leak. C...
Page 10 - Pilot Burner; Figure 19 - Incorrect Pilot Flame Pattern; • turn heater off (see To Turn Off Gas to; Figure 18 - Correct Pilot Flame Pattern; Shutting Off Heater
10 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR GRH/OV 008 BAD PILOT/LP TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figure 10,page 7). 2. Follow steps 1 through 5 under Light-ing Instructions. 3. With control knob pressed in, strikematch. Hold match to pilot until pi-lot lights. ...
Page 11 - BURNER FLAME PATTERN; If burner flame pattern is incorrect, as shown in Figure 21; Figure 20 - Correct Burner Flame Pattern; CABINET; Air Passageways; • Use a vacuum cleaner or pressurized air; Exterior; • Use a soft cloth dampened with a mild
11 103547 OWNER’S MANUAL BURNER FLAME PATTERN Figure 20 shows a correct burner flamepattern. Figure 21 shows an incorrect burnerflame pattern. The incorrect burner flamepattern shows yellow tipping of the flame. Italso shows the flame higher than 1/2 theglass panel height. NOTICE: Do not mistake ora...
Page 12 - All troubleshooting items; TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE
12 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR Note: All troubleshooting items are listed in order of operation. TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Onlya qualified service person shouldservice and repair heater. POSSIBLE CAUSE 1. Ignitor electrode positi...
Page 13 - OBSERVED PROBLEM
13 103547 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial opera-tion Heater produces a whistling noise whenburner is lit Heater produc...
Page 14 - SERVICE HINTS; IMPORTANT; REMEDY; ACCESSORY
14 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR You may have further questions about in-stallation, operation, or troubleshooting. If so, contact DESA International’s Techni-cal Service Department at 1-800-323-5190. TECHNICALSERVICE SERVICE HINTS When gas pressure is too low • pilot will not...
Page 15 - Parts Under Warranty; SPECIFICATIONS
15 103547 OWNER’S MANUAL CGP6L CGP10L Btu (Variable) 4,400/6,000 5,000/10,000 Type Gas Propane/LP Only Propane/LP Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 8" W.C. Inlet Gas Pressure (inches of water) Maximum 14" 14" Minimum 11" 11" Dimensions, Inches (H x ...
Page 16 - HEATER EXPLODED VIEW
16 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR 10 12 11 1 2 3 4 5 6 7 9 8 GRHpv014C CGP10 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 HEATER EXPLODED VIEW CGP10L CGP6L 12-2 12-1 ODS/PILOT ILLUSTRATEDPARTS LIST
Page 17 - PARTS LIST; PART NUMBER FOR
17 103547 OWNER’S MANUAL PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow theinstructions listed under Replacement Parts on page 15 of this manual. PART NUMBER FOR CGP6L CGP10L KEY NO. DESCRIPTION QTY. 1 098304-01 098304-01 Screw, #10 x 3/8" 2 2 09...
Page 18 - NOTES
18 103547 PROPANE/LP GAS HEATER 10,000 AND 6,000 BTU/HR NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ ______________________________________________...
Page 20 - KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:; INTERNATIONAL; NOT A UPC
KEEP THIS WARRANTY WARRANTY INFORMATION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standardwritten warranty. We make no other warranty, expressed or im...