Page 2 - NATURAL GAS HEATER; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
2 101870 NATURAL GAS HEATER CGN10A AND CGN6 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re-semble the flu, with headaches, dizziness,or nausea. If you have these signs, the heatermay not be working properly. Get fresh airat once! Have heater serviced. Some peopleare more affe...
Page 3 - OWNER’S MANUAL; LOCAL CODES; American National Standards Institute,; Remove heater from carton.; Safety Device; UNPACKING; WARNING: This heater shall
3 101870 OWNER’S MANUAL PRODUCTIDENTIFICATION Control Knob LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes,use the latest edition of The National FuelGas Code ANSI Z223.1, also known asNFPA 54*. *Available from: American National Standards Institute...
Page 4 - Unusually Tight Construction; Gas water heater
4 101870 NATURAL GAS HEATER CGN10A AND CGN6 WARNING: If the area in which the heater may be operated issmaller than that defined as anunconfined space, provide ad-equate combustion and ventila-tion air by one of the methodsdescribed in the National Fuel Gas Code, ANSI Z223.1, 1992,Section 5.3 or app...
Page 5 - Figure 2 - Ventilation Air from Inside Building; VENTILATION AIR; Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings
5 101870 OWNER’S MANUAL FRESH AIR FORCOMBUSTION ANDVENTILATION Continued Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 WARNING: Rework work- sheet, adding the space of theadjoining unconf...
Page 6 - Marking Screw Locations; Determine where you will locate heater.; Figure 5 - Mounting Screw Locations; JOINING WALL; • where there is easy access for op-; CHECK GAS TYPE
6 101870 NATURAL GAS HEATER CGN10A AND CGN6 Continued 2. Mark two mounting screw locations onwall (see Figure 5). INSTALLING HEATER TOWALL Marking Screw Locations 1. Determine where you will locate heater. Figure 5 - Mounting Screw Locations Mounting Screw Locations 8 7/8" Minimum To Maintain 6&...
Page 7 - Installing Two Mounting Screws; Wall anchors and mounting screws; Attaching to wall stud method; For attaching mounting screw to wall stud; Figure 8 - Tightening Anchors; Removing Front Panel Of Heater; Mark screw location on wall.
7 101870 OWNER’S MANUAL ANCHOR Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack-age is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64"drill b...
Page 8 - Figure 12 - Gas Connection; Check gas line pressure; WARNING: Never connect
8 101870 NATURAL GAS HEATER CGN10A AND CGN6 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/ or fittings. * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptablealternative to test gauge connection. Purchase the optional A.G.A. des...
Page 9 - WARNING: Never use an open; Correct all leaks at once.; Figure 13 - Manual Shutoff Valve; Figure 14 - Checking Gas Joints
9 101870 OWNER’S MANUAL Gas Meter CHECKING GASCONNECTIONS WARNING: Test all gas pip- ing and connections for leaksafter installing or servicing. Cor-rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply amixture of liquid soap and waterto all joints. Bubbles formingshow...
Page 10 - Shutting Off Heater; CAUTION: Do not try to adjust
10 101870 NATURAL GAS HEATER CGN10A AND CGN6 TO TURN OFF GASTO APPLIANCE Shutting Off Heater 1. Turn control knob clockwise to the PILOT position. 2. Press in control knob and turn clock-wise to the OFF position. Shutting Off Burner Only (pilotstays lit) 1. Turn control knob clockwise to the PILOT p...
Page 11 - PILOT FLAME PATTERN; Figure 17 - Correct Pilot Flame Pattern; BURNER FLAME PATTERN; WARNING: If yellow tipping; Figure 20 - Incorrect Burner Flame Pattern; CABINET; Air Passageways; WARNING: Turn off heater
11 101870 OWNER’S MANUAL Check pilot flame pattern and burner flamepattern often. PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pat-tern. Figure 18 shows an incorrect pilotflame pattern. The incorrect pilot flame isnot touching the thermocouple. This willcause the thermocouple to cool. W...
Page 12 - TROUBLESHOOTING; OBSERVED PROBLEM
12 101870 NATURAL GAS HEATER CGN10A AND CGN6 TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Onlya qualified service person shouldservice and repair heater. CAUTION: Never use a wire, needle, or similar object ...
Page 14 - REMEDY; IMPORTANT
14 101870 NATURAL GAS HEATER CGN10A AND CGN6 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow...
Page 15 - When gas pressure is too low; SERVICE HINTS; Parts Under Warranty
15 101870 OWNER’S MANUAL TECHNICALSERVICE You may have further questions about in-stallation, operation, or troubleshooting. If so, contact DESA International’s Techni-cal Service Department at 1-800-323-5190. CGN6 CGN10A Btu (Variable) 4,400/6,000 5,000/10,000 Type Gas Natural Only Natural Only Ign...
Page 16 - HEATER EXPLODED VIEW
16 101870 NATURAL GAS HEATER CGN10A AND CGN6 12-2 12-1 ODS/PILOT HEATER EXPLODED VIEW 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 23 24 27 22 26 25 19 20 28 29 ILLUSTRATEDPARTS LIST
Page 17 - PARTS LIST; PART NUMBER FOR
17 101870 OWNER’S MANUAL PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructionslisted under Replacement Parts on page 15 of this manual. PART NUMBER FOR CGN6 CGN10A KEY NO. DESCRIPTION QTY. 1 098304-01 098304-01 Screw, #10 x 3/8" 2 2 099...
Page 18 - PARTS CENTRALS
18 101870 NATURAL GAS HEATER CGN10A AND CGN6 PARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support ourcustomer’s needs by providing original replacement parts and accessories. Baltimore Electric1348 Dixwell AvenueHamden, CT 065141-800-397-7553203-248-7553Par...
Page 19 - NOTES
19 101870 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________________________________________...
Page 20 - LIMITED WARRANTY; For information about this warranty write:; WARRANTY INFORMATION; KEEP THIS WARRANTY
Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is ourstandard written warranty. We make no other warranty, expressed or implied. L...