Page 2 - GENERAL SPECIFICATIONS; MODEL; POWER SOURCE; TABLE OF CONTENTS
2 GENERAL SPECIFICATIONS MODEL ITEM POWER SOURCE DIMENSIONS WEIGHT DWC-051C 52.2 Ibs (23.7 Kg)-Approx. DWC-072C DWC-073C DWC-092C DWC-094C AC 115V, 60Hz, SINGLE PHASE 64 Ibs (29 Kg)- Approx. 63 Ibs (28.5 Kg)-Approx. 18.9(W) x 14.6(H) x 19.5(D) inch 480(W) x 369(H) x 497(D) mm 1. GENERAL SPECIFICATIO...
Page 3 - INSTALLATION INSTRUCTIONS; • WINDOW REQUIREMENTS
3 INSTALLATION INSTRUCTIONS • WINDOW REQUIREMENTS These instructions are provided for a standard double hung window or mobile home double hung window installation in windows 24 inch (610mm) to 36 in (914mm). The upper and lower sash must open sufficiently to allow a clear vertical opening of 15 in (...
Page 4 - for the power cord to reach it.; • BEFORE INSTALLATION; Test Run Unit : Plug unit into proper power supply outlet.; unit with front grille removed .
4 • SAFETY INSTRUCTIONS (CONTINUED) The receptacle should be an individual branch circuit used only for this air conditioner. Be sure the electrical service is adequate for the model air conditioner you have chosen. The complete electrical rating of your air conditioner is stated on the name plate l...
Page 7 - • Step 4 - Placing Chassis; Insert narrow side of ‘Frame Guide Lower’ to rectangle holes; • Step 5 - Secure Window Shutter; To provide a proper seal, pull each expandable side Window Shutter; CAUTION Do not drill into window sash until window has
7 • Step 4 - Placing Chassis 1. Insert narrow side of ‘Frame Guide Lower’ to rectangle holes located in bottom of chassis, and fasten it with Screw (Type D). 2. Insert Window Kit Frames to Top Guide and Lower Guide.3. Fasten Shutter to side holes of Chassis with six Screws (Type D).4. Place the chas...
Page 8 - – Snap Front Grille’s hook to each Chassis holes.; • Step 8 - Recheck the entire installation
8 • Step 6 - Recheck Installation To be sure you have correctly installed your Room Air Conditioner, review the steps and make sure all of theparts are securely fastened in the window as the instructions show. A tight seal is essential.Read through the Use & Care manual to become familiar with t...
Page 9 - NAMES OF MAJOR COMPONENTS
9 NO PART NAME 1 CABINET 2 BLADE VERTICAL 3 BLADE HORIZENTAL 4 KNOB BLADE 5 GRILLE FRONT 6 KNOB SELECTOR NO PART NAME 7 KNOB THERMOSTAT 8 AIR FILTER 9 CONTROL PANEL 10 FRAME GUIDE TOP 11 FRAME WINDOW KIT 12 SHUTTER WINDOW NAMES OF MAJOR COMPONENTS • DWC-051C / DWC-072C / DWC-073C / DWC-092C / DWC-09...
Page 10 - OPERATING INSTRUCTIONS
10 • FAN & COOLING CONTROL The Fan Control Selector Switch has five positions.Choose one of the speed settings by rotating the fan control Selector Switch to the appropriate position. OFF Select this setting for stop all operation of air conditioner HIGH FAN Select this setting for maximum air c...
Page 11 - • CHANGING AIR FLOW DIRECTION; Adjust deflectors for desired air flow pattern.; • AIR FLOW AROUND UNIT; early compressor failure.; • DRAIN HOLE AND WATER DRIPPING OUTSIDE; GENERAL INFORMATION
11 • CHANGING AIR FLOW DIRECTION Air flow deflectors divert air from center flow to left or right and up or down. Adjust deflectors for desired air flow pattern. • AIR FLOW AROUND UNIT Check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outd...
Page 12 - • AIR FILTER; Shake it when clean to remove moisture completely. Reinstall.; • CLEANING THE AIR CONDITIONER; At least once a year, remove cabinet and thoroughly clean air; CARE AND MAINTENANCE; CAUTION
12 • AIR FILTER Clean the air filter, which removes dust inside the room.It should be washed at least once every week during operation.1. Remove the Air Filter from the front grill by pulling up.2. Clean Air Filter with a vacuum cleaner or lukewarm, soapy water. 3. Shake it when clean to remove mois...
Page 13 - • ELECTRICAL GROUNDING INSTRUCTIONS; with the National Electrical Code.; • USE OF EXTENSION CORD; ELECTRICAL REQUIREMENTS; Do not use a two prong adapter.
13 • ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replac...
Page 14 - BEFORE CALLING FOR SERVICE; Difficulty
14 BEFORE CALLING FOR SERVICE When you find something wrong with your room air conditioner, please carefully check the following items. If you are unable to find the cause of trouble, contact your service dealer. Difficulty • Air conditioner does not operate. • Little or no cooling • Noisy unit • Or...
Page 15 - Limited Warranty
Limited Warranty DAEWOO ELECTRONICS CORPORATION OF AMERICA warrants the followingwindow room air-conditioner to be free from defective material and workmanship andagrees to remedy any such defect or to furnish a new part (at the Company’s option) inexchange for any part of any unit of its manufactur...
Page 16 - WINDOW TYPE ROOM AIR CONDITIONER
MODEL #: DWC-051CDWC-072CDWC-073CDWC-092CDWC-094C ROOM AIR CONDITIONERUSE & CARE MANUAL WINDOW TYPE ROOM AIR CONDITIONER W1 R C US LISTED UL and CUL listed Please read carefully and thoroughly this manual beforeoperating the unit.If you still have any difficulties or problems, consult your deale...