Page 2 - CyberPower ATT3612V3S (Leave Behind Manual); TABLE OF CONTENTS; LED; TABLE OF FIGURES; Customer Battery Replacement ........................................................................ 9-10; TABLE OF TABLES
CyberPower ATT3612V3S (Leave Behind Manual) Page: 2 of 11 TABLE OF CONTENTS 1 PRODUCT INTRODUCTION .................................................................................................................3 1.1 G ENERAL D ESCRIPTION ...............................................................
Page 3 - PRODUCT INTRODUCTION; The
CyberPower ATT3612V3S (Leave Behind Manual) Page: 3 of 11 1 PRODUCT INTRODUCTION 1.1 General Description The ONT-BBPSU (Optical Network Terminal Uninterruptable Battery Backup Power Supply Unit) is designed to be mounted inside a customer premises and provides power to the ONT. The Optical Network T...
Page 4 - IMPORTANT SAFETY NOTES; power connected. Use extreme caution during these procedures.; Battery Warnings
CyberPower ATT3612V3S (Leave Behind Manual) Page: 4 of 11 2 IMPORTANT SAFETY NOTES ONLY qualified installation and repair personnel should service this power supply. SAVE THESE INSTRUCTIONS - This manual contains important instructions for the ATT3612V3S units that should be followed during inst...
Page 5 - replacing batteries.; Safety Warning Label; Figure 2: Warning Label; Power Supply
CyberPower ATT3612V3S (Leave Behind Manual) Page: 5 of 11 Wear protective clothing and eye protection whenever installing, maintaining, servicing, or replacing batteries. If any battery emission contacts the skin, immediately and thoroughly wash with water. Follow approved chemical exposure proc...
Page 6 - POWER SUPPLY OVERVIEW; Power Cable
CyberPower ATT3612V3S (Leave Behind Manual) Page: 6 of 11 3 POWER SUPPLY OVERVIEW 3.1 Overview Figure 3: Unit Overview (Front) 1. Control Buttons (Alarm Silence) 2. LED Indicators (System Status/Battery Power/Replace Battery/Auxiliary Power Source) 3. Battery Input Power Connector 4. 7 Pin Connector...
Page 7 - Figure 4: Front Panel LED and Controls; Function Symbol Type; Push; Operational LEDs; Indicator Color; Table 2: LED Indicators
CyberPower ATT3612V3S (Leave Behind Manual) Page: 7 of 11 4 OPERATION 4.1 Start-Up Make sure that the battery connector is plugged in, the battery is locked into place, and the battery door is closed. Plug the ATT3612V3S power supply into AC power. The LED of system status showing green indicates no...
Page 8 - Auxillary Power Connection; Figure 5: Auxiliary Power Connection; Alarms; LEDs Condition Status
CyberPower ATT3612V3S (Leave Behind Manual) Page: 8 of 11 4.4 Auxillary Power Connection Figure 5: Auxiliary Power Connection Connection point for customer-supplied DC input voltage shall be 12Vdc. After depleting the on-board battery capacity, the ATT3612V3S will utilize power from a valid and pres...
Page 9 - MAINTENANCE; Figure 6
CyberPower ATT3612V3S (Leave Behind Manual) Page: 9 of 11 5 MAINTENANCE 5.1 Maintenance Mode Maintenance mode determines remaining useful battery life. If the remaining battery life is determined to be below an acceptable level and unable to support proper operation, the Replace Battery LED will be ...
Page 10 - Figure 8
CyberPower ATT3612V3S (Leave Behind Manual) Page: 10 of 11 Figure 8 Battery Type The battery is a standard sealed lead acid battery rated at 12Vdc / 7.2Ah. When required, the battery may be replaced with an approved 12Vdc / 7.2Ah battery. Batteries are considered HAZARDOUS WASTE and must be disposed...
Page 11 - SPECIFICATIONS; Table 4: Specifications
CyberPower ATT3612V3S (Leave Behind Manual) Page: 11 of 11 6 SPECIFICATIONS Table 4: Specifications