Page 2 - TABLE OF CONTENTS
i 620918702 TABLE OF CONTENTS SAFETY INFORMATION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RECOGNIZE SAFETY INFORMATION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNDERSTAND SIGNAL WORDS 1 . . . . . . . . . ...
Page 4 - SAFETY INFORMATION; Recognize Safety Information; CAUTION; Understand Signal Words; WARNING; Follow Safety Instructions
1 620918702 SAFETY INFORMATION Recognize Safety Information This is the safety-alert symbol. When you see thissymbol on our machine or in this manual, be alert tothe potentially of personal injury. Follow recommended precautions and safe operatingpractices. CAUTION DANGER Understand Signal Words A s...
Page 6 - SAFETY PRECAUTIONS; SPECIFICATIONS
3 620918702 SAFETY PRECAUTIONS This dispenser has been specifically designed to provide protection against personal injury and eliminate contamination of the ice. To ensure continued protection and sanitation , observe the following. ALWAYS: Disconnect electrical power from the dispenser before serv...
Page 8 - INSTALLATION INSTRUCTIONS; COUNTERTOP INSTALLATION
5 620918702 INSTALLATION INSTRUCTIONS COUNTER HEIGHT (INCHES) DISPENSER DEPTH (INCHES AVAILABLE SPACE BELOW DISPENSER (INCHES) USE KIT NO. 30 29 1 CONSULT FACTORY 31 29 2 CONSULT FACTORY 32 29 3 620517502 AND 629087406 33 29 4 629087406 34 29 5 629087406 34–1/2 29 5–1/2 629087412 AND 620517502 35 29...
Page 12 - MAINTENANCE; MONTHLY; ADJUSTING DISPENSING VALVES WATER FLOW RATE
9 620918702 MAINTENANCE The following dispenser maintenance should be performed at the intervals indicated. DAILY (or as required) Remove foreign material from the vending area drip tray to prevent drain blockage. Clean vending area. Checkfor proper water drainage from the vending area drip tray. MO...
Page 14 - START–UP AND OPERATING INSTRUCTIONS
11 620918702 2. Install syrup diversion tube assembly on the dispensing valve by pushing the rubber end of the syrup diver- sion tube onto the syrup outlet of the inner nozzle. Notice: Refer to syrup manufacturer ’s recommendations on syrup package for water-to-syrup ratio. 3. Dispense enough to fil...
Page 15 - CLEANING AND SANITIZING INSTRUCTIONS; Cleaning Dispenser
12 620918702 69 66 67 65 73 77 FIGURE 4. AUGER ASSEMBLY CLEANING AND SANITIZING INSTRUCTIONS WARNING: Disconnect electrical power to the dispenser before cleaning. Do not use metalscrapers, sharp objects, or abrasives on the ice storage hopper, top cover, and the agitatordisk as damage may result. D...
Page 18 - ICE AUGER SPEED CONTROL
15 620918702 11. For post-mix valves, remove the nozzle and syrup diffuser and clean them in a mild soap solution. Rinse with clean water and reassemble the nozzle and syrup diffuser on the valve. 12. For pre-mix valves, disconnect all product tubes from the tank of sanitizing solution and then open...
Page 22 - TROUBLESHOOTING
19 620918702 TROUBLESHOOTING IMPORTANT: Only qualified Personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to a syrup system, disconnect syrup supply from theapplicable syrup system, then relieve the system pressure before proceeding. If repairs aret...
Page 24 - ILLUSTRATED PARTS LIST
21 620918702 ILLUSTRATED PARTS LIST 1 2 3 4 128 139 6 17 11 58 13 34 9 59 122 133 79 118 89 78 87 114 142 141 134 86 115 116 96 85 98 121 24. 74 75 101 136 105 110 112 109 83 88 9 117127 103 80 90 16 82 92 77 95 48 93 31 93 31 93 13 35 33 29 31 93 36 35 16 40 95 53 52 33 93 35 41 42 36 137 31 93 35 ...
Page 31 - WARRANTY
28 620918702 WARRANTY IMI Cornelius Inc. Products Company warrant that all equipment and parts are free from defects in material andworkmanship under normal use and service. For a copy of the warranty applicable to your Cornelius product, inyour country, please write, fax or telephone the IMI Cornel...