Page 2 - Quest Juice Training Manual
Quest Juice Training Manual The products, technical information, and instructions contained in this manual are subject to change without notice. These instructions are not intended to cover all details or varia-tions of the equipment, nor to provide for every possible contingency in the installation...
Page 3 - TABLE OF CONTENTS
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - i - Publication Number: TP00968 TABLE OF CONTENTS Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product Description . . . . . . . . . . . . . . . . . . . . ...
Page 5 - OVERVIEW; RODUCT
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 1 - Publication Number: TP00968 OVERVIEW P RODUCT D ESCRIPTION The Quest Juice Dispenser uses an ice/water bath system to cool both the potable water supply and the concentrate cabinet. To achieve cooling capabilities we use an agitator/recalc...
Page 6 - IMENSIONS; Quest
Quest Juice Training Manual Publication Number: TP00968 - 2 - © 2004, IMI Cornelius Inc. D IMENSIONS & C APACITIES Quest Dispense Rate ........................................ 1.0 – 2.2 oz./sec. Electrical rating ....................................... 115 VAC, 60 Hz, 15 amp dedicated circuit .....
Page 7 - SYSTEM DETAILS; ATER; Water Quality; ONCENTRATE
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 3 - Publication Number: TP00968 SYSTEM DETAILS W ATER Water Quality Water quality has an affect on juice dispensing systems. • odor• taste• clarity/foaming Water filtration is recommended to assure the best beverage taste. Water Flow Inlet wat...
Page 8 - INTRODUCTION; REVIEW; EY
Quest Juice Training Manual Publication Number: TP00968 - 4 - © 2004, IMI Cornelius Inc. INTRODUCTION P REVIEW Q UESTIONS Check your current knowledge by taking a few minutes to answer the following questions: 1 . The ice bank control is adjustable? _____ True _____ False 2 . The transformer does NO...
Page 9 - INSTALLATION
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 5 - Publication Number: TP00968 INSTALLATION C OUNTER L OCATION The minimum airflow clearance is: 4” (10.16 cm) in back and 12” (30.48 cm) on top and open to the front. IMPORTANT: Condenser air is drawn in from the bottom of the rear panel and...
Page 10 - CONCENTRATE HANDLING & LOADING; OADING; HANGING
Quest Juice Training Manual Publication Number: TP00968 - 6 - © 2004, IMI Cornelius Inc. CONCENTRATE HANDLING & LOADING It is recommended that the concentrate be thawed in a refrigerated 35 ° F-40 ° F (1.6 ° C-4.4 ° C) compart- ment for a minimum of 48 hours prior to loading into the Quest Juice...
Page 11 - BRIXING PROCEDURE
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 7 - Publication Number: TP00968 BRIXING PROCEDURE NOTE: If concentrate is not properly thawed, it will adversely affect the amount of concentrate dispensed. Thawed product should be between 35 ° F/1.6 ° C to 40 ° F/4.4 ° C. NOTE: You can not d...
Page 12 - ROGRAMMING
Quest Juice Training Manual Publication Number: TP00968 - 8 - © 2004, IMI Cornelius Inc. Pump Speed Switch The pump speed switch has two settings, low and high. For most dispensing situations high speed will be the preferred speed. Most concentrates use this setting. Low speed is only used when the ...
Page 13 - PLANNED MAINTENANCE SCHEDULE; AILY; Sanitize the Juice Dispenser:
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 9 - Publication Number: TP00968 PLANNED MAINTENANCE SCHEDULE D AILY Flush System: 1. Move Dispense/Flush levers located on the platform assembly in the refrigerated cabinet to the “Flush” position. Place an empty cup on the drip tray below eac...
Page 14 - EMI; Clean Water Inlet Strainer:
Quest Juice Training Manual Publication Number: TP00968 - 10 - © 2004, IMI Cornelius Inc. Step 2 - Sanitize Pump System 1. Fill a clean concentrate container with 2 quarts (1.9L) of fresh sanitizing solution. 2. Place handles in the “dispense” position and close the door. 3. Press and hold the dispe...
Page 15 - NNUALLY; Replacing Pump Tubing:
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 11 - Publication Number: TP00968 A NNUALLY Replace Pump Tubing: A replacement pump tubing kit, part#45098, is available. The kit consists of one pre-cut length of pump tubing, two white plastic hose clamps, and instructions. Removing Pump Plat...
Page 17 - MECHANICAL SECTION; EMOVAL
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 13 - Publication Number: TP00968 MECHANICAL SECTION R EMOVAL OF M ERCHANDISER 1. Remove (6) screws from the top, the front, and the side of the door (as shown). NOTE: You now have access to the ballast and light panel. NOTE: Remember the door ...
Page 24 - VRB B; OARDS
Quest Juice Training Manual Publication Number: TP00968 - 20 - © 2004, IMI Cornelius Inc. R EMOVAL OF THE VRB B OARDS 1 . Remove the cover. 2 . Remove the connectors.3 . Loosen and remove the nut and insulation. 4 . Turn the box over and locate the standoffs on the VRB board to be removed. Gently sq...
Page 31 - MAJOR COMPONENT REVIEW; LECTRICAL
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 27 - Publication Number: TP00968 MAJOR COMPONENT REVIEW E LECTRICAL B OX The electrical box houses the Voltage Regulator Boards (VRB) that is used to convert AC voltage from the transformer to DC voltage that powers the pumping system. It also...
Page 32 - Operational Overview
Quest Juice Training Manual Publication Number: TP00968 - 28 - © 2004, IMI Cornelius Inc. P UMP S PEED S WITCH The pump speed switch has two settings, low and high. For most dispensing situations high speed will be the preferred speed. Most concentrates use this setting. Low speed is only used when ...
Page 34 - Water Valve/Flow Control
Quest Juice Training Manual Publication Number: TP00968 - 30 - © 2004, IMI Cornelius Inc. D OOR S WITCH - 72 E S ERIAL N UMBER P LATFORM C OMPONENTS On or before April 1, 2004 the door switch con-figuration will be changed to separate the reset switch from the catch. The serial number for this will ...
Page 35 - Bottle Adaptor - Sold Out Sensors
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 31 - Publication Number: TP00968 Tip: When re-assembling the large o-ring may be pinched if not installed properly. Place the slide valve into the bottom of the adaptor keeping straight across. Press evenly to seat the o-ring. It is not advisa...
Page 36 - Bottle Adaptor - Flush Mode
Quest Juice Training Manual Publication Number: TP00968 - 32 - © 2004, IMI Cornelius Inc. Bottle Adaptor - Flush Mode THE FLUSH MODE IS FOR FLUSHING THE PUMP SYSTEM OF CONCENTRATE ONLY. Dispensing water in the flush mode over long periods can cause the pump tubing to split at the inlet of the pump. ...
Page 37 - IRING
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 33 - Publication Number: TP00968 W IRING D IAGRAM
Page 39 - TROUBLESHOOTING GUIDE
Quest Juice Training Manual © 2004, IMI Cornelius Inc. - 35 - Publication Number: TP00968 TROUBLESHOOTING GUIDE The following pages contain troubleshooting information intended to aid an experienced service person in diagnosing operational problems that may occur. For further assistance, contact the...
Page 42 - NOTES
Quest Juice Training Manual Publication Number: TP00968 - 38 - © 2004, IMI Cornelius Inc. NOTES _______________________________________________________________________ _______________________________________________________________________ ____________________________________________________________...