Page 2 - Unpacking
2 SAFE USE INTRODUCTION • The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, do not mix blades from different cartons. • Inspect the contents of your carton for possible shipping or handling damage. If parts are missing or da...
Page 3 - ANDELIER; MOUNTING RECOMMENDATIONS; Location; • Do not install the fan in a doorway or above a swinging door.; GENERAL GUIDELINES; SLOPED CEILING INSTALLATIONS
3 C ANDELIER ™ MOUNTING RECOMMENDATIONS Before mounting your Casablanca Candelier, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every r...
Page 4 - Using Existing Ceiling Fixture Outlet Box; NOTE: The weight of this fan is approximately 150 pounds.; CROSSBAR HANGING BRACKET INSTALLATION; PARTS NEEDED FOR THIS SECTION:
4 GETTING STARTED FAN INSTALLATION Using Existing Ceiling Fixture Outlet Box After turning the power OFF at its source (either the circuit breaker or fuse box), lower the old fi xture and disconnect the wiring. The Candelier is not to be supported by the ceiling box. It must be directly mounted to t...
Page 5 - CANOPY BRACKET INSTALLATION; Option 1: Using Wood Screws; INSTALLING CANOPY COVER
5 C ANDELIER ™ CANOPY BRACKET INSTALLATION Step 2a. Hold the canopy bracket up to the ceiling with the ‘lip’ side facing the fl oor. Use a pen or pencil to mark screw placement through the holes in the bracket. Step 2b. Insert three black rubber grommets to the canopy bracket as shown. The bracket i...
Page 7 - CANOPY ELECTRICAL CONNECTIONS
7 C ANDELIER ™ Step 6a. Attach the fan wires (coming from the downrod) to the ceiling fi xture outlet box wiring by placing the bare ends of the wires side by side and then securing with a wire nut. Test that the connection is secure by pulling on the wire nut. Connect in this order: • GREEN wire le...
Page 9 - SAMPLE; Carefully remove candles from packaging materials.; CANDLE INSTALLATION
9 C ANDELIER ™ SAMPLE When you have used the fi ve extra fl icker bulbs included with your Candelier fan, Casablanca will provide fi ve additional spares at no charge. Simply complete this card, place it in the Extra Bulbs box with fi ve burned-out fl icker bulbs, seal the box, apply the pre-paid Bu...
Page 11 - POWER
11 C ANDELIER ™ The POWER button is nor mally left in the on position. Always tur n the power off during cleaning or ser vicing the fan and during thunderstor ms. It is also used to exit or enter additional programs. POWER must be left on to retain a previously set fan speed. POWER There are four in...
Page 12 - CARE RECOMMENDATIONS; Fan Finishes; applied for added protection and beauty.; No Need for Lubrication; • Do not attempt to oil the motor.; Changing Lightbulbs; order replacement bulbs.
12 CARE RECOMMENDATIONS Fan Finishes • For cleaning, a soft brush or lint-free cloth should be used to prevent scratching the fi nish. • Surface smudges or an accumulation of dirt and dust can be removed easily using a mild detergent and slightly dampened soft cloth. An antistatic agent may be used ...
Page 13 - PROBLEM POSSIBLE; TROUBLESHOOTING TIPS
13 C ANDELIER ™ PROBLEM POSSIBLE REMEDIES Fan will not start • Check the main circuit fuses, circuit breakers, and wall switch position. Check all wire connections. Make sure the power is turned off during this inspection. • The fan receiver is defective. Replace the fan receiver. • Check the freque...
Page 14 - PRODUCT SPECIFICATIONS; Candelier; Lighting; This device may not cause harmful interference.
14 For questions or to locate the nearest Casablanca Authorized Service Center call toll free: 1-888 -227-2178 or visit us on the Web at: www.casablancafanco.com PRODUCT SPECIFICATIONS Model name: Candelier ™ Model number: C16GxxT Dimensions: A = 15.44"B = 10.93" C = 13.44" as sold "...
Page 15 - AUTHORIZED SERVICE CENTERS
15 C ANDELIER ™ STATE/CITY ZIP SERVICE CENTER NAME PHONE TYPE ALABAMA MOBILE 36618 AZALEA CITY SERVICE CTR. 251-341-0663 FFS TUSCALOOSA 35405 LIGHTING PLUS 205-345-8900 FFS ALASKA ANCHORAGE 99518 BERING SEA ECCOTECH 907-227-3171 FFS ARIZONA GREEN VALLEY 85614 GOBLE ELECTRIC 520- 625- 4938 IHO MESA 8...