Page 2 - does not; Fig. 1 — Indoor and Outdoor Unit Components
2 GENERAL The high wall fan coil unit provides quiet, maximum comfort. In addition to cooling and/or heating, the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort. See Fig. 1. The high wall fan coil unit can be ...
Page 3 - Fig. 2 — High Wall Fan Coil Unit and Remote Control
3 The remote control can perform the following functions:• Turn the system ON and OFF • Select operating mode • Adjust room air temperature set point and fan speed • Set time periods for automatic system operationBATTERY INSTALLATION — Two AAA 1.5-v alkaline batteries (included) are required for ope...
Page 4 - Fig. 4 — Remote Control Display Icons
4 SETTING THE TIME ON THE REMOTE CONTROL (Current Time Adjusting C and Reset Buttons) — Press cur- rent time adjusting button C to adjust the current time. Press the reset button with the tip of a pen or a paperclip if the re- mote control is not operating properly or after replacing the batteries. ...
Page 5 - Table 1 — Louver Positions; Emergency Operation —; SYMBOL ON; Fig. 5 — Operating Mode Indicators on Remote Control
5 Table 1 — Louver Positions Indoor Unit Display (Fig. 7) — The indoor unit dis- play has three LED indicators at the lower right hand portion of the unit. The Blue light is illuminated when the ionizer is active. The Orange light is illuminated during timer mode. The Green light is illuminated duri...
Page 6 - Fig. 7 — Unit Display and Switch Panel
6 Selecting an Operating Mode — Use the button to select the unit operating mode. Repeatedly press the Operating Mode button to select avail- able modes. The chosen mode is shown as follows, while the unit will acknowledge signal receipt with a beep. Indicated symbol: Fan Only Heating Automatic Cool...
Page 7 - SYMBOL; Fig. 9 — Using the Vertical Guide Vane
7 LEFT AND RIGHT CONTROL — To adjust the direction of the discharge air to the left or right, adjust the vertical guide vane with the handle after opening the louver. See Fig. 9.NOTE: • Do not set the louver to position for long periods of time, because this position minimizes air circulationresulti...
Page 9 - Fig. 10 — Set Temperature Levels
9 Using the Ionizer Function — The ionizer helps to eliminate odors in the conditioned space. 1. Press to activate the Ionizer function. 2. Press again to turn off Ionizer function. Remote Control Address Selection — If two in- door units are in the same room, one remote control can be linked to one...
Page 10 - Table 2 — Periodic Maintenance; do not
10 Air Filters — Remove and clean the air filters once a month.NOTE: If air filters show signs of excessive wear or are torn, they must be replaced. Contact your local dealer for replace- ment filters. 1. Open front panel on unit.2. Pull filters down to remove.3. Vacuum filters.4. Clean with warm wa...
Page 11 - Table 3 — Troubleshooting; Table 4 — Unit Protection Devices
11 Table 3 — Troubleshooting LEGEND Table 4 — Unit Protection Devices Fill out the following to save time on any future service calls. Dealer’s Name _____________________________________________________________________________________________ Address _________________________________________________...