Page 2 - LOCATE UNIT; TABLE 1 – STANDARD PARTS
2 CONTENTS Page GENERAL......................................................... 2 UNIT INSPECTION ........................................... 2 INSTALLATION ............................................. 2-5 LOCATE UNIT .............................................. 2 LEVEL ............................
Page 3 - FIGURE 1 - MIRACOOLTM BOTTLE COOLER UNIT COMPONENTS (MC2000H SHOWN)
3 FIGURE 1 - MIRACOOL™ BOTTLE COOLER UNIT COMPONENTS (MC2000H SHOWN)
Page 4 - LEVEL UNIT; TO GAIN ACCESS TO LEVELING; FIGURE 2 – REMOVE FRONT GRILLE; TO LEVEL UNIT; DANGER
4 LEVEL UNIT To provide adequate condensate drainage and proper door alignment and operation of unit, the unit cabinet must be level. Lev eling feet are factory installed. Remove the front grille to gain access to front and back feet. TO GAIN ACCESS TO LEVELING FEET U DANGER Before servicing unit, d...
Page 5 - INSTALL SHELVES; WARNING; TO INSTALL SHELVES; FIGURE 4 – SHELF CLIP INSTALLATION; CONDENSATE DISPOSAL
5 INSTALL SHELVES Product shelves and a bag containing shelf support clips are packed inside the unit. Refer to Table 1 to verify quantity of shelves and shelf supporting clips. Bottom shelf must be placed on interior floor and should be inserted into the two retainer clips provided at the rear corn...
Page 6 - PRELIMINARY CHECKS; BI-PIN FLUORESCENT LAMP; CAUTION; ELECTRICAL SUPPLY AND
6 START-UP PRELIMINARY CHECKS BI-PIN FLUORESCENT LAMP INSTALLATION / VERIFICATION Before applying power to the unit, verify that all lamps hav e been properly installed and are fully engaged in the lamp holders. There are 2 lamps in the signboard and 2 inside the cooler. U CAUTION Improperly install...
Page 7 - TABLE 2 – UNIT DATA; POWER SUPPLY
7 TABLE 2 – UNIT DATA UNIT MC2000H / MC2000S Voltage (V) Nominal 115 Range 105-125 Frequency (Hz) 60 Total Amps 11.3 Refrigerant Type R-134A Charge Amount (oz) 19.4 Design Pressure (psig) High Side 220 Low Side 88 INITIAL START-UP POWER SUPPLY Connect unit to power supply. Check to verify that the c...
Page 8 - COMPONENTS; CONDENSER
8 REFRIGERATION SYSTEM SERVICE COMPONENTS The Carrier Miracool™ refrigeration system consists of a hermetically sealed compressor and finned evaporator and condenser coils. CONDENSER The condenser has wide finned spaces, which allow more air passage with less dirt or dust accumulation. The condenser...
Page 9 - EVACUATION
9 EVAPORATOR COMPARTMENT SERVICING U DANGER Before servicing unit, disconnect electrical service. Failure to disconnect electrical service could result in electrical shock and cause personal injury or death. 1. After disconnecting the unit from the power supply, remove the grille retaining screw loc...
Page 10 - TABLE 3 – REFRIGERATION SYSTEM SERVICE AND ANALYSIS CHART; REFRIGERATION SYSTEM; MALFUNCTION
10 TABLE 3 – REFRIGERATION SYSTEM SERVICE AND ANALYSIS CHART REFRIGERATION SYSTEM MALFUNCTION POSSIBLE CAUSE SOLUTION 1. Line cord not plugged in. 1. Plug in the cord. 2. Fuse removed or blown. 2. Replace fuse. 3. Overload protector tripped. 3. Ref er to electrical section. 4. T emp control stuck in...
Page 11 - FIGURE 12 – WIRING DIAGRAM
Page 12 - MAINTENANCE
12 MAINTENANCE LAMP REPLACEMENT U DANGER Before servicing unit, disconnect electrical service. Failure to disconnect electrical service could result in electrical shock and cause personal injury or death. Remove lamp by rotating lamp 90 degrees to align lamp pins with holder slots. Refer to Bi-Pin F...
Page 13 - TABLE 4 –METHODS FOR CLEANING STAINLESS STEEL
13 TABLE 4 –METHODS FOR CLEANING STAINLESS STEEL TASK CLEANING AGENT* METHOD OF APPLICATION EFFECT ON FINISH Routine Cleaning Soap, ammonia or detergent and water Sponge with cloth, then rinse with clear water and wipe dry. Satisf actory f or use on all finishes. Revere W are, Goddard’s, Twinkle or ...