Summary

Page 2 - INSTALLATION; Check Equipment and Job Site; Unpack Unit; Install on a Solid, Level Mounting Pad; Operating Ambient; WARNING

2 located on control box cover and/or in the Check Charge section ofthis instruction. IMPORTANT : Maximum liquid--line size is 3/8--in. OD for all residential applications including long line. IMPORTANT : Always install the factory--supplied liquid--line filter drier. Obtain replacement filter drier...

Page 3 - Outdoor Unit Connected to Factory Approved Indoor; O u td o o r u n it co n tain s co rrect sy stem refrig eran t ch arg e fo r; Table 1 – Accessory Usage

3 There are no buried--line applications greater than 36 in. (914.4mm).If refrigerant tubes or indoor coil are exposed to atmosphere, they must be evacuated to 500 microns to eliminate contamination and moisture in the system. Outdoor Unit Connected to Factory Approved Indoor Unit O u td o o r u n i...

Page 4 - MINUTES; LEAK IN; MI; Make Electrical Connections

4 Install Liquid Line Filter Drier Indoor CAUTION ! UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation.Installation of filter drier in liquid line is required. Filter drier must be wrapped in a heat--sinking material such as a wet cloth while brazi...