Page 2 - —Installation
Step 1—Inspect Package and Check Equipment Inspect contents of packaged humidifier. File claim with shippingcompany prior to installation if shipment is damaged or incom-plete.The package should contain: 1. Humidifier and media assembly 2. Humidistat 3. Template 4. Owner’s Manual 5. Warranty Certifi...
Page 3 - Fig. 4—Installation of Humidistat
Step 7—Make Water Connection If garden hose is not used for water supply: 1. Mount saddle valve on water line according to instructions supplied with valve. 2. Run 1/4-in. diameter (water line grade) tubing from saddle valve to adapter on solenoid valve and tighten compressionfittings. IMPORTANT: If...
Page 5 - VERTICAL; Fig. 8—Reversing Door Access; DRAIN OUTLET
7. Saddle valve assembly with adapter 8. Four sheet metal screws 9. Foam tape 10. Noise suppressor (use for water pressure over 60 psi) 11. Worm clamp for field-supplied drain tube 12. Humidifier maintenance instruction sticker 13. Carrier logo label Step 2— Select Location (See Fig. 7.) Humidifier ...
Page 6 - Fig. 10—Top Mounting of Water Solenoid Valve
Step 6—Mount Solenoid Valve The water solenoid valve should be mounted on top of humidifierenclosure. 1. To mount solenoid on top, see Fig. 10. a. Firmly press valve into the top inlet hole on enclosure. Seat valve flush against inlet hole. 2. If alternate mounting of solenoid is required, see Fig. ...
Page 7 - Fig. 12—Installation of
Step 1—Inspect Package and Check Equipment Inspect the contents of packaged humidifier. File claim withshipping company prior to installation if shipment is damaged orincomplete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3. Template 4. 6-in. damper 5. Owner’s Manual ...
Page 9 - Water Saver Humidifier
Step 3—Prepare Plenum Opening (See Fig. 2.) 1. Use template for marking humidifier opening. 2. Tape in place on plenum making sure template is level. IMPORTANT: For humidifier to operate properly it must be level and mounted on a vertical surface. 3. Drill four 1/8-in. holes in plenum. 4. Cut openin...
Page 10 - Fig.17—Humidistat Installation for; KNOB
compression fittings. Plastic compression nut supplied withfloat valve should not be torqued greater than 25 in.-lb. Forcopper tubing installations: copper tubing may be connected tofloat valve by using a field-supplied 1/4 to 1/4 in. straight-through compression union. Run copper tubing to 1 side o...
Page 11 - Fig. 20—Alternate Location Duct Mount Installation
5. Mount case horizontally over wires directly to wall using 2 long screws provided. 6. Replace faceplate and knob. Step 2—Duct Mounting (Low Voltage) 1. Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in.upstream of elbow so ele...
Page 12 - Fig. 21—Humidistat Installation Schematic; CASE; MAKE OPENING IN DUCT; Recommended Humidistat Setting; OUTSIDE
Step 5—Operation When relative humidity falls to humidistat set point, the humidistatswitch makes contact and starts humidifier. In some central unithumidifier systems, furnace fan must be operating before humidi-fier will start. An increase in relative humidity above set point willstop humidifier. ...