Page 2 - HEAT EXCHANGERS; CONTROL CENTER
2 exchanger ensures that all available heat is properly transferred to the airstream and throughout the home. Using the exclusive flow-through design, the secondary heat exchanger reduces the pressure drop in the furnace which leads to lower electrical usage, an important part of this unit’s efficie...
Page 3 - and listed accessory conversion kit.
3 NOTES: 1. The 58MXA Furnaces are for use with natural gas, but can be field converted for propane gas with a factory-authorized and listed accessory conversion kit. 2. Component location and configuration may be different than shown above. A98292 12 11 6 8 10 9 7 6 45 2 1 13 14 18 3 15 16 17 19 Bu...
Page 4 - Model number nomenclature; Series; ama
4 Model number nomenclature 58MXA 040 Deluxe 4-Way Multipoise Fixed-CapacityDirect-Vent Condensing Gas Furnace Input Capacity040 — 40,000 Btuh 100 — 100,000 Btuh 060 — 60,000 Btuh 120 — 120,000 Btuh 080 — 80,000 Btuh 140 — 138,000 Btuh 140 08 Cooling Airflow(Nominal 400 CFM per12,000 Btuh Cooling)08...
Page 5 - Physical data
5 Physical data * Capacity in accordance with U.S. Government DOE test procedures. † Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Can- ada, derate the unit 5% for elevations 2000 to 4500 ft above sea l...
Page 7 - Electronic air cleaner is shown.
7 ® A93086 CONCENTRIC VENT A concentric vent kit allows vent and combustion-air pipes toterminate through a single exitin a roof or side wall. One pipe runs inside the otherallowing venting through the inner pipe and combustion air to be drawn in through the outer pipe. A88202 DOWNFLOW SUBBASE One b...
Page 8 - Dimensions
8 17 5 ⁄ 16 " 24 1 ⁄ 2 " 27 9 ⁄ 16 " TYP 27 5 ⁄ 8 " 29 11 ⁄ 16 " TYP 30 13 ⁄ 16 " 32 5 ⁄ 8 " TYP 33 1 ⁄ 4 " TYP CONDENSATE DRAIN TRAP LOCATION (ALTERNATE UPFLOW) 7 ⁄ 8 -IN. DIA ACCESSORY POWER ENTRY 7 ⁄ 8 -IN. DIA POWER CONN CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW &a...
Page 9 - Assembled
9 DOWNFLOW SUBBASE — DIMENSIONS (In.) * The plenum should be constructed 1/4 in. smaller in width and depth than the plenum dimensions shown above. FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING* FLOOR OPENING HOLE NO. FOR WIDTH ADJUSTMENT A B C D 17-1/2 Furnace with or without ...
Page 10 - CONDENSATE TRAP; MEDIA FILTER CABINET
10 CONDENSATE TRAP 1 ⁄ 2 OD INDUCER HOUSINGDRAIN CONNECTION 1 ⁄ 4 OD COLLECTOR BOX TOTRAP RELIEF PORT 5 ⁄ 8 OD COLLECTOR BOXDRAIN CONNECTION 1 ⁄ 2 -IN. PVC OR CPVC SCREW HOLE FORUPFLOW OR DOWN-FLOW APPLICATIONS(OPTIONAL) 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION (OPTIONAL) WIRE TIEGUIDES...
Page 11 - Clearance to combustibles; MINIMUM INCHES CLEARANCE
11 Clearance to combustibles A97609 324999-201 TOP REV. B MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION * Mimimum front clearance for service 30 inches (762mm). 140 size furnaces require 1 inch back clearance to combustible materials. For installation on combustible floors only when installed...
Page 12 - Performance data; EFFICIENCY
12 Performance data PSC—Permanent Split Capacitor EFFICIENCY * Capacity and AFUE in accordance with U.S. Government DOE test procedures effective November 10, 1997. ICS—Isolated Combustion System UNIT SIZE 040-08 040-12 060-08 060-12 060-16 080-12 080-16 080-20 100-16 100-20 120-20 140-20 DIRECT-DRI...
Page 14 - Combustion-air and vent piping
14 Combustion-air and vent piping MAXIMUM ALLOWABLE PIPE LENGTH (FT) See notes on pg. 15. ALTITUDE ABOVE SEA LEVEL (FT) UNIT SIZE TERMINATION TYPE PIPE DIA (IN.)* NUMBER OF 90° ELBOWS 1 2 3 4 5 6 0 to 2000 040-08040-12 2 Pipe or 2-In. Concentric 1 5 NA NA NA NA NA 1-1/2 70 70 65 60 60 55 2 70 70 70 ...
Page 15 - MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued
15 MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued * Disk usage—Unless otherwise specified, use perforated disk assembly (factory-supplied in loose parts bag). If 1 disk is stated, separate 2 halves of perforated disk assembly and use shouldered disk half. When using shouldered disk half, install scree...
Page 16 - IN WINTER DESIGN TEMPERATURE AMBIENT
16 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT * * Pipe length (ft) specified for maximum vent pipe lengths located in unconditioned spaces. Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as...
Page 18 - Typical installations; Basement — Upflow Application; Closet — Downflow Application; ELECTRONIC
18 Typical installations Basement — Upflow Application A93063 COMBUSTIONAIR PIPE A/C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS-FIREDWATER HEATER ELECTRONICAIR CLEANER AIRFLOW Closet — Downflow Application A93064 ELECTRONIC AIR CLEANER HUMIDIFIER A/C COIL VENT COMBUSTIONAIR OUTDOORUNIT AIRFLOW