Page 2 - MODEL NUMBER NOMENCLATURE; Product Type; Climate Map for Energy and Heat Recovery Ventilators; ER

2 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 E R V C C S H B 1 1 0 0 Product Type Maximum Capacity ERV -- Energy Recovery Ventilator 100 -- 100 CFM HRV -- Heat Recovery Ventilator Electrical Supply Brand 1 -- 115 Volts CC -- Carrier Style SHB -- Small HorizontalSVB -- Small Vertical Climat...

Page 3 - VENTILATOR ACCESSORY NUMBER NOMENCLATURE; Control features

3 VENTILATOR ACCESSORY NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 K V B C N 0 1 0 1 C B S Product Control Description KV -- Ventilator Accessory Kit CBS -- Carrier Basic ControlCLC -- Carrier Latent Control Series CLT -- Carrier OneTouch Control A -- Original Series CST -- Carrier Standard Contr...

Page 4 - Fresh air to building; Key to Unit Port Locations

4 MODEL 23 _ F TO --- 17 _ F ( --- 5 _ C TO --- 27 _ C) BELOW --- 17 _ F ( --- 27 _ C) DEFROST* EXCHANGE { DEFROST* EXCHANGE { ERVCCSHB HRVCCSHB 8 Minutes 25 Minutes 10 Minutes 22 Minutes ERVCCSVB HRVCCSVB 8 Minutes 25 Minutes 10 Minutes 22 Minutes * All defrost times are in the standard mode (as sh...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14

Summary

Page 2 - Inspect Equipment; should be located in a conditioned space; COMPONENT DESCRIPTION; ER

2 INTRODUCTION The Energy/Heat Recovery Ventilator (ERV/HRV) is used toexchange indoor stale air with outside fresh air. The unit is equipped with a special energy/heat recovery core which transfersboth sensible and/or latent heat between the fresh incoming air and stale exhaust air. The cross--flow...

Page 3 - UNIT INSTALLATION; UNIT DAMAGE HAZARD; CAUTION; Mount Unit; CARBON MONOXIDE POISONING HAZARD; WARNING; NOTE

3 UNIT INSTALLATION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation.Do not install ERV/HRV in a corrosive or contaminated atmosphere. CAUTION ! Mount Unit The ERV/HRV can be suspended from floor joists using chains and 4 springs. Attach metal ha...

Page 4 - PROPERTY DAMAGE HAZARD; Insulated flexible duct is required on both fresh--air inlet and; IMPORTANT; WALL CONTROL; Table 1 – Basic Control

4 Connect Ducts to ERV/HRV PROPERTY DAMAGE HAZARD Failure to follow this caution may result in minor property damage from sweating duct or loss of unit efficiency and capacity.If ERV/HRV duct work is installed in an unconditioned space, insulated flexible duct is required. CAUTION ! Insulated flexib...