Page 2 - Table Of Contents; CAUTION; Commercial Systems & Services Carrier Corporation 3/00
Table Of Contents FRONT PANELDISPLAYBASIC OPERATIONADVANCED SETUPABOUT ADVANCED OPERATIONWARRANTY Page 1 CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS. P/N 50QE900-NPWS 2 3 57 1015 Commercial...
Page 3 - Front Panel; Liquid Crystal Display; with Thermoglow; Mode Button
Front Panel Page 2 Liquid Crystal Display with Thermoglow Up/Down Buttons Mode Button Fan Button Heat or Cool Indicator Heat = Red, Cool = Green 1 2 3 4 5 2 3 4 5 1 88 OFFON AUTO Setup o 88 88 Carrier
Page 4 - - indicates the air conditioning mode.; AUTO; - indicates the system will automatically; OFF; - indicates the entire system is turned off.; Display
88 OFFON AUTO Setup o 88 88 1 2 3 Mode Indicators Selects the operation mode of the equipment. - indicates the heat mode. - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies. OFF - indicates the entire...
Page 5 - Fan On; is not lit - indicates the fan will
4 5 6 Setup Indication Indicates the thermostat is in the Advanced Setup mode. Page 7. Fan Operation Indication - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when necessary to heat or to cool. Page 6. Locked Indication appears after the ...
Page 6 - Select Mode; Basic Operation
The HEAT setting indicates the temperature the room has toreach before the furnace will turn on to heat the room. The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room. OFF indicates both heating and air conditioning systems are tur...
Page 7 - Select Desired Temperature; Fan; Off
buttons. In any mode, adjust the desired Set Temperature with Pressing the up/down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously.Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Select Desired Temperature ...
Page 8 - Advanced Setup; Cy
Advanced Setup Page 7 Press Press Press Continued Press the Mode button.While holding the Mode,press the Fan button for 7 seconds to enter Setupscreens. NOTE: Each step # is located at the top right corner of the display for easy reference. FAN MODE MODE MODE MODE Adjust the deadbandfrom 1 - 6 degre...
Page 9 - L I
Advanced Setup Page 8 Press MODE Select the display back-light always On , or Off after 8 seconds. On Off Press MODE Setup L I 4 ON Continued Select thermostatoperation in degrees F ahrenheit or C entigrade. C F Setup F 5
Page 10 - Advanced Setup Table
Advanced Setup Page 9 Step # Description Range Factory Default 1 2 3 4 5 6 Deadband or Temperature swing 1 - 6 2Forced minimum difference heat/cool 0 - 6 2Cycles per hour d, d1, 2 - 6 6Thermoglow backlight Off / On OnFahrenheit or Centigrade F / C FReversing Valve polarity O / B O Advanced Setup Tab...
Page 11 - About Advanced Features & Operation; and; the setpoint; step
About Advanced Features & Operation Page 10 2 STAGE OPERATION - The 2nd Stage of heat or cool is turned on when ( 1 ) the 1st Stage has been on for a minimum of two minutes, and ( 2 ) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 deg...
Page 12 - To turn on Emergency; eh
About Advanced Features & Operation Page 11 EMERGENCY HEAT - the Fan button press The Cool setpoint display During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat, when there is a demand for heat, locking out the 1st stage compressor. Exiting Emergency Heat is the sa...
Page 13 - icon will appear on the; unlock; Locked; icon will
About Advanced Features & Operation Page 12 KEYPAD LOCK - To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The ...
Page 14 - Both; will not
About Advanced Features & Operation Page 13 DUAL SETPOINT BEHAVIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, the thermostat allow the Heat ...
Page 15 - Fd; appears. This resets all factory settings.; To calibrate; press the Mode button once more.
About Advanced Features & Operation Page 14 FACTORY DEFAULTS - If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Down button for 2 sec. All icons will appear. Press and hold in...
Page 16 - Warranty
Warranty Page 15 P/N 88-256 One-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or notactual use begins on that date, that the product does not meet this warranty, a new orrem...