Page 2 - Trademarks; 01 Explorer Boulevard
Trademarks NetVanta 4660/5660 Series 2 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of this manual are cur...
Page 3 - Conventions; Notes provide additional useful information.
NetVanta 4660/5660 Series Conventions 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 3 Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or en...
Page 4 - Safety Instructions; risk of shock from lightning.; Save These Important Safety Instructions; NetVanta Safety and Regulatory Information
Safety Instructions NetVanta 4660/5660 Series 4 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water,...
Page 5 - FCC-Required Information; leased line facilities:
NetVanta 4660/5660 Series FCC-Required Information 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 5 FCC-Required Information FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of Federal Communications Commission (FCC) rules and ...
Page 6 - FCC Radio Frequency Interference Statement
FCC Radio Frequency Interference Statement NetVanta 4660/5660 Series 6 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These...
Page 7 - Toll Fraud Liability; . You can obtain the complete corresponding source code of such; Service and Warranty; Support
NetVanta 4660/5660 Series Toll Fraud Liability 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 7 Toll Fraud Liability Be advised that certain security risks are inherent in the use of any telecommunications or networking equipment, including but not limited to, toll fraud, Denial of Service (DoS) atta...
Page 9 - Table of Contents
617004660F1-34A Copyright © 2014 ADTRAN, Inc. 9 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 11 - List of Figures
617004660F1-34A Copyright © 2014 ADTRAN, Inc. 11 List of Figures Figure 1. NetVanta 4660/5660 Series Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 2. NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A . . . . . . . . . . . . . . . . . . . . . ...
Page 13 - List of Tables
617004660F1-34A Copyright © 2014 ADTRAN, Inc. 13 List of Tables Table 1. Front Panel Status LED Behaviors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table 2. NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A LED Behaviors . . . . . . . . . 24 Ta...
Page 15 - INTRODUCTION; ADTRAN Support Community
617004660F1-34A Copyright © 2014 ADTRAN, Inc. 15 1. INTRODUCTION This hardware installation guide describes the NetVanta 4660/5660 Series units’ physical characteristics, lists their features and specifications, introduces basic functionality, and provides installation instructions in the following ...
Page 16 - Physical Description; PHYSICAL DESCRIPTION; Network Modules Supported; Shipping Contents
Physical Description NetVanta 4660/5660 Series 16 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A 2. PHYSICAL DESCRIPTION The NetVanta 4660 is an integrated Layer 2 and Layer 3 carrier Ethernet services router providing a universal edge device supporting any mix of Layer 3 IP Virtual Private Network (...
Page 17 - NetVanta 4660/5660 Series International Shipping Contents
NetVanta 4660/5660 Series Physical Description 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 17 NetVanta 4660/5660 Series Domestic Shipping Contents Domestic shipments of the NetVanta 4660/5660 Series include the following items: • NetVanta 4660/5660 base unit • Set of two 19-inch rack mounting brac...
Page 18 - LED Descriptions
Physical Description NetVanta 4660/5660 Series 18 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A The GIG 0/2 through GIG 0/5 ports consist of one RJ-45 and one SFP slot for connectivity over fiber. (Use either the RJ-45 connector or the SFP slot. The fiber slot has precedence.) See Table A-3 on page ...
Page 19 - Features and Specifications; FEATURES AND SPECIFICATIONS; Physical Interfaces; Ethernet
NetVanta 4660/5660 Series Features and Specifications 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 19 3. FEATURES AND SPECIFICATIONS NetVanta 4660 • Universal edge device supporting modular Layer 2/3 Carrier Ethernet services with Gigabit combo interfaces NetVanta 5660 • Same functionality as the N...
Page 20 - Security
Features and Specifications NetVanta 4660/5660 Series 20 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A Management and Utilities • AOS command line interface (CLI) • ADTRAN n-Command ® Managed Service Platform (MSP) • Simple Network Management Protocol version 3 (SNMPv3) • SYSLOG logging • Telnet, cr...
Page 21 - DSL Features; Ethernet Services Support; Fault and Performance Management
NetVanta 4660/5660 Series Features and Specifications 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 21 • Encryption: DES, 3DES, and AES • Authentication Mechanisms: – XAUTH Secure ID – X.509 digital certificates – DSS Signatures – Preshared keys DSL Features • Variable rate bonding for the SHDSL loo...
Page 22 - Environment; Operating Temperature with AC power supply: 0°C to 40°C (32°F to 104°F); Physical and Input Power; Input Voltage: 48 VDC; Agency Approvals; CE Mark
Features and Specifications NetVanta 4660/5660 Series 22 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A Environment • Operating Temperature without AC power supply: -25°C to 70°C (-13°F to 158°F) • Operating Temperature with AC power supply: 0°C to 40°C (32°F to 104°F) • Storage Temperature: -40°C to...
Page 23 - Option Modules; OPTION MODULES; Appendix A
NetVanta 4660/5660 Series Option Modules 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 23 4. OPTION MODULES The NetVanta 4660/5660 Series supports several option modules designed to meet a variety of networking requirements. The option modules include plug-in network modules. Network modules are car...
Page 24 - Network Modules; Figure 2; LED; Electromagnetic
Option Modules NetVanta 4660/5660 Series 24 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A Network Modules NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A (P/N 17406368F1) The NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A (shown in Figure 2 ) provides a WAN-SHDSL EFM interface. Se...
Page 25 - Figure 3
NetVanta 4660/5660 Series Option Modules 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 25 NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex B (P/N 17406368F3) The NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex B (shown in Figure 3 ) provides a WAN-SHDSL EFM interface. See Table A-5 on p...
Page 26 - Figure 4
Option Modules NetVanta 4660/5660 Series 26 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex A (P/N 17806368F1) The NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex A (shown in Figure 4 ) provides a WAN-SHDSL EFM interface. See Table A-6 on...
Page 27 - Figure 5
NetVanta 4660/5660 Series Option Modules 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 27 NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex B (P/N 17806368F3) The NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex B (shown in Figure 5 ) provides a WAN-SHDSL EFM interface. See Table A-6 on...
Page 28 - Figure 6
Option Modules NetVanta 4660/5660 Series 28 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex A (P/N 17406369F1) The NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex A (shown in Figure 6 ) provides a WAN-VDSL interface. See Table A-8 on page 3...
Page 29 - Figure 7
NetVanta 4660/5660 Series Option Modules 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 29 NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex B (P/N 17406369F3) The NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex B (shown in Figure 7 ) provides a WAN-VDSL interface. See Table A-8 on page 3...
Page 30 - Unit Installation; UNIT INSTALLATION; Tools Required on page 30; Tools Required; Ethernet cables
Unit Installation NetVanta 4660/5660 Series 30 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A 5. UNIT INSTALLATION The instructions and guidelines provided in this section cover hardware installation topics, such as mounting options, supplying power to the unit, and installing option cards. These ins...
Page 31 - Mounting Options; Rack Mounting the NetVanta; Instructions for Rack Mounting the NetVanta; Apply power to the unit (refer to
NetVanta 4660/5660 Series Unit Installation 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 31 Mounting Options The unit may be installed in rackmount, wallmount, or tabletop configurations. The following sections provide step-by-step instructions for rack mounting and wall mounting. Rack Mounting the...
Page 32 - Wall Mounting the NetVanta; Figure 8. Wallmount Installation; Figure 8 on
Unit Installation NetVanta 4660/5660 Series 32 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A Wall Mounting the NetVanta By following these instructions exactly, the NetVanta can be safely mounted on the wall. Figure 8. Wallmount Installation • To avoid damaging the unit, use only the screws included...
Page 33 - Connecting Ground to the Unit; Use a reliably grounded 48VDC SELV source.; Instructions for Powering the NetVanta 4660/5660 Series; on the
NetVanta 4660/5660 Series Unit Installation 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 33 Connecting Ground to the Unit Connect the supplemental ground before connecting the power and signal connectors. Connect the unit to a reliable ground point using a minimum 18 AWG (0.75 mm sq.) ground wire a...
Page 34 - Figure 9. Network Module Installation; ADTRAN’s; Instructions for Installing the Network Modules; Remove power from the unit.
Unit Installation NetVanta 4660/5660 Series 34 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A Figure 9. Network Module Installation Your NetVanta unit is now ready to be configured and connected to the network. For information on configuration for a specific application, refer to the configuration gu...
Page 35 - CONNECTOR PIN DEFINITIONS; Base Unit Pinouts
617004660F1-34A Copyright © 2014 ADTRAN, Inc. 35 APPENDIX A. CONNECTOR PIN DEFINITIONS The following tables provide the pin assignments for the base unit and network interface modules (NIMs). Base Unit Pinouts Table A-1. CONSOLE Port Pinouts Pin Name Description 1 DCD Data Carrier Detect (output) 2 ...
Page 37 - Network Module Pinouts
NetVanta 4660/5660 Series Appendix A 617004660F1-34A Copyright © 2014 ADTRAN, Inc. 37 Network Module Pinouts Table A-5. Quad SHDSL EFM Pinouts Ports 1 and 2 Ports 3 and 4 Pin Name Description Pin Name Description 1 T02 Loop 2 - Tip 1 T04 Loop 4 - Tip 2 R02 Loop 2 - Ring 2 R04 Loop 4 - Ring 3 — Unuse...