Page 2 - 9SC5 FEATURES AND BENEFITS
2 SAP ORDERING NO. CASING DIMENSIONS (IN.) RATED HEATING OUTPUT† HEATING AIRFLOW COOLING CFM @ 0.5 ESP (in WC) MOTOR HP-SPEED APPROX SHIP WEIGHT (LB) H D W (BTUH) AFUE CFM‡ Heating ESP (in. WC) 59SC5A040S14--10 35 29.5 14.2 39,000 95.5% 820 0.10 625-905 1/2 - 4 123 59SC5A060S14--10 35 29.5 14.2 58,0...
Page 3 - SPECIFICATIONS
3 SPECIFICATIONS Heating Capacity and Efficiency 040-10 060-10 060-14 080-16 080-20 100-14 100-20 120-20 140-20 Input High Heat (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000 Output High Heat (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000 Efficienc...
Page 4 - MODEL NUMBER NOMENCLATURE; FURNACE COMPONENTS
4 MODEL NUMBER NOMENCLATURE 59 S C 5 A 040 S 14 -- -- 10 S - Single StageT - Two StageM - Modulating C - ComfortP - PerformanceN - Infinity 0 --- 90 AFUE3 --- 93 AFUE5 --- 95 AFUE6 --- 96 AFUE7 --- 97 AFUE S - StandardE - Energy EfficientV - Variable Speed 14 - 14.2”17 - 17.5”21 - 21.0”24 - 24.5” 08...
Page 5 - ACCESSORIES
5 ACCESSORIES Part Number Used With Notes KGADC0101BVC All 1 KGAVT0701CVT See Venting Tables 1 KGAVT0801CVT See Venting Tables 1 KGAVT0101BRA See Venting Tables 1, 2 KGAVT0201BRA See Venting Tables 1, 2 Part Number Used With Notes KGAHT0201CFP All 7 KGAHT0101CFP All - KGAAD0110PVC All - KGACK0101HCK...
Page 8 - Venting System Length Calculations; FOR EACH; long radius elbows and a concentric vent kit.; EACH
8 MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M) Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M) Pipe Diameter (in): 1-1/2 2 2-1/2 3 4 Mitered 90º Elbow 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) Medium Radius 90º Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Long Radius 90º Elbow 3 (0.9...
Page 11 - RETURN AIR TEMPERATURE; C) db or intermittent operation down to 55; SUPPLY AIR; MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS; ELBOW
11 RETURN AIR TEMPERATURE This furnace is designed for continuous return--air minimum temperature of 60 _ F (15 _ C) db or intermittent operation down to 55 _ F (13 _ C) db such as when used with a night setback thermometer. Return--air temperature must not exceed 80 _ F (27 _ C) db. Failure to foll...
Page 12 - DOWNFLOW SUBBASE; Assembled; FURNACE; Concentric Vent Kit; installed in downflow applications.
12 DOWNFLOW SUBBASE LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 / 4-IN. TYP PLENUMOPENING FACTORY-SUPPLIED FIELD-INSTALLED INSULATION Assembled Disassembled A97427 A88207 DIMENSIONS (IN. / MM) FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING* FLOOR OPENING HOLE NO. FOR W...
Page 13 - MEDIA FILTER CABINET; B Opening; TYPICAL WIRING SCHEMATIC
13 MEDIA FILTER CABINET Media Filter Cabinet A B 16" (406mm) 20" (508mm)24" (610mm) 17" (432mm) Furnace Side Centerline Screw Slots 23-3/4” 23-3/8” 23-5/8" 5 3 4 Duct Side Opening Opening with Flanges Bent 24-1/4” 25-5/8" B Opening A " (600mm) (594mm) (603mm) (146mm) (651...
Page 14 - DIMENSIONAL DRAWING
Page 15 - GUIDE SPECIFICATIONS; General
15 GUIDE SPECIFICATIONS General System Description Furnish a ______________________ 4--way multipoise gas--fired condensing furnace for use with natural gas or propane (factory--authorized conversion kit required for propane); furnish cold air return plenum; furnish external media cabinet for use wi...