Page 2 - FEATURES AND BENEFITS
2 SAP ORDERING NO. CASING DIMENSIONS (IN.) RATED HEATING OUTPUT† HEATING AIRFLOW COOLING CFM @ 0.5 ESP (in. WC) MOTOR HP-SPEED APPROX SHIP WEIGHT (LB) H D W (BTUH) AFUE CFM‡ Heating ESP (in. WC) 59SC2A040S14--10 35 29.5 14.2 39,000 92.1% 820 0.10 625-905 1/2 - 4 123 59SC2A060S14--10 35 29.5 14.2 58,...
Page 3 - SPECIFICATIONS; Heating Capacity and Efficiency; * See Accessory List for part numbers available.
3 SPECIFICATIONS Heating Capacity and Efficiency 040-10 060-10 060-14 080-16 080-20 100-14 100-20 120-20 Input High Heat (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 Output High Heat (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 Efficiency AFUE % (ICS) 92.1 92....
Page 4 - MODEL NUMBER NOMENCLATURE; Example of Model Number; FURNACE COMPONENTS
4 MODEL NUMBER NOMENCLATURE 59 T N 6 A 060 V 17 -- -- 14 S - Single StageT - Two StageM - Modulating C - ComfortP - PerformanceN - Infinity S - StandardE - Energy EfficientV - Variable Speed 14 - 14.2”17 - 17.5”21 - 21.0”24 - 24.5” 08 - 800 CFM10 - 1000 CFM12 - 1200 CFM14 - 1400 CFM16 - 1600 CFM18 -...
Page 5 - ACCESSORIES
5 ACCESSORIES DESCRIPTION PART NUMBER 040 --- 10 060 --- 10 060 --- 14 080 --- 16 080 --- 20 100-14 100-20 120-20 Venting Accessories Vent Kit - Through the Cabinet KGADC0101BVC D D D D D D D D Vent Terminal - Concentric - 2” (51 mm) KGAVT0701CVT See Venting Tables Vent Terminal - Concentric - 3” (7...
Page 8 - Venting System Length Calculations; The Total Equivalent Vent Length (TEVL) for; Example 1; long radius elbows and a factory accessory concentric vent; Example 2
8 Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 2.Standard vent terminations or factory accessory concentric vent term...
Page 11 - RETURN AIR TEMPERATURE; C) db or intermittent operation down to 55; SUPPLY AIR; MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS; ELBOW
11 RETURN AIR TEMPERATURE This furnace is designed for continuous return--air minimum temperature of 60 _ F (15 _ C) db or intermittent operation down to 55 _ F (13 _ C) db such as when used with a night setback thermometer. Return--air temperature must not exceed 80 _ F (27 _ C) db. Failure to foll...
Page 12 - DOWNFLOW SUBBASE; Assembled; FURNACE; Concentric Vent Kit; installed in downflow applications.
12 DOWNFLOW SUBBASE LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 / 4-IN. TYP PLENUMOPENING FACTORY-SUPPLIED FIELD-INSTALLED INSULATION Assembled Disassembled A97427 A88207 DIMENSIONS (IN. / MM) FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING* FLOOR OPENING HOLE NO. FOR W...
Page 13 - MEDIA FILTER CABINET; B Opening; TYPICAL WIRING SCHEMATIC
13 MEDIA FILTER CABINET Media Filter Cabinet A B 16" (406mm) 20" (508mm)24" (610mm) 17" (432mm) Furnace Side Centerline Screw Slots 23-3/4” 23-3/8” 23-5/8" 5 3 4 Duct Side Opening Opening with Flanges Bent 24-1/4” 25-5/8" B Opening A " (600mm) (594mm) (603mm) (146mm) (651...
Page 14 - DIMENSIONAL DRAWING; Vent and Combustion air pipes through blower compartment must
14 DIMENSIONAL DRAWING 6 15/16 [176.1] 3 [76.2] 3 [76.2] 6 11/16 [170.1] 23 5/16 [592.9] 25 1/8 [638.7] 26 3/8 [670.0] 26 11/16 [678.1] 21 [534.0] 26 5/16 [668.8] 17 5/16 [439.2] 16 9/16 [420.9] 20 1/4 [513.9] 25 3/16 [639.1] 28 3/16 [715.9] 28 5/8 [726.4] 32 5/8 [829.5] 28 3/4 [730.5] 26 3/8 [669.9...
Page 15 - GUIDE SPECIFICATIONS; General
15 GUIDE SPECIFICATIONS General System Description Furnish a ______________________ 4--way multipoise gas--fired condensing furnace for use with natural gas or propane (factory--authorized conversion kit required for propane). Quality Assurance Unit will be designed, tested and constructed to the cu...