Page 2 - A WARNING; maintenance, or use can cause carbon monoxide poison; FURNACE
1 5. ^ r' / 8 THERMOSTAT CONN — -?>• o : a KNOCKOUT AUX GAS INLET Table 2—Dimensions (In Inches) Size A D E Vent 050-BA 14^6 12"/,e 12”/,6 4 075-AA 17^2 15^ 16 4 075-BA M 'k 15% 16 4 100-AA M 'b 15% 16 5 100-BA 17Ya 15% 16 5 125-AA 21 19% 19Ya 5 125-BA 21 19% 19% 5 150-BA 2A 'k 22% e 23 6 AIR...
Page 3 - Base Installed on a Combustible Floor; A CAUTION; SUPPLY-AIR PLENUM INSTALLATION; Fig. 6—Amp Draw Check With Ammeter
Fig. 5—Furnace, Plenum, and Base Installed on a Combustible Floor A CAUTION Do not insteill furnace in a damp, corrosive, or contaminated atmosphere. Make sure all combustion and circu lating air requirements listed in “Procedures for Natured-Draft Gas-Fired Furnaces” are adhered to, in addition t...
Page 4 - rz
FUSED DISCONNECT SW ITCH (WHEN REQ'D) ILK SWITCH TRAN CAP (WHEN USED) TO THERMOSTAT BREAKAWAY TAB REMOVED WHEN CONNECTING VENT DAMPER (SEE INSTALLATION INSTRUCT IONS)- YEL LOD- CWHEN USED) NOTES: m DOWNFLOW FURNACES ONLY I. I---- rz —I HEATING FAN RELAY CONTACT IS •-rkF* NORMALLY CLOSED UNTIL 115V A...
Page 6 - C. Blower Control Center
B. Installation on a combustible floor 1. Read Installation Instructions packaged with acces sory combustible floor base. 2. Cut eind frame hole in floor per dimensions listed in Installation Instructions packaged with combustible floor base. If this requires cutting of a floor joist, tie ends of c...
Page 7 - VIII. FILTER ARRANGEMENT; Fig. 11—Position of Fiiters; IX. STARTUP AND ADJUSTMENT; Do not; A. Adjustment of Blower Speed
3. Blower Circuit With power through the solid-state time-delay circuit on printed-circuit board PCB and heat relay HFR, blower motor MTR is energized on heating speed approximately 75 seconds after gas valve GV has been energized (or the pilot flame has been proven in the case of IID systems). 4. L...
Page 8 - Table 5—Speed Selector; B. Automatic Gas Control Valve
To change motor speed taps, remove the motor tap lead (See Table 5.) and relocate it on the desired terminal on the plugin terminal block/speed selector located on the blower. A CAUTION When adjusting the blower speed, make certain that the temperature rise across the heat exchanger does not exceed...
Page 9 - Fig. 14—White Rodgers Model 36E; B. Blower Motor Wheel; Housing and Wheei Removed; do
PILOT ADJUSTMENT- IN LE' PRES TAP OUTLETPRESSURE TAP A87230 Fig. 14—White Rodgers Model 36E A. Air Filter Each furnace accommodates two filters which can be installed above the furnace in the return-air plenum. See Fig. 11. To clean or replace the filters, proceed as follows: 1. Disconnect electrica...
Page 10 - Table 6—Trouble Analysis Chart; A W A R N I N G
Table 6—Trouble Analysis Chart A W A R N I N G To avoid possibility of fixe, explosion, electric shock, personal injury or death, turn off gas and power supply to unit before servicing (unless specific test requires gas and electric suppHes). SYMPTOM CAUSE REMEDY Furnace will not operate No 115-volt...