Carrier 50SX024-060- Manuals

Carrier 50SX024-060– User Manual, Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28

Summary

Page 2 - Table of contents; Page

2 Variable-speed ECM integrated control motors are standard on 048 and 060 units. Direct-drive, PSC condenser-fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40°F. Refrigerant system is designed to provide dependability. Liquid refrigerant strainer...

Page 3 - Model number nomenclature; COOLING CAPACITIES AND EFFICIENCIES

3 Model number nomenclature ARI* capacities COOLING CAPACITIES AND EFFICIENCIES 50SX 024 Model No. 50SX – Single Packaged ----------- Electric Cooling Nominal Cooling Capacity (Tons)024 – 2 030 – 2-1/2 036 – 3 042 – 3-1/2 048 – 4 060 – 5 UNIT 50SX NOMINAL TONS STANDARD CFM NET COOLING† CAPACITIES (B...

Page 4 - OUTDOOR SOUND: OCTAVE BAND DATA — DECIBELS; Physical data

4 OUTDOOR SOUND: OCTAVE BAND DATA — DECIBELS Physical data LEGEND ECM — Electronic Integrated Control Motor † Recommended field-supplied filters are 1 in. thick.NOTE: Standard motors are PSC Type. FREQUENCY (Hz) SOUND POWER LEVEL FOR 50SX UNIT 024 030 036 042 048 060 63 45.7 48.7 49.1 48.4 56.0 54.3...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48

Summary

Page 2 - UNIT

REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL — in. (mm)Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 (356)Duct Side of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 (51)Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . 14 (356)Bottom of...

Page 3 - Fig. 3 — Dimensions Units 50SS018-042 with Optional Base Rail

REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL — in. (mm)Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 (356)Duct Side of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 (51)Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . 14 (356)Bottom of...

Page 5 - Fig. 5 — Dimensions Units 50SS048,060 With Optional Base Rail

REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL — in. (mm)Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 (356)Duct Side of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 (51) Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . 14...