Page 2 - Dimensions & Weights of Indoor Units
2 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products 860 350 575 (1) INNOVATIVE MODERN DESIGN 1. Modern grille design fits any interior decor with space saving. 2. Meets the demanding needs of Carrier customers....
Page 3 - Technical Bulletin; -1 SUPER EFFICIENT INDOOR UNIT
3 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (2) SUPER EFFICIENT COOLING & HEATING WITH MINIMUM ELECTRICAL CONSUMPTION 2-1 SUPER EFFICIENT INDOOR UNIT Super efficient Hi Tech AMS ( Air Management Sys...
Page 4 - -2 SUPER EFFICIENT OUTDOOR UNIT; Super efficient propeller with maximum air flow
4 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products SUPER EFFICIENT COOLING & HEATING WITH MINIMUM ELECTRICAL CONSUM (Cont.) 2-2 SUPER EFFICIENT OUTDOOR UNIT Super efficient propeller with maximum air flow ...
Page 5 - (3) SUPER QUIET OPERATION WITH MINIMUM SOUND LEVELS; -1 SUPER QUIET INDOOR UNIT; Super quiet and quiet air path drawn through coil.; Super quiet motor with minimum vibrations.; Mounted in a closed compartment away from the air path.
5 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (3) SUPER QUIET OPERATION WITH MINIMUM SOUND LEVELS 3-1 SUPER QUIET INDOOR UNIT Super quiet Hi Tech AMS ( Air Management System ) with minimum air resistance ...
Page 6 - -2 SUPER QUIET OUTDOOR UNIT
6 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products SUPER QUIET OPERATION WITH MINIMUM SOUND LEVELS (Cont.) 3-2 SUPER QUIET OUTDOOR UNIT Super quiet propeller with minimum air resistance and smooth air flow • I...
Page 7 - (4) SUPER COMPLETE CONTROL FUNCTIONS FOR EFFICIENT OPERATION; -1 Innovative My Comfort Smart Wireless Remote Control; sensitive electronic components:
7 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (4) SUPER COMPLETE CONTROL FUNCTIONS FOR EFFICIENT OPERATION 4-1 Innovative My Comfort Smart Wireless Remote Control - Liquid Crystal Display (LCD) wireless r...
Page 8 - MY COMFORT WIRELESS REMOTE CONTROL; DISPLAY OF
8 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products MY COMFORT WIRELESS REMOTE CONTROL 1 ON/OFF button Push the button to start operation, push the button again to stop operation. MODE select button By pressing...
Page 10 - DISPLAY OF MY COMFORT SMART REMOTE CONTROL
10 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products DISPLAY OF MY COMFORT SMART REMOTE CONTROL 1 Operating mode 6 Fan speed selected Ventilation (fan only) 7 Horizontal flaps positioning indicator Heating (hea...
Page 11 - MY COMFORT SMART REMOTE CONTROL
11 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products 2 5 3 4 1 10 14 15 12 6 8 9 13 11 7 C MY COMFORT SMART REMOTE CONTROL Remote control description 1 ON/OFF Button 2 Mode selection button 3 Increase temperatu...
Page 13 - SUPER COMPLETE CONTROL FUNCTIONS FOR EFFICENT OPERATION (Cont.); -2 Intelligent Display On The Indoor Unit Indicates; Emergency Button; : Blue Led For Ionizer
13 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products SUPER COMPLETE CONTROL FUNCTIONS FOR EFFICENT OPERATION (Cont.) 4-2 Intelligent Display On The Indoor Unit Indicates The Operation Status. 4-3 Emergency func...
Page 14 - Turn off the unit and pull out the power plug.; Jumper cap
14 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products SUPER COMPLETE CONTROL FUNCTIONS FOR EFFICENT OPERATION (Cont.) 4-4 ADDRESS CONFIGURATION Sizes 18K – 24K If you are installing two indoor units in the same ...
Page 16 - SUPER COMPLETE SAFTY PROTECTIONS FOR SAFE OPERATION.; -1 Safety protections built in the system control; Auto restart Feature with backup memory.; -2 Safety protections built in the components of outdoor unit
16 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (5) SUPER COMPLETE SAFTY PROTECTIONS FOR SAFE OPERATION. 5-1 Safety protections built in the system control For Heat Pump and Cool only Systems - Auto restar...
Page 17 - (6) EFFICIENT AIR FILTERATION SYSTEM FOR CLEAN AND HEALTHY AIR
17 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (6) EFFICIENT AIR FILTERATION SYSTEM FOR CLEAN AND HEALTHY AIR
Page 18 - EFFICIENT AIR FILTERATION SYSTEM FOR CLEAN AND HEALTHY AIR (Cont.); -1 For indoor Units Sizes 18K – 24K; Optional set of air filters consists of tow filters :; Titanium
18 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products EFFICIENT AIR FILTERATION SYSTEM FOR CLEAN AND HEALTHY AIR (Cont.) 6-1 For indoor Units Sizes 18K – 24K Standard washable and anti bacteria air filters for d...
Page 20 - Painted steel guard for outdoor coil.; Long life and corrosion resistant
20 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (7) DURABLE FOR LONG LIFE AND CORROSION RESISTANT. 7-1 DURABLE OUTDOOR UNIT. • Long life and corrosion resistant - Weather proof made of chemically treated, ...
Page 21 - DESCREPTION
21 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (8) SUPER EASY AND FLEXIBLE INSTALLATION 8-1 AVAILABILITY OF ALL STANDARD ACCESSORIES SUPPLIED FROM FACTORY DESCREPTION CONFIGURATION QTY USAGE Battery 1.5 v...
Page 22 - -2 AVAILABILITY OF ALL OPTIONAL ACCESSRIES
22 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products SUPER EASY AND FLEXIBLE INSTALLATION (Cont.) 8-2 AVAILABILITY OF ALL OPTIONAL ACCESSRIES SUPPLIED FROM THE FACTORY AS PER THE REQUIREMENT DESCREPTION CONFIGU...
Page 24 - COOLING TEST RUNNING; Low Pressure Measuring.
24 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products SUPER EASY AND FLEXIBLE INSTALLATION (Cont.) 8-4 SUPER EASY AND FLEXIBLE INSTALLATION OF OUTDOOR UNIT. • Flexible unit installation on the wall or on the gro...
Page 25 - HEAT PUMP SYSTEMS; COOL ONLY SYSTEMS; Model S L Model S L
25 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products SUPER EASY AND FLEXIBLE INSTALLATION (Cont.) 8-5 Diameters of suction and liquid piping for outdoor and indoor units are designed for long refrigerant piping...
Page 26 - H = Maximum vertical distance between outdoor and indoor units.
26 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products L SUPER EASY AND FLEXIBLE INSTALLATION (Cont.) 8-6 FLEXIBLE OUTDOOR UNIT LOCATION WITH RESPECT TO INDOOR UNIT LOCATION The following data refers to the use o...
Page 27 - -7 EASY FILED ELECTRICAL WIRING BETWEEN POWER SUPPLY,; for the indoor unit from the outdoor unit.
27 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products LEGEND Earth L Live power supply. N Neutral power supply. R Live connection indoor/outdoor unit. C Neutral connection indoor/outdoor unit. Y Compressor contr...
Page 28 - -1 EASY SERVICE & MAINTENANCE OF INDOOR UNIT; STANDARD FILTERS REMOVAL
28 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (9) EASY SERVICE & MAINTENANCE. 9-1 EASY SERVICE & MAINTENANCE OF INDOOR UNIT • Easy unit handling due to compact dimensions and light weight. • Easy...
Page 29 - -2 SUPER EASY SERVICE & MAINTENANCE OF OUTDOOR UNIT; High
29 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products EASY SERVICE & MAINTENANCE (Cont.) 9-2 SUPER EASY SERVICE & MAINTENANCE OF OUTDOOR UNIT • Easy unit handling due to compact dimensions and light weig...
Page 30 - (10) SYSTEM TEST FUNCTION, WHICH IS USED BY INSTALLER AND ALSO; The system test function is initiated via the remote control.
30 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products (10) SYSTEM TEST FUNCTION, WHICH IS USED BY INSTALLER AND ALSO BY SERVICEMAN TO VERIFY THAT THE SYSTEM IS WORKING CORRECTLY. This test initiated via the remo...
Page 31 - COMPLETE SELF DIAGNOSTIC FUNCTION; EXPLAINATION OF SELF-DIAGNOSTIC FUNCTION FOR SIZES 18K – 24K; Indoor Unit
31 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products 11. COMPLETE SELF DIAGNOSTIC FUNCTION WHICH IS USED BY INSTALLER AND ALSO BY SERVICEMAN TO DETECT AND CORRECT MALFUNCTIONS EXPLAINATION OF SELF-DIAGNOSTIC FU...
Page 32 - EXPLAINATION OF SELF-DIAGNOSTIC FUNCTION FOR SIZES 30K – 36K; The system will be allowed to restart on its own.; Notes
32 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products COMPLETE SELF DIAGNOSTIC FUNCTION WHICH IS USED BY INSTALLER AND ALSO BY SERVICEMAN TO DETECT AND CORRECT MALFUNCTIONS (Cont.) EXPLAINATION OF SELF-DIAGNOSTI...
Page 33 - Difference; detect a malfunction and the unit will not operate properly.
33 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products OPERATING LIMITS* COOLING HEATING Difference Dry Bulb Temp. C° Wet Bulb Temp. C° Difference Dry Bulb Temp. C° Wet BulbTemp. C° Indoor temperature Maximum Min...
Page 34 - PRODUCT ORDERING DATA; Unit Model Identification For Sizes 18K – 24K:; System; Unit Family; Unit Type
34 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products PRODUCT ORDERING DATA Unit Model Identification For Sizes 18K – 24K: Engineering Part Numbers for Units: SPLIT SYSTEMS FOR LOCAL MARKET Indoor Unit Outdoor U...
Page 35 - Unit Model Identification For Sizes 30K – 36K:
35 Technical Bulletin TB/1 Issue Date : 01/01/2009 Revision No. : 0 Revision Date: 01/01/2009 Technical Support / Marketing Dept. RLC Products PRODUCT ORDERING DATA Unit Model Identification For Sizes 30K – 36K: Engineering Part Numbers for Units: SPLIT SYSTEMS FOR LOCAL MARKET Indoor Unit Outdoor U...