Page 2 - ENGLISH; IR Remote Control; Contents; Page
GB - 1 4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0Split system “Global cassette” indoor unit ENGLISH IR Remote Control “Room Controller” “Zone Manager” The unit can be used with infrared Remote Control, with the Carrier “RoomController” or “Zone Manager” remote control. Carrier “Room contro...
Page 3 - General information; System description
4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0 GB - 2 General information A. Outdoor unit B. Indoor unit C. Room Controller(if foreseen) 1. Air return 2. Air filters 3. Air supply 4. Operation indicator lightand receiver of remotecontrol signals (if foreseen) 5. Nameplate 6. Interconnecting tu...
Page 4 - Indoor unit LEDs; Unit warning lights and controls - Fault code; Table II: Periodical checks; Code
4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0 GB - 3 E N G L I S H Indoor unit LEDs Information concerning indoor unit operation, timer status anddiagnostic is given by 3 LEDs located on the unit. • THE GREEN LED ( P ) shows the following conditions: - Fault codes (diagnostic);- During normal...
Page 5 - Correct cleaning; Before a long shutdown period
4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0 GB - 4 Optimum comfort and minimum powerconsumption Keep room temperature at a comfortable level. Only open doors and windows when strictly necessary. When cooling, avoid direct sunlight in the room: if possible, drawthe curtains or close the shad...
Page 6 - “Room controller” general information and characteristics; Table I: Unit protection devices
GB - 5 4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0 E N G L I S H “Room controller” general information and characteristics Table I: Unit protection devices WARNING: During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor unit i...
Page 7 - “Room controller” wired control
4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0 GB - 6 Power up All segments of the LCD should be energized for five seconds.The mode, fan, louver, desired temperature and configurationinformation should be read from the EEPROM.If the EEPROM values are not valid, the following should be usedas ...
Page 8 - Louver mode selection; ” and “; ” button; ” button; up
GB - 7 4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0 E N G L I S H “Room controller” wired control Auto mode setting will be displayed by blinking the fan Mediumspeed and High speed icons in order (Med then Hi then repeat). Low Medium High Automatic(Fan speed will automatically switch to thev...
Page 9 - Troubleshooting
4 0 K M C - - - - - - 3 1 0 / 40KMQ- - - - - - 3 1 0 GB - 8 Troubleshooting No Room controller LCD display: • Mis-wiring of the 12 volt power to Room Controller control; verify that + 12 V and Ground are connected to the properterrminals of the Controller (Reference Installation wiringsection for co...