Page 2 - Table 1—Control Box Modification Kits; UNIT

2. Route outdoor fan motor wires into control box. Connect 1 wire to the blue wire from OF2 terminal on the defrost controlboard. Connect the remaining wire to the orange wire from L2on contactor using wire nuts. 3. Route orange wire from LPS into control box and connect to Y push-on terminal. Conne...

Page 3 - Fig. 2—Control Box Prior to Modification; Fig. 3—Modified Control Box

Fig. 2—Control Box Prior to Modification A89279 WARNING: CONTAINS R-22 VAPOR CHARGE RELIEVE PRESSURE AT SCHRADER VALVE BEFORE REMOVING BRACKET. 38HQ500402 Fig. 3—Modified Control Box A94138 P/N 315780-201 REV A THIS CONTROL BOX ASSEMBLY H A S B E E N M O D I F I E D T O T H E 38SQ100 SERIES. FOR CON...

Page 4 - Fig. 4—Modified Wiring; DFT

Fig. 4—Modified Wiring A92323 THERMOSTAT SUBBASE HH93AZ183 OR HH93AZ186 38SQ COMPRESSOR SECTION DEFROST BOARD INDOOR UNIT ELECTRIC HEATER TERMINAL BOARD R R R C C C Y Y Y G G O O O P W 3 E E W 2 W 2 W 2 X L L † ** JUMPER WIRE REQUIRED FOR SUPPLEMENTAL HEAT L.E.D. † REMOVE JUMPER WIRE(S) WITH APPLICA...