Carrier 38AUZ- Manuals

Carrier 38AUZ– Installation Manual, Manual in PDF format online.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56

Summary

Page 2 - SAFETY CONSIDERATIONS; WARNING; INSTALLATION GUIDELINE

2 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for inf...

Page 3 - CAUTION

3 Same tube sizes are capable of handling higher flowrates (expressed as tons of cooling capacity) with Puron refrigerant compared to R--22 at constant pressure drops. For example, a 1 / 2 --inch OD liquid line is rated at 33% higher tons with Puron R than with R--22 (at 5 _ F pressure drop). A 1 1 ...

Page 10 - A U Z

10 Model Type 38AU= Carrier Condensing Unit Puron ® R --- 410A Refrigerant Type of Coil D = Dual Circuit, A/C Scroll Compressor Z = Single Circuit, A/C Scroll Compressor Refrigerant Options A = None B = Low Ambient Nominal Tonnage 16 = 15 Tons 25 = 20 Tons Not Used A = Not Used Not Used 0 = Not Used...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28

Summary

Page 2 - INSTALLATION GUIDELINE; Replacement /Retrofit – R22 to Puron

2 INSTALLATION GUIDELINE Replacement /Retrofit – R22 to Puron ® Replacement/retrofit installations require change-out of outdoor unit, metering device, and filter driers. Change-out of indoor coil (evaporator) and interconnecting tubing is recommended. Existing evaporator coil – If the existing evap...

Page 6 - A U Z

6 Fig. 2 — Model Number Nomenclature Fig. 3 — Serial Number Nomenclature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 3 8 A U Z A 0 4 A 0 G 6 – 0 A 0 A 0 _____________ ____ Model Type Packaging 38AU= Carrier Condensing Unit Puron r R --- 410A Refrigerant 0 = Standard Type of Coil Electrical Options ...

Page 7 - INSTALLATION; Fig. 4 — Service Clearance Dimensional Drawing; CONSIDER SYSTEM REQUIREMENTS; UNIT DAMAGE HAZARD

7 . INSTALLATION Jobsite Survey Complete the following checks before installation. 1. Consult local building codes and the NEC (National Electrical Code) ANSI/NFPA 70 for special installation requirements. 2. Determine unit location (from project plans) or select unit location. 3. Check for possible...