Page 2 - not sling unshielded unit Skidded unit may be
Lift unit at points G,H, J, and K (Fig. 2). Use eyebolts and washers supplied in parts package. Do not sling unshielded unit Skidded unit may be slung, provided sling does not contact unit sides. Do not roll unskidded unit on pipes or wooden pilings. COIL SECTION COM PR SECTION 4- r A - 4 ^ COIL COM...
Page 5 - must be wired to be opened by control from a
Fig. 9 — Recommended Filter-Drier(s) and Sight Glass Locations Table 5 — Filter-Drier Replacement Parts and Data F I L T E R - D R I E R U N I T P a r t N o , Q t y C o n n . S i z e R e p l a c e m e n t P a r t N o . C o r e Q t y 3 8 A D 0 2 4 KH43LE123 1 Same 0 3 8 A D 0 2 8 KH43LE12) 2 =/s Some...
Page 6 - Control Circuit Wiring —; Internal control voltage
Table 6 — Electrical Data (3-Phase, 60-Hz) f Shaded values are LRA drawn by first winding of part-winding start units (not standard on 38AB054,064, but may be field modified) See Note 1 Larger value is total LRA. FLA — Full Load Amps ICF — Maximum Instantaneous Current Flow (sum of LRA of last compr...
Page 7 - lEh
Table 7 — Maximum Field Wire Sizes U N I T S I Z E V O L T S ( 6 0 - H z y W I R E S I Z E C O N N . 3 8 A D 024,028,034 208 230 6 AWG to 350 MCM TB 460 575 14 AWG to 2/0 044 460 575 208 230 6 AWG to 350 MOV! TB CT 3 8 A B 054,064 208 230 6 AWG to 350 MCM CT 460 575 6 AWG to 3/0 084 All 6 AWG to 350...
Page 9 - Table 9 — Physical Data; Time Guard Circuits
Table 9 — Physical Data U N I T 3 8 A D 0 2 4 3 8 A D 0 2 8 3 8 A D 0 3 4 3 8 A D 0 4 4 3 8 A B 0 5 4 3 8 A B 0 6 4 3 8 A B 0 8 4 O P E R W T ( l b ) 1750 1900 2300 ' 3200 3145 3830 4960 R E F R I G E R A N T R-22 O p e r C h g ( l b ) * 28 0 30 5 35 5 66 0 57 0 71 0 132 0 C O M P R E S S O R Recipr...
Page 11 - Fig. 16 — Fan Adjustment
allow unit to start under low-ambient conditions. An evaporator freezestat must also be installed in series with the control thermostat(s) to prevent coil freeze-up (See lower part of Fig 15 — EDT Wiring section.) LIQUID LINE PRESSURESTAT - Connect to system liquid line service valve port. Connect s...
Page 12 - C A R R I E R A I R C O N D I T I O N I N G C O M P A N Y • S Y R A C U S E , N E W Y O R K
i For replacement items use Carrier Specified Parts. M a n u f a c t u r e r r e s e r v e s t h e r i g h t t o c h a n g e a n y p r o d u c t s p e c i f i c a t i o n s w i t h o u t n o t i c e . C A R R I E R A I R C O N D I T I O N I N G C O M P A N Y • S Y R A C U S E , N E W Y O R K Tab 4 F...