Page 4 - Table 3 — Accessories; ism; ism I; ISiíSl; WM
Table 3 — Accessories PART NO. 38CQ900081 38CQ900111 38QB90002106 38HQ9000011 28VQ900011 38RQ900081 38RQ900001 38HQ900002 38CQ900172 38RQ900091 DESCRIPTION Low-Voltage Control — Honeywell Thermostat HH07AT171 and Thermostat Subbase HH93AZ173 — (Automatic Changeover) Low-Voltage Control — Honeywell T...
Page 5 - Step 4 — Make Electrical Connections; Do not apply units in system where voltage may; Fig. 4 — Urte Power Connections
r REPLACE THE ACCURATER™ REFRIG ERANT CONTROL PISTON IN THE INDOOR COIL AS REQUIRED before connecting refrig erant lines. See Table 1. Correct piston is supplied with 38QB unit. For piston replacement instruc tions, see AccuRater Servicing on page 13. CONNECT REFRIGERANT LINES to fittings on unit...
Page 6 - Fig. 5 — Control Circuit Connections
THERMOSTAT SUBBASE HH93AZI73 OR HH93AZI75 40AQ OR 40QB FAN COIL COOLING CONTROL KIT TERMINAL BOARD 38QB TERMINAL BOARD COOLING AND ONE-STAGE HEATING (38QB/40AQ 0R40QB WITHOUT ELECTRIC HEATER) THERMOSTAT SUBBASE HH93AZI73 ORHH93AZI75 40AQ OR 40QB ELECTRIC HEATER TERMINAL BOARD 38QB TERMINAL BOARD COO...
Page 8 - m Ì; Fig. 6 — 38QB Refrigerant Flow Diagrams
Table 6 — Service Data Refrigerant Charging — The 38QB units contain correct operating charge for complete system when connected to28HQ,VQ,40QB or 40AQ indoor units with 25 ft (7.6 m) of tubing of recommended diam eter. Charge adjustment is required on other sys tems. Adjust system charge for refr...
Page 9 - Unit Single-Phase Compressors; Compressor Removal; Be sure system pressure is 0 psig before proceeding.; CAUTION: Aíuíiwíusííj ititsing; Fig. 7 — Component Location; have ftm extiugaisfeef âïtdior qtjieucbifig; cîoîît
6. From intersect point, project vertically down ward to chart suction pressure line. Compare chart suction pressure to unit suction pressure (Step 2). 7. If unit suction pressure is lower than chart pres sure, add refrigerant to system until chart pressure is reached. If unit suction pressure is ...
Page 10 - CHARGING AND PRESSURE CHECK CHARTS; Cooling Cycle Charging Chart; Cooling Cycle Charging Chart; Heating Cycle Operation Check Chart
connect high- and low-voltage power wiring; and replace louvered casing. 13. Replace top cover by running 4 screws into orifice loosely (2 on each side of unit) and tighten when cover is in place. Replace remain ing screws. 14. Evacuate and recharge system. CHARGING AND PRESSURE CHECK CHARTS PSIG (...
Page 13 - Components
With a low-side leak there is always some pressure in the liquid line. However, compressor motor tem perature increases because of insufficient suction gas cooling. This causes internal thermostat to actuate and stop compressor. When compressor stops, system pressure equalizes and contacts on press...
Page 15 - Fig. 22 — Positioning Hose to Spray Coil
Page 16 - TROUBLESHOOTING CHART — COOLING CYCLE; Os
Page 17 - TROUBLESHOOTING CHART — HEATING CYCLE