Summary
SWEAT CONNECTIONS 1. Cut tubing to length and remove burrs. Be care ful not to expand tubing. 2. Clean tubing. Remove plug and nut from fitting. 3. IMPORTANT - Remove O ring from inside fitting. Wrap entire valve with wet rag. 4. Insert tubing in fitting and solder with low- temperature solder (450...
3. A high-density fiberglass (2 lb minimum den sity) or semirigid foamed insulation such as Styrofoam will be required inside the ducts to prevent air erosion. The insulation must be firmly secured in the discharge duct near the blower discharge to withstand the high air velocity. Fan Adjustment - ...
ELECTRICAL DATA (Cont) Refer to Table 3 for 09BB fan motor char acteristics. Refer to Table 4 for wire and fuse sizing. Refer to Fig. 7 for combination field wiring. Table 3 - 09BB Condenser Fan Motor HORSEPOWER FULL LOAD AMPS LOCKED ROTOR AMPS 1 7 18 Table 4 - Wire and Fuse Sizing VOLTAGE WIRE WIR...