Summary

Page 2 - Fig. 2 — 06E Hermetic Compressor Units; IVa; Fig. 3 — 07E Water-Cooled Condensing Units

F DISCHARGE VALVE ODF^ '• . (ROTATES 180°) n D DIAM CONCEN RIG KNOCKOUT E SUCTION VALVE ODF (ROTATES 360°AT , 90° INTERVALS) * Install pressure relief device in discharge line Pressure relief setting is 465 psig tOverall width includes projection of fuse holders and/or switches j.Maximum height is t...

Page 3 - Table 2 — Electrical Data; ELECTRICAL REQUIREMENTS

Table 2 — Electrical Data volts / pha U 208/3 230/3 NDSV 208 220-240 COND Wire Max Fusetron Wire Max Fusetron UNIT KW LRA FLA OLTA Size* Ft Si ze LRA FLA OLTA Size* Ft Size 07 E (AWG No.) Wire (Amps) (AWG No.) Wire (Amps) B022 22 6 310 71 99 2 73 100 280 65 90 8 2 88 100 B027 31.4 457 86 121 0 62 12...

Page 6 - CAUTION Do not use a fcattiary powered test; lamp; to check sensors. Excessive current can; STEPS

Check low-pressure switch by slowly closing suction shutoff valve or by completely closing hquid line shutoff valve. A decrease of suction pressure will follow. Compressor should shut off within 4 psi of values shown in Table 1. HIGH-PRESSURE SAFETY SWITCH LOW-PRESSURE SAFETY SWITCH RANGE ADJUSTMENT...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20

Summary

Page 4 - Fig. 3 — 06E Hermetic Compressor Units

4 DIMENSIONS (in.) 06E UNIT VOLTAGE A B C D E F G V022 208/230 48 1 / 4 35 36 7 / 8 1 1 / 2 27 1 / 2 1 19 1 / 2 460,575 48 1 / 4 29 36 7 / 8 1 1 / 2 26 1 19 1 / 2 W027 208/230 50 1 / 4 35 36 7 / 8 1 1 / 2 27 1 / 2 1 19 1 / 2 460,575 50 1 / 4 29 36 7 / 8 1 1 / 2 26 1 19 1 / 2 W033 208/230 50 1 / 4 35...

Page 6 - Fig. 6 — Control Circuit Wiring for 06E/07E Units

6 Fig. 6 — Control Circuit Wiring for 06E/07E Units AUX — Auxiliary C — Compressor Contactor C1 — Compressor Contactor(XL start and first step of PW start) C2 — Compressor Contactor(PW second step) CH — Crankcase Heater CHR — Crankcase Heater Relay CR — Control Relay DTS — Discharge Temperature Sens...

Page 7 - Factory Sales Representative for other refrigerants.; Table 2 — 06E Physical Data; REFRIGERANT

7 PRE-START-UP Evacuate, Dehydrate, and Leak Test — The entire refrigerant system must be evacuated, dehydrated and leak test-ed by methods described in Carrier Standard Service Tech-niques Manual, Chapter 1, Section 1-6 and 1-7. Use sight glassmethod to charge system. See Section 1-8 of Service Tec...