Page 3 - F06-02 FDDI SmartSwitch Interface Module User’s Guide; NOTICE; FCC NOTICE
7F06-02 FDDI SmartSwitch Interface Module User’s Guide i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes...
Page 7 - CONTENTS
7F06-02 FDDI SmartSwitch Interface Module User’s Guide v CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual ....................................................................... 1-1 1.2 The 7F06-02 Module ................................................................... 1-11.2.1 Cable Type an...
Page 9 - CHAPTER 1; F06-02 FDDI SmartSwitch Interface; USING THIS MANUAL; Introduction
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1-1 CHAPTER 1 INTRODUCTION Welcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User Guide . This guide is a simple reference for installing and using the 7F06-02 Module. Before installing this module, you should carefully read...
Page 10 - Cable Type and FPIMs
Chapter 1: Introduction 1-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1.2.1 Cable Type and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 SmartSwitch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs. There...
Page 11 - FEATURES
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1-3 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-...
Page 12 - Connectivity; X00 SmartSwitch Control Module User’s Guide
Chapter 1: Introduction 1-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1.3.3 Connectivity The 7F06-02 Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection provides power to the 7F06-02 Module and a channel for communication with t...
Page 13 - GETTING HELP; Your Cabletron Systems service contract number
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1-5 1.5 GETTING HELP If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center: Before calling t...
Page 15 - CHAPTER 2; FPIM MODULE SPECIFICATIONS
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 2-1 CHAPTER 2 NETWORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7F...
Page 16 - Network Requirements; Transmitter Power Parameters
Chapter 2: Network Requirements 2-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD. 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded Twisted Pair (UTP)...
Page 17 - Better than
Chapter 2: Network Requirements 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 2-3 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector. The specifications for both devices a...
Page 19 - CHAPTER 3
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-1 CHAPTER 3 INSTALLATION/REMOVAL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMAC SmartSwitch • 7C04 Workgroup SmartSwitch • 7C04-R Workgroup SmartSwitch Also included in the chapter are ins...
Page 20 - INSTALLING FPIMS; Remove the module if it is installed in the 7C03 MMAC SmartSwitch; Installing an FPIM
Chapter 3: Installation/Removal 3-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3.2 INSTALLING FPIMS The 7F06-02 module is shipped without FPIMs. To install an FPIM, follow the procedure below: 1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the p...
Page 21 - Installing in the 7C03 SmartSwitch; As a precaution, power down the MMAC 8 before beginning the; Installing the 7F06-02 Module in the
Chapter 3: Installation/Removal 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-3 3.3 INSTALLING/REMOVING THE 7F06-02 MODULE The following procedure details the installation and removal procedure for the 7F06-02 module. 3.3.1 Installing in the 7C03 SmartSwitch The 7F06-02 Module is installe...
Page 22 - Removing from the 7C03 SmartSwitch; SmartSwitch; Screw
Chapter 3: Installation/Removal 3-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3.3.2 Removing from the 7C03 SmartSwitch The 7F06-02 Module inserted in the 7C03 MMAC SmartSwitch can be removed upon proper removal of power. Follow the steps below and refer to Figure 3-3 to remove the modul...
Page 25 - Screws
Chapter 3: Installation/Removal 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-7 3.3.4 Removing the 7F06-02 from the 7C04 or 7C04-R Workgroup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R Workgroup SmartSwitch, can be removed whenever necessary. Follow the steps below ...
Page 26 - Removing the 7F06-02 Module from the 7C04-R Workgroup; Ejector Tabs
Chapter 3: Installation/Removal 3-8 7F06-02 FDDI SmartSwitch Interface Module User’s Guide Figure 3-7 Removing the 7F06-02 Module from the 7C04-R Workgroup SmartSwitch FANS SN 4 3 2 1 Ejector Tabs Screws
Page 27 - CHAPTER 4; DIAGNOSTIC AND MONITORING SYSTEM; LANVIEW LEDs; A Link Status
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 4-1 CHAPTER 4 TROUBLESHOOTING 4.1 DIAGNOSTIC AND MONITORING SYSTEM The 7F06-02 Module uses LANVIEW, Cabletron Systems’ built-in visual diagnostic and status monitoring system. With LANVIEW LEDs the status of each transmit and receive port on the...
Page 28 - PORT RECEIVE LEDS; Table 4-1 indicates the state of the receive port.; PORT TRANSMIT LEDS; Table 4-2 indicates the state of the transmit port.; Port Receive LEDs; Port Transmit LEDs; LED Color; Link LEDs; State
Chapter 4: Troubleshooting 4-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 4.2 PORT RECEIVE LEDS Table 4-1 indicates the state of the receive port. 4.3 PORT TRANSMIT LEDS Table 4-2 indicates the state of the transmit port. 4.4 A/B LINK LEDS Table 4-3 indicates the state of the A/B Link LE...
Page 31 - CHAPTER 5; STANDARDS
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 5-1 CHAPTER 5 TECHNICAL SPECIFICATIONS This chapter includes the technical specifications for 7F06-02 module. Cabletron Systems reserves the right to change these specifications at any time without notice. 5.1 STANDARDS IEEE 802.1D IEEE 802.3i 1...
Page 32 - SAFETY; This equipment meets the safety requirements of:; SERVICE
Chapter 5: Technical Specifications 5-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. This equi...