Page 3 - C105 Overview and Setup Guide; NOTICE; FCC NOTICE
6C105 Overview and Setup Guide i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The har...
Page 7 - CONTENTS; CHAPTER 1
6C105 Overview and Setup Guide v CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Guide ......................................................................... 1-1 1.2 Structure of This Guide................................................................ 1-1 1.3 Document Conventions ..................
Page 9 - Welcome to the Cabletron Systems; and Setup Guide; . This guide explains how to set up and configure the; USING THIS GUIDE; This guide is organized as follows:; Introduction; , provides manual organizational information,; Installation Requirements and Specifications; Chapter 3
6C105 Overview and Setup Guide 1-1 CHAPTER 1 INTRODUCTION Welcome to the Cabletron Systems 6C105 SmartSwitch 6000 Overview and Setup Guide . This guide explains how to set up and configure the Cabletron Systems 6C105 SmartSwitch 6000 chassis. 1.1 USING THIS GUIDE Read through this guide completely t...
Page 10 - DOCUMENT CONVENTIONS; Note; Caution
Chapter 1: Introduction 1-2 6C105 Overview and Setup Guide 1.3 DOCUMENT CONVENTIONS Throughout this guide the following symbols are used to call attention to important information. 1.4 USING THE 6C105 MANUAL SET Other manuals have been developed for the interface modules that can be installed in the...
Page 11 - GETTING HELP; Your Cabletron Systems service contract number; Service and Support
Getting Help 6C105 Overview and Setup Guide 1-3 1.5 GETTING HELP If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center: Before calling the Cabletron Systems Global Call Ce...
Page 12 - OVERVIEW; illustrates the 6C105 equipped with redundant; The 6C105 Chassis with Redundant Power Supplies
Chapter 1: Introduction 1-4 6C105 Overview and Setup Guide 1.6 OVERVIEW The Cabletron Systems 6C105 chassis design provides five 2.4-inch slots that can contain a variety of interface modules. The chassis supports redundant power supplies, LANVIEW Diagnostic LEDs, and is 19-inch rack mountable. All ...
Page 13 - FEATURES; Redundant Power Supply Modules; Chapter 2; Installation; , for a full explanation of the power; Power Supply Status Via Local Management; If the 6C105 is configured with a single power supply module it; must; be located in slot PS1.
Features 6C105 Overview and Setup Guide 1-5 1.7 FEATURES Redundant Power Supply Modules The 6C105 supports two power supply modules which reside in the slots labeled PS1 and PS2. Each power supply module supports an ac input connector that allows each power supply to be connected to a separate ac po...
Page 14 - Rack Mountable Chassis
Chapter 1: Introduction 1-6 6C105 Overview and Setup Guide Auto-Ranging Power Supplies The 6C105 power supply modules automatically adjust to the input voltage and frequency. No additional adjustments are necessary. Hot Swapping To reduce network downtime, the power supply modules are also hot swapp...
Page 15 - CHAPTER 2; This chapter describes the following:; SITE GUIDELINES; Only qualified personnel should install or service this unit.
6C105 Overview and Setup Guide 2-1 CHAPTER 2 INSTALLATION REQUIREMENTS AND SPECIFICATIONS This chapter describes the following: • Site guidelines that must be met before installing a 6C105 into a rack or cabinet • 6C105 configuration guidelines • Operating specifications for the 6C105 enclosure and ...
Page 16 - CONFIGURATION GUIDELINES; Environment; Operating Temperature:; Regulatory Compliance
Chapter 2: Installation Requirements and Specifications 2-2 6C105 Overview and Setup Guide 2.2 CONFIGURATION GUIDELINES The 6C105 has 5 slots that accept interface modules. The slots are numbered 1 to 5 beginning from the left. There are two additional slots located on the far right of the chassis t...
Page 17 - Physical Specifications
Operating Specifications 6C105 Overview and Setup Guide 2-3 2.3.1 Physical Specifications The physical specifications for the 6C105 chassis, 6C205-1, 6C205-2, 6C205-3 power supply modules and the 6C405 fan tray module are as follows: 6C105 Chassis 6C205-1 Power Supply 6C205-2 Power Supply 6C205-3 Po...
Page 18 - Power Supply Requirements; There are two LEDs on the power supply.
Chapter 2: Installation Requirements and Specifications 2-4 6C105 Overview and Setup Guide 2.3.2 Power Supply Requirements The power supply requirements for the 6C205-1, 6C205-2 and 6C205-3 power supply modules are as follows: 6C205-1 AC Power Supply 6C205-2 DC Power Supply 6C205-3 AC Power Supply 2...
Page 19 - Power Supply LEDs
LEDs 6C105 Overview and Setup Guide 2-5 Figure 2-1 Power Supply LEDs Table 2-1 Power Supply LED States and Their Definitions LED Name Color Status PWR (Power) Green All outputs and input of the power supply are within regulation. Red Any output or input of the specific power supply is out of regulat...
Page 20 - for the location of the fan tray LED.; Fan Tray LED; Green; Fan Tray LED
Chapter 2: Installation Requirements and Specifications 2-6 6C105 Overview and Setup Guide 2.4.2 Fan Tray LED The following table describes the different states of the fan tray LED and their definitions. Refer to Figure 2-2 for the location of the fan tray LED. Figure 2-2 Fan Tray LED Table 2-2 Fan ...
Page 21 - CHAPTER 3
6C105 Overview and Setup Guide 3-1 CHAPTER 3 6C105 SETUP This chapter contains instructions on setting up the Cabletron Systems 6C105 chassis. A Phillips screwdriver is needed to install the unit in a 19-inch equipment rack, to install the cable management bar, to secure the power supply module(s) a...
Page 22 - Installation Order; Install the cable management bar.
Chapter 3: 6C105 Setup 3-2 6C105 Overview and Setup Guide 3.2 SETTING UP THE 6C105 The following sections describe the procedures that must be followed to complete the installation of the 6C105. 3.2.1 Installation Order Once a suitable site has been chosen, the 6C105 can be installed. The chassis ca...
Page 23 - To install the cable management bar, proceed as follows:; Installing the Cable Management Bar
Setting Up the 6C105 6C105 Overview and Setup Guide 3-3 3.2.2 Installing the Cable Management Bar To install the cable management bar, proceed as follows: 1. Remove the cable management bar from the shipping box. Ensure that there are four screws inside the bag with the cable management bar. 2. Refe...
Page 24 - The 6C105 can be mounted in a standard 19-inch equipment rack.; Read
Chapter 3: 6C105 Setup 3-4 6C105 Overview and Setup Guide 3.2.3 Rack Mounting the 6C105 The 6C105 can be mounted in a standard 19-inch equipment rack. Two people may be required to lift the chassis into place. The chassis is secured with ten screws, five on each side. Using the screws provided with ...
Page 25 - Attaching the Electrostatic Discharge Wrist Strap; ESD Grounding Receptacle
Setting Up the 6C105 6C105 Overview and Setup Guide 3-5 3.2.4 Attaching the Electrostatic Discharge Wrist Strap The Electrostatic Discharge (ESD) Wrist Strap must be attached before handling the power supplies, fan tray, or modules for the 6C105. In addition, observe all precautions when handling th...
Page 26 - Installing a Power Supply Module; To install the power supply(ies) into the 6C105 chassis, refer to
Chapter 3: 6C105 Setup 3-6 6C105 Overview and Setup Guide 3.2.5 Installing a Power Supply Module You must install at least one power supply in the 6C105 chassis. One power supply provides sufficient power for most module configurations but a second power supply can be installed to provide a redundan...
Page 27 - Slide the power supply module into the slot labeled PS1 as follows:
Setting Up the 6C105 6C105 Overview and Setup Guide 3-7 4. Slide the power supply module into the slot labeled PS1 as follows: a. Hold the module by placing one hand on the handle located on the module front panel and using the other hand to support the body of the module. b. With the LED at the top...
Page 29 - Installing 6C105 Interface Modules
Setting Up the 6C105 6C105 Overview and Setup Guide 3-9 3.2.6 Installing 6C105 Interface Modules The 6C105 Interface Modules can be installed in any of the 5 slots that are available. To install a module, proceed as follows: 1. Remove the blank panel covering the slot in which the Interface Module w...
Page 30 - Installing a Module
Chapter 3: 6C105 Setup 3-10 6C105 Overview and Setup Guide Figure 3-5 Installing a Module 1 2 3 4 5 PS1 PS2 PlasticLocking Tab Slot Number 2361-02 2159-01 Circuit Card Card Guides Metal Back-Panel Plastic Locking Tab BackplaneConnector 1 2 14 13 COM CPU 3 4 5 6 7 8 9 10 11 12 15 16 6E252-17 Fast Ene...
Page 31 - To power up a 6C105 with ac power supply modules proceed as follows:
Powering Up a 6C105 with AC Power Supplies 6C105 Overview and Setup Guide 3-11 3.3 POWERING UP A 6C105 WITH AC POWER SUPPLIES To power up a 6C105 with ac power supply modules proceed as follows: 1. Plug one end of the power cord (supplied with the power supply) into the ac power socket on the bottom...
Page 32 - Power Supply DC ON/OFF Switch and DC Input Power Strip; DC Power Supply Requirement for Each Supply; USE 10 AWG SOLID COPPER CONDUCTORS ONLY.; DC Input Power Strip
Chapter 3: 6C105 Setup 3-12 6C105 Overview and Setup Guide Figure 3-6 Power Supply DC ON/OFF Switch and DC Input Power Strip DC Power Supply Requirement for Each Supply Each DC power supply input requires either a 48 VDC or 60 VDC power source, rated at a minimum of 17 Amps. ONLY QUALIFIED PERSONNEL...
Page 33 - 8/60 VDC Power Supply Connections
Powering Up a 6C105 with DC Power Supplies 6C105 Overview and Setup Guide 3-13 Installation Requirement Each DC power supply input requires either a 48 VDC or 60 VDC power source supplied by three 10 AWG (American Wire Gauge) copper wires. These wires must be terminated with either ring or spade ter...
Page 34 - REMOVING AND REINSTALLING THE FAN TRAY; and; Removing the Fan Tray; To remove the fan tray, refer to
Chapter 3: 6C105 Setup 3-14 6C105 Overview and Setup Guide If you experience any problems during the installation of the 6C105, contact Cabletron Systems Global Call Center for assistance. 3.5 REMOVING AND REINSTALLING THE FAN TRAY The 6C105 is equipped at the factory with a removable fan tray that ...
Page 35 - Reinstalling the Fan Tray; To reinstall the fan tray, refer to
Removing and Reinstalling the Fan Tray 6C105 Overview and Setup Guide 3-15 Figure 3-8 Removing the Fan Tray 3.5.2 Reinstalling the Fan Tray To reinstall the fan tray, refer to Figure 3-9 and proceed as follows: 1. Locate the ESD wrist strap shipped with the 6C105. Attach the ESD wrist strap to your ...