Page 2 - P a g e; SAFETY WARNINGS; INDOORS; NEVER ATTEMPT TO REPAIR THE APPLIANCE YOURSELF
2 | P a g e R e v 4 . 1 SAFETY WARNINGS This appliance must only be used INDOORS and in a well ventilated area only. DO NOT USE IN CARAVANS, TENTS, MARINE CRAFT, CARS, MOBILE HOMES. Failure to follow instructions in this manual could result in physical injury and/or property damage. Hazardou...
Page 3 - Position of Wok Cooker outlet pipe at the rear of the unit:; SAFETY PRECAUTIONS; Combustible material
3 | P a g e R e v 4 . 1 INSTALLATION – NOTES TO THE INSTALLER The LPG models & Natural models connected to a permanently fixed reticulated LP Gas supply, must be installed in accordance with AS/NZS 5601.1 by an authorised gas fitter / plumber Where the LPG models are used in quasi-outdoor/indoor...
Page 4 - For LP Gas Models; UNDER NO CIRCUMSTANCES SHOULD A NAKED FLAME BE USED IN CHECKING
4 | P a g e R e v 4 . 1 1. Remove all the packing materials from the appliance before connecting the gas . 2. Appliance Gas inlet fitting located at the rear of the appliance: ¼ ” BSPM for Natural Gas and for LP Gas, 5/8-18 UNF thread (known as 3/8 SAE male fitting). 3. Ensure that the gas supply co...
Page 5 - CORRECT ASSEMBLY OF BURNER HEAD; Make sure all connections are gas tight and have no gas leakage.; DO NOT ATTEMPT REPAIRS YOURSELF.
5 | P a g e R e v 4 . 1 CORRECT ASSEMBLY OF BURNER HEAD TO GAS FITTERS - BEFORE LEAVING AFTER INSTALLATION 1. Make sure all connections are gas tight and have no gas leakage. 2. Check that the aeration control is adjusted to the right position to enable the burner to achieve a blue and vigorous flam...
Page 6 - APPLIANCE DIMENSIONS; USING THE APPLIANCE; Follow these steps when operating the appliance:; LIGHTING THE APPLAINCE; Warning – Risk of deflagration!
6 | P a g e R e v 4 . 1 APPLIANCE DIMENSIONS COMPONENTS AND PARTS DC100NG-S & DC100-S DC200NG-S & DC200-S PARTS INDEX 1. Body 3. Outer Ring Brass Cap 5. Tray 7. Rubber Leg 2. Trivet 4. Inner Ring Brass Cap 6. Burner Head 8. Knob 9. Thermocouple OPERATING INSTRUCTIONS USING THE APPLIANCE Foll...
Page 7 - ADJUSTING THE FLAME; Do not use damaged pans, which do not sit evenly on; CAUTION - CORRECT PLACEMENT OF UTENSILS
7 | P a g e R e v 4 . 1 ADJUSTING THE FLAME 1. Turn the ignition knob to the required flame setting position as shown below . TURNING OFF THE COOKER 1. Turn the ignition knob fully back to the OFF position A few seconds after the burner is switched off, a sound (thud) will be produced. This is not a...
Page 8 - DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.; Keep the appliance clean regularly by wiping with a damp cloth.
8 | P a g e R e v 4 . 1 DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. MAINTENANCE. DO NOT MODIFY THIS APPLIANCE. Keep the appliance clean regularly by wiping with a damp cloth. Before checking and maintaining the appliance, make sure the main gas valve is turned off. Make sure the burner...
Page 9 - Ensure the appliance is tested for gas leakage after servicing.; TROUBLESHOOTING; Problem
9 | P a g e R e v 4 . 1 To replace the thermocouple disconnect the quick connect fitting and the earth ring from the gas valve. The bracket retaining the thermocouple is secured to the burner mounting bracket. The thermocouple head and threaded body is retained in the thermocouple bracket via two ...
Page 10 - TECHNICAL SPECIFICATION; coned; LP Gas; China; BROMIC PTY LTD; For service, spare parts and repairs, contact
10 | P a g e R e v 4 . 1 TECHNICAL SPECIFICATION Natural Gas Model Number DC100NG-S DC200NG-S Heat Capacity (MJ/hr) 15.00 30.00 Injector size (mm) Outer 1.65 1.65 Inner 0.70 0.70 pilot 0.90 0.90 Dimensions (mm) (H)145x(W)300x(D)382 (H)145x(W)720x(D)382 Net Weight (kg) 3.7 6.6 Gas Type NATURAL GAS Ga...
Page 11 - WARRANTY
11 | P a g e R e v 4 . 1 WARRANTY WARRANTY PERIOD Bromic Pty Limited (‘Bromic’) warrants to the original purchaser (‘the Purchaser) of this Bromic ‘Ring Burner’, that the Ring Burner will be free from defects or faults in materials and/or workmanship for 12 months from the date of purchase (‘the War...
Page 12 - Call
12 | P a g e R e v 4 . 1 Call 1300 276 642 (1300 BROMIC) or +61 2 9426 5222 Email us [email protected] Visit www.bromic.com/plumbing