Page 2 - BRIGGSandSTRATTON.COM; Briggs & Stratton Power Products Group, LLC; Thank you; Refer to the; Where to Find Us
2 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC 900 North Parkway Jefferson, WI 53549 Copyright © 2008 Briggs & Stratton Power Products Group,LLC. All rights reserved. No part of this material may bereproduced or transmitted in any form by any means withoutthe express wri...
Page 3 - Table of Contents
3 Español Table of Contents Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Operator Safety; Equipment Description; NOTICE
4 BRIGGSandSTRATTON.COM Operator Safety Equipment Description Read this manual carefully and become familiarwith your generator. Know its applications, itslimitations and any hazards involved. The generator is an engine–driven, revolving field, alternatingcurrent (AC) generator. It was designed to s...
Page 5 - The engine exhaust from this product contains; WARNING; WARNING
5 WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. WARNING Running engine gives off carbon monoxide, anodorless, colorless, poison gas. Breathing carbon monoxide can cause headache,fatigue, di...
Page 6 - Excessively low speeds impose a heavy load.; Generator produces hazardous voltage.
6 BRIGGSandSTRATTON.COM WARNING Contact with muffler area can result in seriousburns. Exhaust heat / gases can ignite combustibles,structures or damage fuel tank causing a fire. • DO NOT touch hot parts and AVOID hot exhaust gases. • Allow equipment to cool before touching. • Keep at least 5 feet (1...
Page 7 - Assembly; Generator; Unpack Generator; The generator is supplied with:; Install Wheel Kit; Install the wheel kit as follows:; Verify Engine Oil Level; Maintenance; CAUTION
Assembly Your generator requires some assembly and is ready for useafter it has been properly serviced with the recommended oiland fuel. If you have any problems with the assembly of your generator,please call the generator helpline at 1-800-743-4115 . If calling for assistance, please have the mode...
Page 8 - Add Fuel; Fuel must meet these requirements:; High Altitude; Avoid generator damage.
Add Fuel Fuel must meet these requirements: • Clean, fresh, unleaded gasoline. • A minimum of 87 octane/87 AKI (91 RON). High altitude use, see High Altitude . • Gasoline with up to 10% ethanol (gasohol) or up to 15% MTBE (methyl tertiary butyl ether) is acceptable. To protect the fuel system from g...
Page 9 - System Ground; Special Requirements; Connecting to a Building’s Electrical System; Clearances and Air Movement
9 System Ground The generator has a system ground that connects thegenerator frame components to the ground terminals on theAC output receptacles. The system ground is connected tothe AC neutral wire (the neutral is bonded to the generatorframe). Special Requirements There may be Federal or State Oc...
Page 10 - Features and Controls
10 BRIGGSandSTRATTON.COM Features and Controls Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls andadjustments. Save this manual for future reference. A - Spark ...
Page 11 - Cord Sets and Receptacles
Cord Sets and Receptacles Use only high quality, well-insulated, grounded extensioncords with the generator’s 120 Volt duplex receptacle.Inspect extension cords before each use.Check the ratings of all extension cords before you usethem. Extension cord sets used should be rated for 125 VoltAC loads ...
Page 12 - Operation; Starting the Engine
Operation Starting the Engine Disconnect all electrical loads from the generator. Use thefollowing start instructions: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate the unit on a level surface will cause the unit not to start or shut down duringoperation. 2. Turn t...
Page 13 - Connecting Electrical Loads; Don’t; Stopping the Engine; all
13 Connecting Electrical Loads 1. Let engine stabilize and warm up for a few minutes after starting. 2. Plug in and turn on the desired 120 and / or 240 Volt AC, single phase, 60 Hz electrical loads. NOTE: • DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles. • DO NOT connect 3-phase l...
Page 15 - Maintenance Schedule; Emissions Warranty; Generator Maintenance
15 Maintenance Maintenance Schedule Follow the hourly or calendar intervals, whichever occursfirst. More frequent service is required when operating inadverse conditions noted below. 1 Service more often under dirty or dusty conditions. General Recommendations Regular maintenance will improve the pe...
Page 16 - Engine Maintenance; Oil Recommendations; Checking Oil Level; Changing Engine Oil
16 BRIGGSandSTRATTON.COM Engine Maintenance Oil Recommendations We recommend the use of Briggs & Stratton WarrantyCertified oils for best performance. Other high-qualitydetergent oils are acceptable if classified for service SF, SG,SH, SJ or higher. DO NOT use special additives. Outdoor temperat...
Page 17 - Specifications; Service Spark Arrester
Service Air Cleaner Your engine will not run properly and may be damaged ifyou run it with a dirty air cleaner. Replace the air cleaner every 25 hours of operation or onceeach year, whichever comes first. Replace more often ifoperating under dirty or dusty conditions. To service the air cleaner, fol...
Page 18 - Check Valve Clearance; Carburetor Adjustment
18 BRIGGSandSTRATTON.COM Clean Cooling System Over time debris may accumulate in cylinder cooling fins andcannot be observed without partial engine disassembly. Forthis reason, we recommend you have a Briggs & Strattonauthorized dealer clean the cooling system ( A ) per recommended intervals (se...
Page 19 - Storage; Generator Storage; Cleaning; Long Term Storage Instructions; Oil Cylinder Bore; Protect Fuel System
19 Storage The generator should be started at least once every sevendays and allowed to run at least 30 minutes. If this cannot bedone and you must store the unit for more than 30 days, usethe following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in Clea...
Page 20 - Troubleshooting; Problem; Don't Overload Generator
20 BRIGGSandSTRATTON.COM Troubleshooting Problem Cause Correction Engine is running, but no ACoutput is available. 1. GFCI circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 1. Reset circuit breaker. 2. Contact Briggs & Stratton...
Page 21 - Warranties; Emissions Control System Warranty; Owner’s Warranty Responsibilities
21 Warranties Emissions Control System Warranty Briggs & Stratton Corporation (B&S), the California AirResources Board (CARB) and the United StatesEnvironmental Protection Agency (U.S. EPA) Emissions Control System Warranty Statement (Owner’sDefect Warranty Rights and Obligations) California...
Page 22 - Emission Information; Emissions Durability Period
22 BRIGGSandSTRATTON.COM 2. Length of Coverage B&S warrants to the initial owner and each subsequentpurchaser that the Warranted Parts shall be free fromdefects in materials and workmanship which caused thefailure of the Warranted Parts for a period of two yearsfrom the date the engine is delive...
Page 24 - Portable Generator; Product Specifications
24 BRIGGSandSTRATTON.COM 24 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC 900 N. Parkway Jefferson, Wisconsin, 53549 U.S.A. Portable Generator Power Ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of Automotive Engin...
Page 25 - Generador portátil; Manual del Operario; BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
Generador portátil Manual del Operario BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC JEFFERSON, WISCONSIN, U.S.A. Este generador está clasificado conforme a la norma C22.2 No. 100-04 (motores y generadores) de la CSA (Canadian Standards Association [Asociación canadiense de normalización]).
Page 26 - Dónde encontrarnos
2 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC. 900 North Parkway Jefferson, WI 53549 Copyright © 2008 Briggs & Stratton Power Products Group,LLC. Reservados todos los derechos. Queda prohibida lareproducción o transmisión total o parcial de este material,sea cual sea la...
Page 27 - Tabla de Contenido
3 Español Tabla de Contenido Seguridad de operario . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Descripción del equipo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Reglas de seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 28 - Seguridad de operario; Descripción del equipo; F - Superficie Caliente; AVISO
Seguridad de operario Descripción del equipo Lea atentamente este manual y familiarícese conel generador. Conozca sus aplicaciones,limitaciones y riesgos. Este generador funciona en base a un motor de campoeléctrico giratorio y de corriente alterna (CA). Fue diseñadocon la finalidad de proveer energ...
Page 31 - Montaje; Controles y características; Desembalaje del generador; El generador se entrega con:; Instale el juego de ruedas; Mantenimiento; PRECAUCIÓN
Montaje Su generador requiere de ciertos procedimientos de montajey solo estará listo para ser utilizado después de haberlesuministrado servicio con el combustible y aceiterecomendados.Si usted tiene problemas con el montaje de su generador,por favor llame a la línea de ayuda para generadores al (80...
Page 32 - Agregue combustible; El combustible debe reunir los siguientes requisitos:; Gran altitud; ADVERTENCIA
Agregue combustible El combustible debe reunir los siguientes requisitos: • Gasolina sin plomo limpia y nueva. • Un mínimo de 87 octanos/87 AKI (91 RON). Para uso a gran altitud, consulte Gran altitud . • El motor admite gasolina con hasta un 10% de etanol (gasohol) o hasta un 15% de MTBE (éter meti...
Page 33 - Tierra del sistema; Requisitos especiales; • En algunas zonas, es obligatorio registrar los; Conexión al sistema eléctrico de un edificio; Espacio libre alrededor del generador
Tierra del sistema El generador dispone de una conexión a tierra del sistemaque conecta los componentes del bastidor a los terminalesde tierra de los enchufes hembra de salida de CA. La tierradel sistema está conectada al cable de CA neutro que, a suvez, está conectado al bastidor del generador (el ...
Page 35 - Juegos de cordones y enchufes conectores; Toma eléctricas dobles de 120 V CA y 20 A
Juegos de cordones y enchufes conectores Utilice exclusivamente cables prolongadores de alta calidad,bien aislados y con conexión a tierra para la toma doble de120 V del generador. Examine los cables prolongadoresantes de cada uso. Revise las capacidades de todos las cordones de extensiónantes de us...
Page 36 - Operando; Encienda el motor
Operando Encienda el motor Desconecte todas las cargas eléctricas del generador. Uselas siguientes instrucciones para encender: 1. Asegúrese de que la unidad está en una superficie plana. IMPORTANTE: Si la unidad no se arranca y utiliza en una superficie plana, se pueden producir problemas de arranq...
Page 37 - Conexión de cargas eléctricas; sobrecargar el generador; Parada del motor; todas
13 Español Conexión de cargas eléctricas 1. Deje que el motor se estabilice y se caliente por dos minutos después del arranque. 2. Enchúfelo y encienda la carga eléctrica deseada (120 y/o 240 V CA, monofásico, 60 Hz.) IMPORTANTE: • NO conectar cargas de 240 V en las tomas eléctricas dobles. • NO con...
Page 38 - No sobrecargar el generador; Capacidad
14 BRIGGSandSTRATTON.COM No sobrecargar el generador Capacidad Debe asegurarse de que su generador puede proveer lossuficientes vatios de potencia continua (vatiaje nominal) yvatios de salida para los elementos que desee alimentar almismo tiempo. Siga estos sencillos pasos: 1. Seleccione los element...
Page 39 - Plan de mantenimiento; Recomendaciones generales; Programa de; Control de emisiones; Garantía de emisiones; Mantenimiento del generador
15 Español Mantenimiento Plan de mantenimiento Siga los intervalos de horas o de calendario, los que sucedanantes. Si opera en condiciones adversas (señaladas másabajo) es necesario un mantenimiento más frecuente. 1 Servicio más a menudo bajo condiciones de suciedad o polvo. Recomendaciones generale...
Page 40 - Mantenimiento del motor; Comprobación del nivel de aceite
16 BRIGGSandSTRATTON.COM Mantenimiento del motor Aceite Recomendaciones sobre el aceite Para obtener el mejor rendimiento, recomendamos utilizaraceites certificados con garantía Briggs & Stratton. Tambiénse pueden utilizar otros aceites detergentes de alta calidadcon clasificación de servicio SF...
Page 41 - Servicio del depurador de aire; Especificaciones; Limpie la pantalla apagachispas
17 Español 3. Limpie la zona de alrededor del tapón de vaciado de aceite ( A ), situado en la base del motor, al otro lado del carburador. 4. Quite el tapón de llenado de aceite y vacíe todo el aceite en un recipiente adecuado. 5. Vuelva a colocar el tapón de vaciado y apriételo bien. Quite el tapón...
Page 42 - Comprobación de holgura de la válvula; Plan de Mantenimiento; Ajuste del carburador
18 BRIGGSandSTRATTON.COM Limpie e inspeccione el apagachispas de la siguientemanera: 1. Para retirar la protección del silenciador ( A ) de silenciador ( B ), retire los cuatro tornillos que conectan la protección a la ménsula del silenciador. 2. Retire los cuatro tornillos que sostienen la pantalla...
Page 43 - Almacenamiento; Generador; Limpieza; Almacenamiento para periodos prolongados; lmacenamiento Para Periodos Prolongados
19 Español Almacenamiento El generador deberá ser encendido al menos una vez cadasiete días y deberá dejarlo funcionar al menos durante30 minutos. Si no puede hacer esto y debe almacenar launidad por más de 30 días, siga las siguientes instruccionespara preparar su unidad para almacenamiento. Genera...
Page 44 - Resolución de problemas; Problemo; No Sobrerecarque Generador
20 BRIGGSandSTRATTON.COM Resolución de problemas Problemo Causa Accion El motor está funcionandopero no existe salida de ACdisponsible. 1. El interruptor automático de circuito está abierto. 2. Conexión mal o defectuosa del juego de cables. 3. El dispositivo conectado está dañado. 4. Avería en el ge...
Page 45 - Garantías; Garantía del sistema de control de emisiones; Responsabilidades de la garantía del propietario
21 Español Garantías Garantía del sistema de control de emisiones Briggs & Stratton Corporation (B&S), el California AirResources Board (CARB, Consejo de recursos de aire deCalifornia) y la United States Environmental ProtectionAgency (U.S. EPA, Agencia estadounidense de proteccióndel medioa...
Page 46 - Información sobre emisiones; Período de Durabilidad de las Emisiones
22 BRIGGSandSTRATTON.COM e. Elementos diversos utilizados en los sistemas anteriores • Válvulas y conmutadores de aspiración,temperatura, posición y temporizados • Conectores y unidades 2. Duración de la cobertura B&S garantiza al propietario inicial y a cada compradorposterior que las piezas ga...
Page 48 - Especificaciones del producto
24 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC 900 N. Parkway Jefferson, Wisconsin, 53549 U.S.A. Generador portátil Potencia nominal: El valor de potencia bruta de cada modelo de motor de gasolina se indica en la etiqueta conforme a los requisitos del código J1940 (Procedim...