Page 2 - TABLE OF CONTENTS; Hazard Symbols and Meanings; SAVE THESE INSTRUCTIONS
2 PowerBOSS™ 4500W Portable Generator SAFETY RULES TABLE OF CONTENTS Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 3 - WARNING
3 SAFETY RULES 4500W Portable Generator PowerBOSS™ • This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications. • Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/orproperty damage....
Page 5 - KNOW YOUR GENERATOR
5 FEATURES AND CONTROLS 4500W Portable Generator PowerBOSS™ KNOW YOUR GENERATOR Read this Operator’s Manual and safety rules before operating your generator.Compare the illustrations with your generator to familiarize yourself with the locations of various controls andadjustments. Save this manual f...
Page 6 - ASSEMBLY; Unpacking the Generator; CAUTION
6 PowerBOSS™ 4500W Portable Generator ASSEMBLY ASSEMBLY Your generator requires some assembly and is ready foruse after it has been properly serviced with therecommended oil and fuel. If you have any problems with the assembly of yourgenerator, please call the generator helpline at1-800-743-4115. If...
Page 7 - Return generator to normal operating position (resting; BEFORE STARTING THE; Add Engine Oil; • Place generator on a level surface.; Add Fuel; Type of Fuel; Clean area around fuel fill cap, remove cap.
7 ASSEMBLY 4500W Portable Generator PowerBOSS™ 9. Attach support leg using two short (M8 x 20mm) capscrews and two locking hex nuts. Tighten with a 13mmsocket and wrench. 10. Return generator to normal operating position (resting on wheels and support leg). BEFORE STARTING THE ENGINE Add Engine Oil ...
Page 8 - USING THE GENERATOR; Special Requirements; Exhaust Port
8 PowerBOSS™ 4500W Portable Generator OPERATION USING THE GENERATOR System Ground The generator has a system ground that connects thegenerator frame components to the ground terminals onthe AC output receptacles. The system ground is connectedto the AC neutral wire (the neutral is bonded to thegener...
Page 9 - OPERATING THE; Starting the Engine; Make sure unit is on a level surface.; Connecting Electrical Loads; • Let engine stabilize and warm up for a few minutes after; AND
9 OPERATION 4500W Portable Generator PowerBOSS™ OPERATING THE GENERATOR Starting the Engine Disconnect all electrical loads from the generator. Use thefollowing start instructions: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate unit on a levelsurface will cause the ...
Page 10 - Stopping the Engine; DANGER
10 PowerBOSS™ 4500W Portable Generator OPERATION • DO NOT connect 50 Hz loads to the generator. • DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload Generator”. Stopping the Engine 1. Turn OFF and unplug all electrical loads from generatorpanel receptacles. NEVER start or stop engine withelectrical ...
Page 11 - RECEPTACLES; Receptacle
11 OPERATION 4500W Portable Generator PowerBOSS™ NOTE: Use an automotive hydrometer to test battery stateof charge and condition. Follow the hydrometermanufacturer’s instructions carefully. Generally, a battery isconsidered to be at 100% state of charge when specific gravityof its fluid (as measured...
Page 12 - Ground Fault Protection; Test your GFCI outlet prior to each use, as follows:; • Push the black “Test” button. The red “Reset” button; • If the GFCI tests good, restore power by pressing the; Generator produces hazardous voltage/current.
12 PowerBOSS™ 4500W Portable Generator OPERATION Ground Fault Protection The duplex receptacles are equipped with Ground FaultCircuit Interrupter (GFCI) protection. This device meetsapplicable federal, state and local codes. The generator’slocking receptacle is not protected by a GFCI. The GFCI prot...
Page 13 - COLD WEATHER
13 OPERATION 4500W Portable Generator PowerBOSS™ COLD WEATHER OPERATION Under certain weather conditions (temperatures below40°F [4°C] combined with high humidity), your generatormay experience icing of the carburetor and/or thecrankcase breather system. To reduce this problem, youneed to perform th...
Page 14 - GENERATOR; Capacity
14 PowerBOSS™ 4500W Portable Generator OPERATION DON'T OVERLOAD GENERATOR Capacity You must make sure your generator can supply enoughrated (running) and surge (starting) watts for the items youwill power at the same time. Follow these simple steps:1. Select the items you will power at the same time...
Page 15 - SPECIFICATIONS; Engine Maintenance; See engine operator’s manual for instructions.; Maintenance Minder
15 MAINTENANCE 4500W Portable Generator PowerBOSS™ SPECIFICATIONS Starting Wattage . . . . . . . . . . . . . . . . . . . . . . .5,625 wattsWattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,500 wattsAC Load Current: At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .37.5 ...
Page 16 - STORAGE; Storage covers can be flammable.
16 PowerBOSS™ 4500W Portable Generator STORAGE Generator Cleaning • Use a damp cloth to wipe exterior surfaces clean. • Use a soft bristle brush to loosen caked on dirt or oil.• Use a vacuum cleaner to pick up loose dirt and debris.• Inspect cooling air slots and opening on generator. These openings...
Page 17 - TROUBLESHOOTING; Problem; Generator lacks power.
17 TROUBLESHOOTING 4500W Portable Generator PowerBOSS™ TROUBLESHOOTING Problem Cause Correction No AC output is available, butgenerator is running. 1. One of the circuit breakers isopen. 2. Fault in generator. 3. Poor connection or defective cordset. 4. Connected device is bad. 1. Reset circuit brea...
Page 18 - NOTES
Page 19 - LIMITED WARRANTY; ABOUT YOUR WARRANTY; WARRANTY PERIOD
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that isdefective in material or workmanship or both. Transportation ...
Page 20 - PowerBOSSTM; 500 Watt Generador Portátil; REGLAS DE SEGURIDAD; TABLA DE CONTENIDOS; Símbolos de Peligro y Significados; ADVERTENCIA; CONSERVE ESTAS INSTRUCCIONES
PowerBOSS™ 4500 Watt Generador Portátil REGLAS DE SEGURIDAD 20 TABLA DE CONTENIDOS Reglas De Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22Características y Controles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Montaje . . . . . . . . . . . . . . . . ...
Page 23 - CARACTERÍSTICAS Y CONTROLES; POWERBOSSTM; CONOZCA SU GENERADOR
CARACTERÍSTICAS Y CONTROLES 4500 Watt Generador Portátil POWERBOSS™ 23 CONOZCA SU GENERADOR Lea este Manual del Operario y las reglas de seguridad antes de operar su generador.Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes.Con...
Page 24 - MONTAJE; Desembalaje del Generador; PRECAUCIÓN
PowerBOSS™ 4500 Watt Generador Portátil MONTAJE 24 MONTAJE Su generador requiere de ciertos procedimientos de montaje ysolo estará listo para ser utilizado después de haberlesuministrado servicio con el combustible y aceite recomendados. Si usted tiene problemas con el montaje de su generador, por f...
Page 25 - ANTES DE DARLE ARRANQUE AL; Agregar Aceite al Motor; Agregue Combustible
MONTAJE 4500 Watt Generador Portátil PowerBOSS™ 25 ANTES DE DARLE ARRANQUE AL MOTOR Agregar Aceite al Motor • Coloque la generador sobre una superficie nivelada. • Consulte el manual del operario del motor para añadir almotor el aceite recomendado. NOTA: Verifique el aceite del motor de manerafrecue...
Page 26 - OPERACIÓN; USO DEL GENERADOR; Tierra del Sistema; Conexión al Sistema Eléctrico de un
PowerBOSS™ 4500 Watt Generador Portátil OPERACIÓN 26 USO DEL GENERADOR Tierra del Sistema El generador dispone de una conexión a tierra del sistema queconecta los componentes del bastidor a los terminales de tierrade los enchufes hembra de salida de CA. La tierra del sistemaestá conectada al cable d...
Page 27 - OPERANDO EL GENERADOR; Encienda el Motor; Conexion De Cargas Electricas
27 OPERANDO EL GENERADOR Encienda el Motor Desconecte todas las cargas eléctricas del generador. Use lassiguientes instrucciones para encender:1. Asegúrese de que la unidad está en una superficie plana. IMPORTANTE: Si la unidad no se arranca y utiliza en unasuperficie plana, se pueden producir probl...
Page 28 - Parado Del Motor; Funcionamiento del Control Automatico; PELIGRO
PowerBOSS™ 4500 Watt Generador Portátil OPERACIÓN 28 • NO conecte cargas de 50 Hz al generador. • NO SOBRECARGUE EL GENERADOR. Vea "NoSobrecargue Generador". Parado Del Motor 1. Desconecte todas las cargas eléctricas de los tomacorrientesdel panel del generador. NUNCA de arranque o detenga e...
Page 29 - RECEPTÁCULOS; de Seguridad
OPERACIÓN 4500 Watt Generador Portátil PowerBOSS™ 29 8. Apague el motor cuando la batería se haya cargado. NOTA: Use un hidrómetro para automóviles para probar elestado de carga y condición de la batería. Siga cuidadosamente lasinstrucciones del fabricante del hidrómetro. Por lo general, seconsidera...
Page 31 - OPERACIÓN DURANTE UN; Creación de una Clima Frío Estructura de
OPERACIÓN 4500 Watt Generador Portátil PowerBOSS™ 31 OPERACIÓN DURANTE UN CLIMA FRÍO En ciertas condiciones climáticas (temperaturas inferiores a 4 º C [40 º F] combinadas con un alto nivel de humedad), su generador puede experimentar formación de hielo en el carburador o elsistema de ventilación de...
Page 32 - NO SOBRECARGUE GENERADOR; Capacidad; Control de la Energía
PowerBOSS™ 4500 Watt Generador Portátil OPERACIÓN 32 NO SOBRECARGUE GENERADOR Capacidad Usted debe asegurarse que su generador puede proveer elsuficiente vataje calificado (cuando esté funcionando) y de carga(al encender) para los aparatos a los cuales va a proveer laenergía, al mismo tiempo. Siga e...
Page 33 - Mantenimiento del Motor; MANTENIMIENTO
33 ESPECIFICACIONES Vataje que empieza. . . . . . . . . . . . . . . . . . . . 5,625 Vatios (5.6 kW) Vataje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,500 Vatios (4.5 kW) Corriente valorada de Carga de C.A.: a 240 Voltios. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18....
Page 34 - ALMACENAMIENTO; Almacenando el Generador
PowerBOSS™ 4500 Watt Generador Portátil ALMACENAMIENTO 34 Para Limpiar el Generador • Utilice un trapo húmedo para limpiar las superficiesexteriores. • Puede usar un cepillo de cerdas suaves para retirar la suciedadendurecida, aceite, etc. • Puede usar una máquina aspiradora para eliminar suciedad y...
Page 35 - DIAGNOSITICOS DE AVERÍAS; Problemo
DIAGNOSITICOS DE AVERÍAS 4500 Watt Generador Portátil PowerBOSS™ 35 DIAGNOSITICOS DE AVERÍAS Problemo Accion Causa El motor está funcionando pero noexiste salida de AC disponsible. 1. El interruptor automático de circuitoestá abierto. 2. Conexión mal o defectuosa del juegode cables. 3. El dispositiv...
Page 36 - GARANTÍA LIMITADA; ACERCA DE LA EQUIPO GARANTÍA
Esperamos que disfrute de nuestra garantía y le pedimos disculpas por las molestias causadas. Cualquier distribuidor de servicio autorizado puede llevar acabo reparaciones en garantía. La mayoría de las reparaciones en garantía se gestionan normalmente, pero algunas veces la solicitud de servicio en...