Page 2 - DESCRIPTION OF THE HOT PLATES
2 Natural U-LPG 1 Ultra rapid gas burner of 11.9 MJ 11.9 MJ 2 Semirapid gas burner of 6.3 MJ 6.3 MJ 3 Auxiliary gas burner of 3.6 MJ 3.6 MJ 4 Cast iron trivet 1 burner5 Cast iron trivet 2 burner6 Cast iron trivet 3 burner7 Burner control knobs Attention: this appliance has been manufactured for dome...
Page 3 - USE
3 1) BURNERS A diagram is screen-printed above each knob on thefront panel. This diagram indicates to which burnerthe knob in question corresponds. After havingopened the gas mains or gas bottle tap, light theburners as described below:- Manual ignitionP u s h a n d t u r n t h e k n o b c o r r e s...
Page 5 - CLEANING
5 CLEANING IMPORTANT:Always disconnect the appliance from the gasand electricity mains before carrying out anycleaning operation. 2) HOT PLATE Periodically wash the hot plate, the cast iron pansupport, the enamelled burner caps “C” and theburner heads “M” (see fig. 6) with lukewarm soapywater. Follo...
Page 6 - ) INSTALLING THE HOT PLATE; INSTALLATION
6 TECHNICAL INFORMATION FOR THE INSTALLER This appliance shall be installed only by authorisedpersonnel and in accordance with the manufacturer’sinstallation instructions, local gas fitting regulations,municipal building codes, water supply regulations,electrical wiring regulations, AS 5601/AG 601 –...
Page 7 - ) LOCATION AND VENTILATION
5) LOCATION AND VENTILATION Ventilation must be in accordance with AS5601/AG 601 – Gas Installations. In general, the appliance should have adequate ventilation forcomplete combustion of gas, proper flueing and to maintaintemperature of immediate surroundings within safe limits.The wall and bench su...
Page 8 - ) ELECTRICAL CONNECTION
8 INSTALLATION 7) ELECTRICAL CONNECTION The appliance is supplied with a 1800 mm longflexible supply lead.The point of attachment for this lead is located atthe rear and on the underside of the appliance380 mm from the right hand side.The voltage and power consumption are detailed onthe underside of...
Page 9 - ADJUSTMENTS
9 A l w a y s d i s c o n n e c t t h e a p p l i a n c e f r o m t h eelectricity main before making any adjustments.All seals must be replaced by the technician atthe end of any adjustments or regulations.O u r b u r n e r s d o n o t r e q u i r e p r i m a r y a i radjustment. 8) TAPS Our taps a...
Page 10 - CONVERSIONS
10 9) U-LPG TO NATURAL GASCONVERSION PROCEDURE A p p l i a n c e m o d e l s : G a s c r y s t a l g l a s s h o t p l a t emodels: BCGC74 4 BurnersBCGC52 2 Burners 1. Remove each burner cap and burner skirt. 2 . R e m o v e t h e U - L P G m a i n i n j e c t o r w i t h a 7 m m / V F t u b e s p a...
Page 11 - BURNER ARRANGEMENT ON THE HOT PLATE
11 CONVERSIONS FIG. 14 BURNER ARRANGEMENT ON THE HOT PLATE U-LPG 2.75 95 11.9 NATURAL 1.00 155 11.9 U-LPG 2.75 70 6.3 NATURAL 1.00 112 6.3 BURNERS N° DESCRIPTION GAS NORMAL PRESSURE INJECTOR DIAMETER NOMINAL HEAT INPUT (MJ/h) (kPa) (1/100 mm) MAX. TABLE U-LPG 2.75 53 3.6 NATURAL 1.00 85 3.6 1 ULTRA ...
Page 12 - SERVICING; 1) COMPONENTS REPLACEMENT
12 SERVICING WARNING:A l w a y s d i s c o n n e c t t h e a p p l i a n c e f r o m t h eelectricity and gas mains before proceedingwith any servicing operation.S e r v i c i n g s h o u l d b e c a r r i e d o u t o n l y b yauthorised personnel. 11) COMPONENTS REPLACEMENT NOTE:B E F O R E A N Y M...
Page 13 - CABLE TYPES AND SECTIONS
13 SERVICING TYPE OF TYPE OF SINGLE - PHASE HOT PLATE CABLE POWER SUPPLY CABLE TYPES AND SECTIONS ATTENTION!!!If the power supply cable is replaced, the installer should leave the ground wire longer than the phaseconductors (fig. 21) and comply with the recommendations given in paragraph 8. FIG. 21 ...
Page 14 - TECHNICAL ASSISTANCE AND SPARE PARTS; MEA – BLANCO
TECHNICAL ASSISTANCE AND SPARE PARTS MEA – BLANCO TECHNICAL ASSISTANCE AND SPARE PARTS 14 NEW SOUTH WALES Head Office, Sales & Marketing Office 104 Vanessa Street Kingsgrove NSW 2208 Telephone: 02 9503 2888 Facsimile: 02 9503 2810 NSW Showroom*40 Ebley Street Bondi Junction NSW 2022 Telephone: 0...