Page 3 - MPORTANT SAFETY INSTRUCTIONS; To reduce the risk of fire,; SAVE THESE
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 I MPORTANT SAFETY INSTRUCTIONS 3 When using an electrical appliance, basic precautions should be observed, including the following: Read all instRuctions befoRe using upRight VacuuM always connect to a polarized outlet (left slot is wider than ri...
Page 4 - roduct view
Power Cord w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 4 P roduct view WARNING: Plastic film can be dangerous. To avoid danger of suffocation, keep away from babies and children. CAUTION: Do not plug in your vacuum cleaner until you are familiar with all instructions and operating procedur...
Page 5 - ssembly; Hose; The only tool you’ll need to assemble; Attach handle to vacuum; NOTE: The Powerfoot will not
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 A ssembly 5 2. 2. Hose Wand Base The only tool you’ll need to assemble your vacuum cleaner is a Philips head screwdriver. Attach handle to vacuum 1. locate the vacuum handle and remove the screw packet taped to the base of the handle. 2. stand th...
Page 6 - perations; Handle position; Press the handle release pedal with your; Height adjustment; There are five height settings available; Transporting cleaner; to move your cleaner from room to room,
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 O perations 6 Handle position Press the handle release pedal with your foot to place your CleanView Helix into one of three cleaning positions.1. Upright – for storage and above floor cleaning with tools. 2. Normal cleaning – press handle release...
Page 7 - Air flow indicator; Combination dusting
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 7 O perations Air flow indicator (select models only) The air flow indicator tells you when airflow in the vacuum is reduced due to a clog in the hose. The indicator will remain green until the airflow is reduced. When it is fully red, the airflo...
Page 8 - Power cord storage; ing or replacing may be necessary; Empty Dirt Container; Full Line; aintenance and care
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 O perations 8 Power cord storage When you have finished using your BISSELL CleanView Helix, return it to the upright position and store the power cord.1. turn vacuum cleaner off. 2. unplug power cord by grasping the polarized plug (not the cord) ...
Page 9 - Empty Dirt Container continued; Use only genuine BISSELL style; Cleaning the inner & outer circular filter
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 9 M aintenance and care Empty Dirt Container continued 5. put the dirt container back in the vacuum and slide the lever to the "lock" position. Note: The dirt container may be washed in warm water with a mild detergent. Make sure it is co...
Page 10 - Cleaning the pre-motor filter; Note: A basic washable; Checking rotating floor brush and drive belt
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 M aintenance and care 10 Cleaning the pre-motor filter 1. unplug the cleaner from electrical outlet. 2. the pre-motor filter protects the motor from debris. it is located underneath the filter cup in the center of the round part of the lock ‘n se...
Page 11 - Replace drive belt; Use only genuine BISSELL style 9; Checking rotating floor brush and drive belt continued
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 11 M aintenance and care . 5. clean strings, hair and other debris from rotating floor brush, paying particular attention to brush ends. 6. clean strings, hair and other debris from motor pulley and drive belt areas. 7. check drive belt carefully...
Page 12 - Clearing a clog; Low suction or poor pickup may be
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 12 Clearing a clog Low suction or poor pickup may be due to a clog in the vacuum cleaner. If you notice a change in the sound of the motor or a reduction in the spinning action, check for clog...
Page 13 - roubleshooting - CleanView Helix
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 13 Vacuum cleaner won’t turn on Possible causes Remedies 1. Power cord not plugged in 1. Check electrical plug 2. Blown fuse/tripped breaker 2. Check/replace fuse or reset breaker Vacuum cleaner won’t pick up dirt Possible causes Remedies 1. Inco...
Page 14 - eplacement Parts - CleanView Helix; ccessories - CleanView Helix; Item Part No. Part Name
R eplacement Parts - CleanView Helix ® Item Part No. Part Name 1 32074 style 9 drive belt (2-pack) 2 203-2450 hose assembly 3 203-2448 brush dowel (13.5") 4 32R9 style 16 inner and outer circular pre-Motor filter 5 set 73K1 style 16 inner circular pre-Motor filter set 6 69b1 style 16 outer circu...
Page 15 - arranty - BISSELL CleanView Helix; Limited One Year Warranty; If your BISSELL product should require service:; your warranty, contact bissell consumer services.
w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1 15 W arranty - BISSELL CleanView Helix ® 95P1 and 82H1 this warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. if you need additional instruction regarding this warranty or have questi...
Page 16 - BISSELL Consumer Services; Or visit the BISSELL website -; NOTE: Please keep your original sales receipt. It; ISSELL consumer services; BISSELL Rewards Points; questions regarding your product.; Product Support Reminders and Alerts
For information about repairs or replacement parts, or questions about your warranty, call: BISSELL Consumer Services 1-800-237-7691 Monday - Friday 8 a.m. — 10 p.m. ETSaturday 9 a.m. — 8 p.m. ET Or write: BISSELL Homecare, Inc. PO Box 3606 Grand Rapids MI 49501ATTN: Consumer Services Or visit the B...