Page 2 - Instruction Manual; Hazard definitions
2 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Please . . . read this page first Hazard definitions The following will be used throughout this manual to bring attention to hazards and their risk factors, or to special information. D e n o t e s p r e s e n c e o f a h a z a r ...
Page 3 - Contents; Warranty; Agency approvals
3 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Contents Please . . . read this page first ................ 2 Pre-installation checklist ........................... 4 Mount the burner .......................................... 6 Connect fuel line(s) ...............................
Page 4 - Pre-installation checklist; If fuel supply is; level with or higher than; fuel unit —; f fuel supply is; below; the fuel unit —; Table 1 - Nozzle capacitites
4 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Pre-installation checklist ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com-bustion air openings comply with National Fire ProtectionStand...
Page 5 - Figure 1 - Min. Combustion chamber dimensions; Table 2 - Air tube capacity vs. firebox pressure; Verify firing rate; Verify air tube
5 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 1 - Min. Combustion chamber dimensions 1405 A L Figure 2 - Air tube mounting dimensions E T D 2° 1404 G 1 E Insertion depth G Air tube to inside of chamber– 0.25" ± 0.125" T Air tube length D Tube diameter ① Install...
Page 6 - Mount the burner; Figure 4 - Nozzle and nozzle line assembly; Mount air tube to burner
6 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Mount the burner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges.• Do not install air tube on burner.• For non-pressure firing flange, refer to Figure 3 : Install gasket (item a ) and fla...
Page 7 - Figure 5 - Nozzle line assembly in burner; Figure 7 - Burner installed in appliance front; Legend; Set dimension Z; once again. Loosen acorn nut; do not loosen acorn nut; Insert burner; inches less than dimension
7 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 5 - Nozzle line assembly in burner Z 1408 a Measure dimension from front (flat) face of head toend of air tube, as shown. Z b c d Measure dimension Z from the flatsurface between (not on) the raised fins. 1424 Figure 7 - Bu...
Page 8 - Fuel unit by-pass plug; Oil supply/return lines; Figure 8a – One-pipe oil flow with “H” pump
8 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner I n s t all the oil lines us ing the fol l owi ngguidelines. Failure to comply could lead toequipment damage and present a risk of severepersonal injury, death or substantial propertydamage due to leakage of oil and potentialfire ...
Page 9 - Figure 9a – Two-pipe oil flow with “H” pump; Table 3 – Fuel unit gearset capacities; Burner fuel flow
9 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 9a – Two-pipe oil flow with “H” pump 300 psig k g 1413ao d a b p 300 psig c Figure 9b – Two-pipe oil flow with “B” pump d b g p 300 psig 300 psig c 1423ao a k a Return port b Nozzle port c Oil valve d Nozzle & adapter L...
Page 10 - Wire the burner; in accordance with the appliance manufacturer's guidelines.; Figure 10 – Typical wiring; PR
10 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Wire the burner Install the burner and all wiring in accordance with theNational Electrical Code and all applicable local codes orrequirements. Wire the burner in compliance with all instructions providedby the appliance manufact...
Page 11 - Sequence of operation — typical; Prepare the burner for start-up
11 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Sequence of operation — typical 1. On call for heat from the appliance operating controls (and the circuit from T to T of the R8184 closed), power is applied to the R8184 black wire ( BK ). 2. The R8184 applies 120 volts to the o...
Page 12 - Z dimension; Initial air settings; Figure 11 – Adjusting plate initial setting, typical; Table 4 – Initial indicator adjustment plate settings
12 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Prepare the burner for start-up - continued ❏ Z dimension • Should be set per these instructions (see page 7). The top acorn nut ( Figure 11 , item d ) should never be loosened once the Z dimension is initially set. ❏ Adjusting p...
Page 13 - Figure 12 – Air damper assembly; Set appliance limit controls; • Set the appliance limit controls in accordance with the; Prepare the fuel unit for air venting; • To vent air from one-pipe oil systems, attach a clear hose to
13 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 12 – Air damper assembly Table 5 – Initial air adjusting plate settings (damper position) 12 0 1 2 3 4 5 6 7 8 9 10 11 1409o-2 h k m Legend (Figure 12) h Damper label - position indicator for air adjusting plate k Damper i...
Page 14 - Starting the burner and venting air
14 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Start the burner Do not proceed unless all prior steps in thismanual have been completed. Failure tocomply could result in severe personal injury,death or substantial property damage. Do not attempt to start the burner when exces...
Page 15 - Set air adjusting plate; Maintenance and service; Monthly maintenance; Annual service
15 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner ❏ Set air adjusting plate ( Figure 12 ) 1. Allow the burner to run until the appliance has warmed sufficiently. 2. Visually check the flame. The flame should not be dark orange or smoky.If the flame appears to be smoking, increas...
Page 16 - Replacement parts; Figure 13 – Adjustable mounting plates for CF1400
U.S.A.: P. O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • FAX 440-327-1064 Canada: R. W. Beckett Canada, Ltd. • 430 Laird Road • Guelph, Ontario, N1G 3X7 • 800-665-6972 • FAX 519-763-5656 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Replacement parts 1 2 3 9 ...