Manual 2100-498B Page 2 of 17 CONTENTS General General Information ................................................. 3Unpacking ................................................................ 3Description ............................................................... 3Models .........................
Page 3 - GENERAL; GENERAL INFORMATION; Because of this, all units; UNPACKING; TABLE 1
Manual 2100-498BPage 3 of 17 GENERAL GENERAL INFORMATION The ventilator should only be installed by a trainedheating and air conditioning technician. Theseinstructions serve as a guide to the technician installingthe ventilator package. They are not intended as a stepby step procedure with which the...
Page 4 - INSTALLATION; BASIC INSTALLATION; Unpack the ventilator assembly which includes the; WARNING; FIGURE 1
Manual 2100-498BPage 4 of 17 INSTALLATION BASIC INSTALLATION 1. Unpack the ventilator assembly which includes the integral ventilator with attached electrical harness,blank-off plate and miscellaneous hardware. 2. Remove and save the existing exterior blower access and service access panels (see Fig...
Page 5 - FIGURE 2 INSET; Install ventilator sheet metal assembly by inserting
Manual 2100-498BPage 5 of 17 FIGURE 2 INSTALLATION OF ECONOMIZER FIGURE 2 INSET SIDE SECTION 5. Install ventilator sheet metal assembly by inserting the ventilator into the unit – centering between thetubing on the left and the control panel on the right.Once the ventilator is fully inserted, slide ...
Page 6 - PLUG TO
Manual 2100-498BPage 6 of 17 FIGURE 3 INSTALL LOOSE PIECE WIRE HARNESS PLUG SECURE INTO FILTER TRAY PLUG TO ROUTE WIRES THROUGHWIRE MOUNT, AND INTO HOLE AT REAR OF UNITINTO LOW VOLTAGE TERMINAL BLOCK AREA MIS-2415
Page 7 - DANGER
Manual 2100-498BPage 7 of 17 9. Mount mixed air thermistor sensor to blower as shown with screws provided. Route two (2) redwires from wire harness installed in Step #7 throughcable holders, and connect to thermistor sensor asshown in Figure 2. 10. Connect the wires (with fork connectors) routed int...
Page 11 - WG5S Ventilation Airflow
Manual 2100-498BPage 11 of 17 WG5S Ventilation Airflow 0 100 200 300 400 500 600 700 800 900 1000 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 Vent Position Ventilation Airflow (CFM) Stage #2 Operation Stage #1 Operation Blower Only
Page 12 - W24G EIFM Airflow Versus Position - Low Speed; W24G EIFM Airflow Versus Position - Medium; W24G EIFM Airflow Versus Position - High Speed
Manual 2100-498BPage 12 of 17 0 50 100 150 200 250 300 350 400 450 500 550 600 closed A B C D Open Damper Position W24G EIFM Airflow Versus Position - Low Speed Free Blow.15" ESP.30" ESP 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 closed A B C D Open Damper Position W24G EIFM Ai...
Page 13 - W30-36G EIFM Airflow Versus Position - Low Speed; W30-36G EIFM Airflow Versus Position - Medium; W30-36G EIFM Airflow Versus Position - High
Manual 2100-498BPage 13 of 17 0 50 100 150 200 250 300 350 400 450 500 550 600 650 closed A B C D Open Damper Position W30-36G EIFM Airflow Versus Position - Low Speed Free Blow.15" ESP.30" ESP 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 closed A B C D Open Damper Position W...
Page 14 - W42-60G EIFM Airflow Versus Position - Low Speed; W42-60G EIFM Airflow Versus Position - Medium; W42-60G EIFM Airflow Versus Position - High
Manual 2100-498BPage 14 of 17 0 50 100 150 200 250 300 350 400 450 500 550 600 650 closed A B C D Open Damper Position W42-60G EIFM Airflow Versus Position - Low Speed Free Blow0.15" ESP0.30" ESP 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 closed A B C D Open Damper Posi...